280 resultados para Denture retention
Resumo:
Statement of problem. To select the width of denture teeth, the distance between the marks indicating the location of the canines is usually measured around the curvature of the wax occlusal rim; however, most manufacturers' mold charts provide the measurements of the artificial 6 anterior teeth as if they were on a straight line.Purpose. The purpose of this study was to investigate whether the curve distance between the distal surfaces of the maxillary canines can be related to the combined width (straight measurement) of the 6 anterior teeth in 4 ethnic groups.Material and methods. Maxillary stone casts were obtained for 160 dentate subjects of 4 ethnic groups (40 whites, 40 blacks, 40 multiracial - descendants of white and black parents, and 40 Asians). The width of each maxillary anterior tooth was measured on the casts with sliding calipers. The combined width of the 6 anterior teeth (CW) corresponded to the sum of the width of each anterior tooth. The curve distance between the distal surfaces of the canines (CD) was measured by using dental tape and sliding calipers. The Pearson correlation coefficient and regression analysis were used to evaluate the relationship between CD and CW in each ethnic group (alpha=.05).Results. The mean CD and CW values (in mm) obtained were: whites (CD=52.12; CW=45.65); blacks (CD=56.10; CW=48.13); multiracial (CD=53.58; CW=46.54); and Asians (CD=53.29; CW=46.60). Significant (P<.001) correlations between CD and CW measurements were observed for all ethnic groups studied (whites, r=0.957; blacks, r=0.803; multiracial, r=0.917; and Asians, r=0.881). The following linear regression equations were obtained: whites [CD=1.1(CW)+0.3]; blacks [CD=0.95(CW)+9.3]; multiracial [CD=1.2(CW)-1.1]; and Asians [CD=1.0(CW)+5].Conclusions. The curve distance between the distal surfaces of the maxillary canines can be accurately related to the combined width of the 6 anterior teeth in the selection of denture teeth for the studied ethnic groups. (J Prosthet Dent 2012;107:400-404)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: To evaluate the use of the center of the incisive papilla as a guide for the selection of the proper width of maxillary dentures in 4 racial groups. Method and Materials: One hundred sixty stone casts were obtained from impressions of the maxillary arch of white, black, mixed, and Asian subjects. The occlusal surfaces of the casts were photocopied and the images placed on a digitizer. The most anterior and posterior points of the papilla and cusp tips of the canines were digitized. Dentofacial Planner Plus software was used to calculate the distance from a line passing through the cusp tips of the canines to the center of the papilla, defined as the midpoint of the anterior and posterior points of the papilla. The selection error (in millimeters) due to the clinical application of the method of the incisive papilla was calculated and analyzed. Results: In all studied racial groups, there was no coincidence between the center of the incisive papilla and the canine line. The utilization of the center of the papilla would lead to the selection of wider artificial teeth. In 24.9% of the white, 19.3% of the mixed, 32.9% of the black, and 15.5% of the Asian populations, errors greater than 4 mm would be present with the utilization of the papilla. Conclusion: The method of the center of the incisive papilla is not accurate, but may aid in initial artificial teeth selection for the racial groups studied. (Quintessence Int 2008;39:841-845)
Resumo:
Statement of problem. Adverse reactions to the materials used for the fabrication and reline of removable denture bases have been observed.Purpose. The purpose of this study was to systematically review the published literature on the cytotoxicity of denture base and hard reline materials.Material and methods. MEDLINE via PubMed, Google Scholar, and Scopus databases for the period January 1979 to December 2009 were searched with the following key words: (biocompatibility OR cytotoxic* OR allergy OR burning mouth OR cell culture techniques) and (acrylic resins OR denture OR monomer OR relin* OR denture liners). The inclusion criteria included in vitro studies using either animal or human cells, in which the cytotoxicity of the denture base and hard chairside reline resins was tested. Studies of resilient lining materials and those that evaluated other parameters such as genotoxicity and mutagenicity were excluded. Articles published in the English language and in peer-reviewed journals focusing on the cytotoxicity of these materials were reviewed.Results. A total of 1443 articles were identified through the search. From these, 20 studies were judged to meet the selection criteria and were included in the review. In the majority of the studies, continuous cell lines were exposed to eluates of specimens made from the materials, and mitochondrial activity was used to estimate cell viability. The tested acrylic resins were grouped according to 5 major categories: (1) heat-polymerized; (2) microwave-polymerized; (3) autopolymerizing; (4) light-polymerized; and (5) hard chairside reliners.Conclusions. This review provided some evidence that the heat-polymerized resins showed lower cytotoxic effects than autopolymerizing denture base acrylic resins and light or dual polymerized reline resins. However, because of the large number of variables in the reviewed literature, a definitive conclusion could not be drawn. (J Prosthet Dent 2012;107:114-127)
Resumo:
Background: This study evaluated the effect of disinfection by immersion and microwave irradiation on the roughness of one denture base resin (Lucitone-L) and five relining materials, three hard (Tokuyama Rebase II-TR, New Truliner-NT, Ufigel Hard-UH) and two resilient (Trusoft-T, Sofreliner-S).Methods: Fifty specimens were made and divided into groups: CL2 specimens were brushed with 4% chlorhexidine (1 min), immersed in the same solution (10 min) and immersed in water (3 min); MW2 specimens were immersed in water and microwave irradiated (650W; 6 min); CL2 and MW2 specimens were disinfected twice; CL7 and MW7 specimens were submitted to seven cycles using chlorhexidine or microwave irradiation, respectively; W specimens were not disinfected and remained in water (37 degrees C; 7 days).Results: Results were statistically analysed (p = 0.05) and revealed that, at baseline, the highest mean value was observed for T (p < 0.001). Material NT showed increase in roughness after the first (p = 0.003), second (p = 0.001), seventh (p = 0.000) cycles of microwave disinfection and after 7 days of immersion in water (p = 0.033).Conclusions: Resilient liner S presented significant increase in roughness after the second cycle of disinfection with chlorhexidine (p = 0.003). Material T exhibited significantly decreased roughness in group W (p = 0.010), while microwaving produced severe alterations on its surface.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to determine the effect of two different preventive oral hygiene education and motivation programmes on the plaque and gingival index, as well as denture hygiene of patients provided with removable partial denture (RPD) during a 12-month follow-up.A total of 53 partially edentulous patients were recruited for this study. The presence or absence of plaque and gingival bleeding by gentle probing was scored on all tooth surfaces at the preliminary visit. The plaque and gingival indexes were measured using the Loe index. Following treatment, the patients were randomly divided into three groups. In Control Group I, subjects were instructed to continue their personal oral hygiene routine. In Group II, participants were given verbal instructions and a self-educational manual on oral hygiene without illustrations. In Group III, oral hygiene guidance was delivered using a combination of verbal instructions and a self-teaching manual. To evaluate the effect of the different modes of instruction, the presence or absence of plaque and gingival bleeding was scored on all tooth surfaces (day zero examination) and re-examined 7, 15 and 30 days, 3, 6 and 12 months following RPD placement. The state of denture hygiene was evaluated 7, 15 and 30 days and 3, 6 and 12 months following rehabilitation. Parametric statistics was applied to dental plaque and gingival indexes. For accumulation of plaque and calculus on the RPD, non-parametric statistic was applied.The frequency of plaque found during the preliminary visit was higher than that found in the other periods. With regard to gingival index, significant difference was found between the preliminary visit examination and other periods. There was a significant difference in the plaque accumulation on the denture surface between groups I and III.The different methods of oral hygiene instruction used in this study indicate that the type of education was not of significant importance.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: The purpose of this study was to evaluate the flexural strength of repairs made with autopolymerising acrylic resin after different treatments of joint surfaces.Material and Methods: Fifty rectangular specimens were made with heat-polymerised acrylic resin and 40 were repaired with autopolymerising acrylic resin following joint surface treatments: group 1 (intact specimens), group 2 (chemical treatment: wetting with methyl-methacrylate for 180 s), group 3 (abraded with silicon carbide paper), group 4 (abraded and wetting with methyl-methacrylate for 180 s) and group 5 (without surface treatment). The flexural strength was measured by a three-point bending test using a universal testing machine with a 100 Kgf load cell in the centre of repair at 5 mm/min cross-head speed. All data were analysed using one-way ANOVA and Tukey HSD test for multiple comparisons (p < 0.05).Results: Among repaired specimens, groups 2 and 4 had 66.53 +/- 3.4 and 69.38 +/- 1.8 MPa mean values and were similar. These groups had superior flexural strength than groups 3 and 5 that were similar and had 54.11 +/- 3.4 and 51.24 +/- 2.8 MPa mean values, respectively. Group 1 had a mean value of 108.30 +/- 2.8 MPa being the highest result.Conclusion: It can be concluded that the treatment of the joint surfaces with methyl-methacrylate increases the flexural strength of denture base repairs, although the strength is still lower than that observed for the intact denture base resin. Abrasion with sandpaper was not able to influence the flexural strength of repaired denture bases.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study evaluated the influence of microwave disinfection on the strength of intact and relined denture bases. Water sorption and solubility were also evaluated. A heat-polymerized acrylic resin (Lucitone 550) was used to construct 4-mm-thick (n = 40) and 2-mm-thick (n = 160) denture bases. Denture bases (2mm) were relined with an autopolymerizing resin (Tokuso Rebase Fast, Ufi Gel Hard, Kooliner, or New Truliner). Specimens were divided into four groups (n = 10): without treatment, one or seven cycles of microwave disinfection (650 W for 6 min), and water storage at 37 degrees C for 7 days. Specimens were vertically loaded (5 mm/min) until failure. Disc-shaped specimens (50 min x 0.5 mm) were fabricated (n = 10) to evaluate water sorption and solubility. Data on maximum fracture load (N), deflection (%), and solubility (%) were analyzed by two-way analysis of variance and Student-Newman-Keuls tests (alpha = 0.05). One cycle of microwave disinfection decreased the deflection at fracture and fracture energy of Tokuso Rebase Fast and New Truliner specimens. The strength of denture bases microwaved daily for 7 days was similar to the strength of those immersed in water for 7 days. Microwave disinfection increased the water sorption of all materials and affected the solubility of the reline materials. (C) 2007 Wiley Periodicals, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Retention of particulate organic matter was investigated over a range of water discharges in pool and riffle zones of a tropical stream (Itauna Stream, São Paulo, Brazil). A closed-system leaf release and capture method was used to quantify leaf retention in a 50-m reach of the stream. Instantaneous retention rates (k) were calculated by a negative exponentialmodel and specific retention rates (ke) computed for each 1m interval. The mean k was 0.0161 +/- 0.0101 (S.E.) and ranged from 0.005 to 0.036 during the study period. This suggests a low retention of particulate matter. The evidence provided by this study shows that there was a relationship between retention and discharge. At low discharges, greater percentages of leaves were retained in a 3-h period while high discharges resulted in low retention percentages within the studied reach. In the Itauna Stream, no significant difference (p < 0.05) was found between the ke values of pool and riffle zones.