407 resultados para Cimento endodontico
Resumo:
To compare the abrasion wear resistance and superficial roughness of different glass ionomer cements used as restorative materials, focusing on a new nanoparticulate material. Material and Method: Three glass ionomer cements were evaluated: Ketac Molar, Ketac N100 and Vitremer (3M ESPE, St. Paul, MN, USA), as well as the Filtek Z350 (3M ESPE, St. Paul, MN, USA). For each material were fabricated circular specimens (n=12), respecting the handling mode specified by the manufacturer, which were polished with sandpaper disks of decreasing grit. The wear was determined by the amount of mass (M) lost after brushing (10,000 cycles) and the roughness (Ra) using a surface roughness tester. The difference between the Minitial and Mfinal (ΔM) as well as beroughness of aesthetic restorative materials: an in vitro comparison. SADJ. 2001; 56(7): 316-20. 11. Yip HK, Peng D, Smales RJ. Effects of APF gel on the physical structure of compomers and glass ionomer cements. Oper. Dent. 2001; 26(3): 231-8. 12. Ma T, Johnson GH, Gordon GE. Effects of chemical disinfectants on the surface characteristics and color of denture resins. J Prosthet Dent 1997; 77(2): 197-204. 13. International organization for standardization. Technical specification 14569-1. Dental Materials – guidance on testing of wear resistance – PART I: wear by tooth brushing. Switzerland: ISO; 1999. 14. Bollen CML, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater.1997; 13(4): 258-9. 15. Kielbassa AM, Gillmann C, Zantner H, Meyer-Lueckel H, Hellwig E, Schulte-Mönting J. Profilometric and microradiographic studies on the effects of toothpaste and acidic gel abrasivity on sound and demineralized bovine dental enamel. Caries Res. 2005; 39(5): 380-6. 16. Tanoue N, Matsumara H, Atsuta M. Wear and surface roughness of current prosthetic composites after toothbrush/dentifrice abrasion. J Prosthet Dent. 2000; 84(1): 93-7. 17. Heath JR, Wilson HJ. Abrasion of restorative materials by toothpaste. J Oral Rehabil. 1976; 3(2): 121-38. 18. Frazier KB, Rueggeberg FA, Mettenburg DJ. Comparasion of wearresistance of class V restorative materials. J Esthet Dent. 1998; 10(6): 309-14. 19. Momoi Y, Hirosakil K, Kohmol A, McCabe JF. In vitro toothebrushdentifrrice abrasion of resin-modified glass ionomers. Dent Mater. 1997; 13(2): 82-8. 20. Turssi CP, Magalhães CS, Serra MC, Rodrigues Jr.AL. Surface roughness assessment of resin-based materials during brushing preceded by pHcycling simulations. Oper Dent. 2001; 26(6): 576-84. 21. Wang L, Cefaly DF, Dos Santos JL, Dos Santos JR, Lauris JR, Mondelli RF, et al. In vitro interactions between lactic acid solution and art glassionomer cements. J Appl Oral Sci. 2009; 17(4): 274-9. 22. Carvalho FG, Fucio SB, Paula AB, Correr GM, Sinhoreti MA, PuppinRontani RM. Child toothbrush abrasion effect on ionomeric materials. J Dent Child (Chic). 2008; 75(2): 112-6. 23. Coutinho E, Cardoso MV, De Munck J, Neves AA, Van Landuyt KL, Poitevin A, et al. Bonding effectiveness and interfacial characterization of a nano-filled resin-modified glass-ionomer. Dent Mater. 2009; 25(11): 1347-57. tween Rainitial and Rafinal (ΔRa) were also used for statistical analysis (α=0.05). Results: Except for the composite, significant loss of mass was observed for all glass ionomer cements and the ΔM was comparable for all of them. Significant increase in roughness was observed only for Vitremer and Ketac N100. At the end of the brushing cycle, just Vitremer presented surface roughness greater than the composite resin. Conclusion: All glass ionomer cements showed significant weight loss after 10,000 cycles of brushing. However, only Vitremer showed an increase of roughness greater than the Z350 resin, while the nanoparticulate cement Ketac N100 showed a smooth surface comparable to the composite.
