250 resultados para FLATTENED TUBES
Resumo:
Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of a stone index and of 3 impression techniques (tapered impression copings, squared impression copings, and squared impression copings splinted with acrylic resin) associated with 3 pouring techniques (conventional, pouring using latex tubes fitted onto analogs, and pouring after joining the analogs with acrylic resin) for implant-supported prostheses. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutment analogs, a framework, and 2 aluminum custom trays were fabricated. Polyether impression material was used for all impressions. Ten groups were formed (a control group and 9 test groups formed by combining each pouring technique and impression technique). Five casts were made per group for a total of 50 casts and 200 gap values (1 gap value for each implant-abutment analog). Results: The mean gap value with the index technique was 27.07 mu m. With the conventional pouring technique, the mean gap values were 116.97 mu m for the tapered group, 5784 mu m for the squared group, and 73.17 mu m for the squared splinted group. With pouring using latex tubes, the mean gap values were 65.69 mu m for the tapered group, 38.03 mu m for the squared group, and 82.47 mu m for the squared splinted group. With pouring after joining the analogs with acrylic resin, the mean gap values were 141.12 jum for the tapered group, 74.19 mu m for the squared group, and 104.67 mu m for the squared splinted group. No significant difference was detected among Index, squarellatex techniques, and master cast (P > .05). Conclusions: The most accurate impression technique utilized squared copings. The most accurate pouring technique for making the impression with tapered or squared copings utilized latex tubes. The pouring did not influence the accuracy of the stone casts when using splinted squared impression copings. Either the index technique or the use of squared coping combined with the latex-tube pouring technique are preferred methods for making implant-supported fixed restorations with dimensional accuracy.
Resumo:
Low-level laser therapy (LLLT) accelerates tissue repair. Mast cells induce the proliferation of fibroblasts and the development of local fibrosis. The objective of this study was to quantify fibrosis rate and mast cells in connective tissue after endodontic sealer zinc oxide and eugenol (ZOE) was implanted and submitted to LLLT, immediately after implant and again 24 h later. Sixty mice were distributed into three groups: GI, GII, and GIII (n = 20). In GI, the tubes filled with Endofill were implanted in the animals and were not irradiated with LLLT. In GII, the tubes containing Endofill were implanted in the animals and then irradiated with red LLLT (InGaAIP) 685-nm wavelength, D=72 J/Cm(2), E = 2 J, T=58 s, P=35 mW, and in GIII, the tubes with Endofill were implanted and irradiated with infrared LLLT (AsGaAl) 830-nm wavelength, D=70 J/Cm(2), E = 2 J, T=40 s, P=50 mW. After 7 days and 30 days, the animals were killed. A series of 6-mu m-thick sections were obtained and stained with Toluidine Blue and Picrosirius and analyzed under a standard light microscope using a polarized light filter for the quantification of fibrosis. The statistics were qualitative and quantitative with a significance of 5%. The irradiation with LLLT did not offer improvement in the fibrosis rate, however, it provided a significant decrease in the concentration of independent mast cells for the period studied.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Background Tissue adhesives have been widely used for wound closure, especially in children, because they are painless, fast, and easy to use and result in minimal scarring.Objective To analyze the biocompatibility of an adhesive based on n-butyl-cyanoacrylate in the subcutaneous tissue of rats.Materials and Methods Two surgical sites were prepared (approximately 3 cm apart): one on the left side of the animal and the other on the right side); polyethylene tubes were implanted in each surgical site. The tube on the left was filled with n-butyl-cyanoacrylate (treated group) and the tube on the right side was unfilled (control group). After 7, 30, and 120 days, the animals were killed, and the specimens were processed for histologic analysis.Results No significant inflammatory reaction occurred in the treated group, showing results similar to the control group.Conclusion This adhesive based on n-butyl-cyanoacrylate is biocompatible in the subcutaneous tissue of rats.
Resumo:
Objective: Hydroxyl (OH(-)) and calcium (Ca(++)) ion release was evaluated in six materials: G1) Sealer 26, G2) White mineral trioxide aggregate (MTA), G3) Epiphany, G4) Epiphany + 10% calcium hydroxide (CH), G5) Epiphany + 20% CH, and G6) zinc oxide and eugenol. Material and Methods: Specimens were placed in polyethylene tubes and immersed in distilled water. After 3, 6, 12, 24, and 48 h, 7, 14, and 28 days, the water was assessed for pH with a pH meter and for Ca++ release by atomic absorption spectrophotometry. Results: G1, G2, G4, and G5 had the highest pH until 14 days (p < 0.05). G1 presented the highest Ca(++) release until 6 h, and G4 and G5, from 12 h through 14 days. Ca(++) release was greater for G1 and G2 at 28 days. G6 released the least Ca(++). Conclusions: MTA, Sealer 26, Epiphany, and Epiphany + CH release OH-and Ca(++) ions. Epiphany + CH may be an alternative as retrofilling material.
