101 resultados para Faria, Almeida, 1943-


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The identification and treatment of peri-implant infections are an essential stage in the maintenance of dental implants, reflecting the longevity of rehabilitation. Therefore, the aim of the study was to conduct a literature review addressing peri-implantitis in dental implants in order to guide planning for the longevity of oral rehabilitation. It was conducted a detailed search strategy by the PubMed / Medline Dentistry and Oral Science, it was used as descriptors: “peri-implantitis” and “Dental Implant”, until July 2013. From 566 articles, after a review, according to the inclusion criteria, 34 articles were selected. The results were grouped together in topics (concept, etiology, diagnosis, surgical and nonsurgical, and aspects of oral rehabilitation) for further discussion and conclusions. Conclusions: The accumulation of plaque has been associated with a higher propensity to peri-implantitis. There is a higher incidence of the peri-implantitis disease among patients with previous history of periodontal disease. The local administration of antibiotics and association with mouthwashes / topical use are indicated as suitable for the treatment of moderate peri-implantitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to analyze the biomechanical interactions in bone tissue between short implants and implant-supported crowns with different heights. Two models were made using the programs InVesalius 3.0, Rhinoceros 4.0 and Solidworks 2010. The models were established from a bone block with the short implant (3.75 x 8.5 mm) with geometry Morse taper connection (MT). The height of the crown (cemented) was set at 10.0 mm and 15.00 mm. The models were processed by programs and 10 NEiNastran Femap 10.0. The force applied was 200N (vertical) and 100N (oblique). The results were plotted on maps Voltage Maximum Principal. Statistical analysis was performed using ANOVA. The results showed that the increase in crown height, increased stress concentration in the crown of 15 mm under oblique loading (p <0.001), the oblique loading has significantly expanded the area of stress concentration (p <0.001). Conclusion:the increase of the crown increased the stress concentration, being statistically significant for short implants Morse taper. The mesial and distal region had the highest concentration of stresses under oblique loading. The oblique loading was more harmful when compared with axial loading, being statistically significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of implants of greater length may be more favorable for the predictability of dental implants. This statement is relevant, since the cause of failures in dental implants are more related to biomechanical complications. The aim of this study was to evaluate the influence of increase of the length around the entire body of the implant. Six models were created with the presence of only one hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 7.0 mm (Model A), 3.75 mm x 8.5 mm (Model B ), 3.75 mm x 10.0 mm (Model C) 3.75 mm x 11.5 mm (Model D) 3.75 mm x 13.0 mm (Model E) 3.75 mm x 15.0 mm (Model F) using the method of photoelasticity. The results were visualized through a qualitative analysis of stresses (number and intensity photoelastic fringes). The model A showed a pattern of less favorable stress distribution, the oblique loading was the most detrimental to the related structures. Conclusion: The increased length allowed for a better distribution of stresses. The oblique loading was more detrimental when compared to axial loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature has suggested that the association of removable partial dentures with dental implants can improve the quality of life of patients. Thus, the purpose of this study was to present a case report. This case report describes the development of a removable partial denture associated with dental implants bilaterally been monitored for 12 years, and the efficacy of the proposed treatment. The radiographic controls demonstrated no changes on bone tissue. The maxillary arch was rehabilitated with metal-free crowns. The patient was fully satisfied with this technique providing stability, esthetics, and proper function. It was concluded that the technique of using removable partial dentures associated with dental implants is viable and show the advantages of improved function, aesthetics and cost reductions in rehabilitation treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. A large number of patients with chronic hepatitis C have not been cured with interferon-based therapy. Therefore, we evaluated the efficacy of amantadine combined with the standard of care (pegylated interferon plus ribavirin) in patients who had not responded to or had relapsed after 24 weeks of treatment with conventional interferon plus ribavirin. Material and methods. Patients stratified by previous response (i.e., non-response or relapse) were randomized to 48 weeks of open-label treatment with peginterferon alfa-2a (401(D) 180 pg/week plus ribavirin 1,000/1,200 mg/day plus amantadine 200 mg/day (triple therapy), or the standard of care (peginterferon alfa-2a [40KD] plus ribavirin). Results. The primary outcome was sustained virological response (SVR), defined as undetectable hepatitis C virus RNA in serum (< 50 IU/mL) at end of follow-up (week 72). Among patients with a previous non-response, 12/53 (22.6%; 95% confidence interval [CI] 12.3-36.2%) randomized to triple therapy achieved an SVR compared with 16/52 (30.8%; 95% CI 18.7-45.1%) randomized to the standard of care. Among patients with a previous relapse 22/39 (56.4%; 95% CI 39.6-72.2%) randomized to triple therapy achieved an SVR compared with 23/38 (60.5%; 95% CI 43.4-76.0%) randomized to the standard of care. Undetectable HCV RNA (< 50 IU/mL) at week 12 had a high positive predictive value for SVR. A substantial proportion of non-responders and relapsers to conventional interferon plus ribavirin achieve an SVR when re-treated with peginterferon alfa-2a (40KD) plus ribavirin. Conclusion. Amantadine does not enhance SVR rates in previously treated patients with chronic hepatitis C and cannot be recommended in this setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatic encephalopathy (HE) is a functional disorder of the central nervous system (CNS) associated with liver failure, either end-stage chronic liver disease or fulminant hepatic failure. Its pathogenesis remains complex and poorly understood. In view of recent advances in the management of HE, the Brazilian Society of Hepatology endorsed a monothematic meeting regarding HE in order to gather experts in the field to discuss related data and to draw evidence-based recommendations concerning: management of HE and intracranial hypertension in FHF, treatment of episodic HE in cirrhosis, controversies in the management of EH including difficult to treat cases and diagnostic and treatment challenges for minimal HE. The purpose of this review is to summarize the lectures and recommendations made by the panel of experts of the Brazilian Society of Hepatology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)