Resumo:
Objective: The objective of this paper was to verify if the final irrigation at 17% EDTA, separately or followed by chlorhexidine digluconate at 2% interferes on the apical marginal leakage in root canal overfilling, due to the use of two root canal filling materials (Sealer 26TM or SealapexTM). Methods: Forty lower incisors extracted, with a single root canal, were biomechanically prepared, at 2.0mm beyond the radicular apex, with ProTaper SystemTM, finishing it with the F3 instrument. Irrigation was accomplished with 1.0 mL NaOCl at 2.5% at each change of equipment caliper and, in the end, with 5.0 mL normal saline solution. After achieving this procedure, the foraminal channels was standardized with a file K 25 until its DO appears in the foraminal opening. From this moment, the teeth were subdivided into two groups of 20 specimens each, because of the final irrigation method used: I – irrigation with EDTA at 17% for 3min and II – identical protocol, thus, after EDTA aspiration at17%, it was again irrigated with chlorhexidine digluconate at 2%, also kept intra-canal for 3min. Each group was again sub-divided into two sub-groups (ten teeth each), according to the cement used (Sealer 26TM or SealapexTM), and filled by using a single gutta-percha F1 (ProTaperTM, Universal Filling), in such a manner that it goes 2.0 mm beyond the radicular apex. Soon after that, the teeth were immersed in Rhodamine BTM for 72h, vacuum and after the roots have been bucolingually grooved, the leakages marked were measured with program Image ToolTM. Results and Conclusions: The leakage magnitude was similar among themselves (p > 0.05), except for group Sealapex®, thus the final use with chlorhexidine reduced apical leakage (p < 0.05).
Resumo:
The Portland cement has shown similar biological properties to calcium hydroxide, but its radiopacity is lower. Therefore, the addition of materials that minimize this deficiency should be considered. OBJECTIVE: To evaluate the apical sealing ability and pH of a white Portland cement added of several radiopacifying agents. MATERIAL AND METHODS: Forty bovine roots with incomplete apices were selected, and the foraminal openings were standardized to PM 720G bur. After the external root sealing, an apical intracanal barrier 10.0 mm thick was executed with the white Portland cement powder, pure or added of a radiopacifying agent (iodoform, zinc oxide or bismuth subnitrate), and distilled water (0.37 mL). The apical roots were immersed 24h in water in humid atmosphere, and after that they were immersed 24h in 2% Rhodamine B, under vacuum. In sequence, the roots were longitudinally sectioned, the root fragments were photographed, the images were digitalized and the apical infiltration was measured by the Image Tool program. The pH solutions were also evaluated, in 24h and 48h and 7 and 30 days. Data were submitted to Anova test. RESULTS: The zinc oxide solution has the lowest apical infiltration in relation to the other groups (p < 0.05). The pH behavior varied during the analysis, and in the period of 24h all groups showed the highest values (p < 0.05). CONCLUSION: The type of radiopacifying agent used interferes in the sealing ability of the apical barrier, and zinc oxide showed to be the most beneficial one. The pH varies according to the period of analysis, and the highest values were obtained in the first 24h (p < 0.05).
Análise físico-química do MTA e do cimento Portland associado a quatro diferentes radiopacificadores
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
The evolution of techniques and materials applied to adhesive ceramic restorations resulted in the intensification of its use, proving to be an excellent method of aesthetic restoration. Some important features of this technique are its conservative preparation, which avoids an excessive loss of tooth structure and its high aesthetic value provided by the ceramic even when utilized under different color of dental substrates. The aim of this paper was to report a clinical case with full crowns, porcelain veneers and non-prep veneers, enhancing peculiarities related to the material used, tooth preparation techniques, cementing, indications and contraindications.
Resumo:
Objetivo: o objetivo desse estudo foi investigar os efeitos da nova formulação do Cimento Portland (CPM) comparando-o ao MTA Angelus na viabilidade celular e liberação de IL-1b e IL-6 em fibroblastos de rato. Métodos: tubos de polietileno preenchidos com os materiais estudados foram colocados em placas de cultura celular de 24 poços com fibroblastos de rato. Tubos vazios foram utilizados como controle. Após 24 horas, ensaio MTT foi utilizado para avaliar a viabilidade celular. Para o ensaio de citocinas, fibroblastos de ratos foram incubados em placas de fundo plano de 24 poços com discos dos materiais no fundo, ou sem material, como controle. Após 24 horas, o meio de cultura foi coletado para a avaliação das citocinas pelo ELISA. Resultados: o CPM e MTA Angelus não inibiram a viabilidade celular. Ambos os materiais induziram liberação de IL-6 e IL-1b e a quantidade foi estatisticamente significativa se comparada ao grupo controle. Conclusão: ambos os materiais não foram citotóxicos em cultura de fibroblastos e induziram a liberação de IL-6 e IL-1b.