Resumo:
Introduction: An experimental mineral trioxide aggregate sealer (MTAS) has been developed for use as a root canal sealer. The aim of this study was to evaluate the setting time, pH, and calcium ion release of MTAS compared with white Portland cement (CPB-40; Votorantin Cimentos, Camargo Correa SA, Pedro Leopoldo, MG, Brazil), white MTA Angelus (MTA; Angelus, Londrina, PR, Brazil), and AH Plus (Dentsply DeTrey, Konstanz, Germany). Methods: For the evaluation of setting time, each material was analyzed using Gilmore-type needles. Polyethylene tubes with the materials were immersed in distilled water for the measurement of pH (digital pH meter) and calcium release (atomic absorption spectrophotometry). The evaluations were performed at 3, 6, 12, 24, and 48 hours and 7, 14, and 28 days. Data were analyzed by analysis of variance and the Tukey test at 5% significance level. Results: MTAS showed higher calcium release at all experimental periods, a greater increase in pH up to 48 hours and the longest setting time. Conclusions: MTAS presented favorable properties for its indication as a root canal sealer. (J Endod 2011;37:844-846)
Resumo:
Objective. The aim of this study was to evaluate the pH, calcium release, setting time, and solubility of two commercially available mineral trioxide aggregate (MTA) cements (white MTA Angelus and MTA Bio), and of three experimental cements (light-cured MTA, Portland cement with 20% bismuth oxide and 5% calcium sulfate, and an epoxy resin-based cement).Study design. For evaluation of pH and calcium ion release, polyethylene tubes with 1.0 mm internal diameter and 10.0 mm length were filled with the cements and immediately immersed in flasks containing 10 mL deionized water. After 3, 24, 72, and 168 hours, the tubes were removed and the water from the previous container was measured for its pH and calcium content with a pH meter and an atomic absorption spectrophotometer. For analysis of the setting time, Gilmore needles weighing 100 g and 456.5 g were used, in accordance with the American Society for Testing and Materials specification no. C266-03. Solubility of each cement was also tested.Results. All the cements were alkaline and released calcium ions, with a declining trend over time. After 3 hours, Portland cement + bismuth oxide and MTA Bio had the highest pH and light-cured MTA the lowest. After 1 week, MTA Bio had the highest pH and light-cured MTA and epoxy resin-based cement the lowest. Regarding calcium ion release, after 3 hours, Portland cement + bismuth oxide showed the highest release. After 1 week, MTA Bio had the highest. Epoxy resin-based cement and light-cured MTA had the lowest calcium release in all evaluation periods. Regarding setting times, white MTA Angelus and MTA Bio had the shortest, Portland cement + bismuth oxide had an intermediate setting time, and the epoxy resin-based cement had the longest. The materials that showed the lowest solubility values were the epoxy resin-based cement, Portland cement + bismuth oxide, and light-cured MTA. The highest solubility values were presented in white MTA Angelus and MTA Bio.Conclusions. The white MTA Angelus and MTA Bio had the shortest setting times, higher pH and calcium ion release, and the highest solubility. In contrast, the epoxy resin-based cement and light-cured MTA showed lower values of solubility, pH, and calcium ion release. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 250-256)
Resumo:
Introduction: To evaluate calcium ion release and pH of Sealer 26 (S26) (Dentsply, Rio de Janeiro, RJ, Brazil), white mineral trioxide aggregate (MTA), Endo CPM Sealer (CPM1) (EGEO SRL Bajo licencia MTM Argentina SA, Buenos Aires, Argentina), Endo CPM Sealer in a thicker consistency (CPM 2), and zinc oxide and eugenol cement (ZOE). Methods: Material samples (n = 10) were placed in polyethylene tubes and immersed in 10 mL of distilled water. After 3, 6,12,24, and 48 hours and 7,14, and 28 days, the water pH was determined with a pH meter, and calcium release was assessed by atomic absorption spectrophotometry. An empty tube was used as the control group. Results: The control group presented a pH value of 6.9 at all studied periods and did not show the presence of calcium ion. S26 presented greater hydroxyl ion release up to 12 hours (p < 0.05). From 24 hours until 28 days, S26, MTA, CPM1, and CPM2 had similar results. in ail periods, ZOE presented the lowest hydroxyl ion release. CPM1, followed by CPM2, released the most calcium ions until 24 hours (p < 0.05). Between 48 hours and 7 days, CPM1 and CPM2 had the highest release. A greater calcium ion release was observed for CPM2, followed by CPM1 at 14 days and for S26, CPM1, and CPM2 at 28 days. ZOE released the least calcium ions in all periods. Conclusion: Sealer 26, MTA, and Endo CPM sealer at normal or thicker consistency release hydroxyl and calcium ions. Endo CPM sealer may be an alternative as root-end filling material. (J Endod 2009;35:1418-1421)
Resumo:
Substances containing chlorhexidine (CHX) have been studied as intracanal medicaments. The aim of the present study was to characterize the response of mouse subcutaneous connective tissue to CHX-containing medications by conventional optical microscopy. The tissue response was evaluated by implanting polyethylene tubes containing one of the substances evaluated: Calen paste + 0.5% CHX, Calen + 2% CHX, 2% CHX gel, and Calen paste (control). After experimental periods of 7, 21, and 63 days, the implants (n = 10) were removed along with the subcutaneous connective tissue. Tissue samples were subjected to histological processing, and sections were stained with hematoxylin and eosin. Qualitative and quantitative analyses of the number of inflammatory cells, blood vessels, and vascularized areas were performed. Results were analyzed by ANOVA and Tukey tests with the significance level set at 5%. We concluded that Calen + 0.5% CHX led to reparative tissue response in contrast with Calen + 2% CHX and 2% CHX gel, which induced persistent inflammatory response, pointing to the aggressive nature of this mixture. When Calen + 2% CHX and 2% CHX gel were compared, the latter induced more intense inflammatory response. Microsc. Res. Tech., 2012. (C) 2012 Wiley Periodicals, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The surface epithelium of the vas deferens of Agouti paca, a wild and large South American rodent, was basically formed by principal and basal cells being only the principal cells related to endocytosis processes and also secretion taking base on their cytoplasmic ultrastructural features. Principal cell of vas deferens epithelium were characterized mainly by presence of vesicles with several shapes, sizes and internalized content at their apical cytoplasm occurring smaller pits and pale small vesicles seen next to the apical brush border of microvillus. Moreover, coated vesicles, smooth surface vesicles and great vesicles; multivesicular bodies, endosomes and lysosomes were seen. Presence of an apocrine secretory apparatus was also viewed, showing apical cytoplasmic expansions protruding into the vas deferens luminal compartment. The basal flattened cells, without luminal surface contact, occurred next to the basement membrane of the ductus, and did no exhibit special ultrastructural features.
Resumo:
The bark of Styrax camporum Pohl (Styracaceae) differs anatomically in the root and stem. Roots have layered secondary phloem; short sieve tubes with simple, transverse or more or less inclined sieve plates; fibres in tangential bands; astrosclereids; wide rays, and a poorly developed periderm. Stems have non-layered secondary phloem; longer sieve tubes with compound, scalariform, inclined sieve plates; sclerified cells and brachyselereids; a developed periderm, and a non-persistent rhytidome. Prismatic crystals, starch grains, phenolic compounds and lipidic contents were observed in root and stem bark cells. The differences between the secondary phloem of root and stem are discussed.
Resumo:
Objective: To assess alcohol dehydrogenase 3 (ADH3) polymorphism at position Ile349Val as indicator of risk factor for upper aerodigestive tract (UADT) cancer to verify its association with UADT cancer in nonalcoholic or nonsmoking individuals.Design: Cross-sectional study.Setting: Primary care or referral center.Patients: the study group consisted of 141 consecutive patients with newly diagnosed squamous cell carcinoma of the oral cavity, oropharynx, hypopharynx, or larynx admitted for surgical treatment. The comparison group consisted of 94 inpatients without cancer from the A. C. Camargo or other São Paulo (Brazil) hospital and 40 healthy individuals.Intervention: All participants were interviewed and data were collected using a structured questionnaire. After written informed consent was obtained, 20 mL of blood was collected in heparinized tubes.Main Outcome Measures: Odds ratio for ADH3 genotypes using logistic regression models.Results: After adjustment for sex, age, tobacco use, and history of cancer in first-degree family relatives, a significantly higher odds ratio for UADT cancer was observed among individuals with AA genotype and low cumulative alcohol consumption (:5 100 kg of ethanol) (odds ratio=3.8 [95% confidence interval, 1.5-9.7]). A 4-fold increase in odds ratio for UADT cancer among individuals with AA genotype and low tobacco consumption (:525 pack-years) was also found in the adjusted model.Conclusions: These results suggest that genotype AA may be a risk factor for UADT cancer, especially in individuals with low alcohol or tobacco consumption. However, further epidemiological case-control or cohort studies, preferably prospective, are needed to establish the exact role of ADH3 polymorphism and its association with the development of UADT cancers.
Resumo:
The defense reactions against biological (Histoplasma capsulatum and Escherichia coli) and non-biological materials (China ink and nylon thread) were tested in vivo in third instar larvae of Dermatobia hominis. The cellular defense performed by larval hemocytes was observed under electron microscopy. China ink particles were phagocytosed by granular cells 5 h after injection. E. coli cells were internalized by granular cells as early as 5 min after injection and totally cleared 180 min post-injection, when many hemocytes appeared disintegrated and others in process of recovering. H. capsulatum yeasts provoked, 24 h after being injected, the beginning of nodule formation. Nylon thread was encapsulated 24 h after the introduction into the hemocoel. Our results suggest that granular cells were the phagocytic cells and also the responsible for the triggering of nodule and capsule formation. In the presence of yeasts cells and nylon thread, they released their granules that chemotactically attracted the plasmatocytes that on their turn, flattened to surround and isolate the foreign material.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)