Resumo:
Introdução: o objetivo do estudo foi avaliar a resposta do tecido subcutâneo de ratos a implantes de tubos de polietileno com cimento Portland modificado (CPM) (EGEO S.R.L., Buenos Aires, Argentina) comparado com o MTA Angelus® (Angelus, Londrina/PR). Métodos: esses materiais foram colocados em tubos de polietileno e implantados no tecido conjuntivo dorsal de ratos Wistar por 7, 15, 30, 60 e 90 dias. Os espécimes foram preparados e corados com hematoxilina e eosina ou Von Kossa, ou não corados por luz polarizada. Foram realizadas avaliações quantitativas e qualitativas das reações. Resultados: ambos os materiais causaram reações moderadas em 7 dias, decaindo com o tempo. O MTA Angelus causou reações leves em 15 dias, decaindo com o tempo. A resposta foi similar ao controle em 30, 60 e 90 dias com CPM e MTA Angelus. Foram observadas mineralização e granulações birrefringentes à luz polarizada em ambos os materiais. Conclusões: foi possível concluir que o CPM e o MTA Angelus foram biocompatíveis em modelo de rato e estimularam a mineralização.
Resumo:
Pós-graduação em Ciência Odontólogica - FOA
Resumo:
Introdução: Os processos industriais geram grandes quantidades de resíduos, representando um grande desperdício de matéria prima e causando impactos negativos ao meio ambiente. No caso dos resíduos gerados pelas fábricas de pás eólicas para aerogeradores de Sorocaba-S.P., eles podem ser reaproveitados na incorporação em cimento Portland. O interesse é utilizá-los na construção civil como blocos sem fins estruturais para construção de muros, guias, calçadas, pisos, etc. Os corpos confeccionados devem obedecer às normas técnicas brasileiras e as suas propriedades relativas à resistência, compressão, absorção de água e distribuição espacial dos resíduos nestes corpos devem ser avaliadas. Objetivos: Devido à importância de se conhecer as propriedades dos corpos produzidos com a incorporação de resíduos de pás eólicas, este trabalho faz uma avaliação através de imagens de raios X de sua distribuição espacial para verificar a viabilidade do emprego desta técnica no estudo da incorporação de resíduos para, futuramente, em conjunto com outras pesquisas que estão sendo realizadas, verificar a relação desta distribuição com as propriedades mecânicas dos corpos produzidos. Métodos: Objetivando a incorporação desse resíduo como substituto parcial dos agregados miúdos em argamassa, foram fabricados corpos de prova (CPs) seguindo as normas da ABNT-NBR 5738. Todos os corpos foram desmoldados após 24 horas de sua confecção e imersos em água por 28 dias para a cura. Utilizou-se o traço 3:1, areia e cimento, em relação a massa dos componentes, ou seja, para cada 300 g de areia adicionou-se 100 g de cimento. Na confecção de argamassa com resíduo utilizou-se o mesmo traço, porém com a substituição de parte da areia pelo resíduo. Foram fabricados CPs com 5%, 15%, 50% e 0% de resíduo para que este sirva de referência. Como os corpos possuem um formato cilíndrico, foram obtidas imagens em duas projeções: frontal e superior utilizando um equipamento digital com os seguintes parâmetros: 83 kVp e 16 mAs e, 85 kVp e 30 mAs, respectivamente. Resultados: As imagens mostram que na projeção frontal é possível verificar que a distribuição do resíduo nos corpos é homogênea, o que pode proporcionar uniformidade nos resultados de testes de resistência à compressão que serão realizados futuramente. Porém, na projeção superior ainda será necessário um estudo dos parâmetros que deverão ser utilizados no equipamento de raios X para melhorar a sua qualidade. Além disso, métodos de processamento digital de imagens poderão ser aplicados nas imagens para auxiliar na visualização dos resíduos incorporados. Também pode ser visto nas imagens que a forma utilizada para a incorporação do resíduo resulta na sua distribuição uniforme, compatível com o que se deseja neste tipo de incorporação.