137 resultados para Application methods
Resumo:
The aim of the present study is to assess the behaviour of different motivation methods on levels of oral hygiene among schoolchildren aged from 7 to 9 years in Araraquara, SP, Brazil. The methods tested were: indirect instruction using 'The Smiling Robot' (group I), indirect instruction through class presentation (group II) and direct instruction with macromodels (group III). A control group was also constituted, which received no kind of motivation (group IV). The O'Leary Plaque Index was used as the evaluation method, applied before the instruction and 30 days after application of the different methods. It was noted that the plaque index had not decreased in group IV only. In conclusion, all the motivation methods promoted significant decrease of plaque index and among these methods, the 'The Smiling Robot' was the one that provided the best results.
Resumo:
Titanium and its alloys provide high strength-to-weight ratios, good fatigue strength and increased corrosion resistance compared with others materials. Its acceptance in aerospace has been limited by costs considerations such as high cost of raw material, high buy-to-fly ratios and expensive machining operations. Significant cost reductions can be obtained by vacuum sintering and powder metallurgy (P/M) techniques by producing near net shapes and consequently minimizing material waste and machining time. The Ti 35Nb alloy exhibit a low modulus of elasticity. Stemming from the unique combination of high strength, low modulus of elasticity and low density, this alloy is intrinsically more resistant to shock and explosion damages than most other engineering materials. Samples were produced by mixing of initial metallic powders followed by uniaxial and cold isostatic pressing with subsequent densification by sintering between 900 and 1600 °C, in vacuum. Sintering behavior was studied by means of dilatometry. Sintered samples were characterized for phase composition, microstructure and microhardness by X-ray diffraction, scanning electron microscopy and Vickers indentation, respectively. Density was measured by Archimedes method. Copyright © 2004 Society of Automotive Engineers, Inc.
Resumo:
Methods were developed for the analysis of acetonitrile and its metabolite cyanide in the blood of rats exposed to acetonitrile. Acetonitrile was analyzed by the headspace technique coupled to gas chromatography with detection by flame ionization, and cyanide was analyzed by high-performance liquid chromatography with fluorescence detection (λ ex = 418 nm and λ em = 460 nm) after derivatization of the ion with naphthalene 2,3-dicarboxyaldehyde and taurine. The quantitation limits of the methods for the analysis of acetonitrile and cyanide were 4.875 μg/mL and 0.025 μg/mL, respectively. The coefficients of variation of 10% or less obtained for intra- and interassay precision indicate the precision of these analytical methods and the systematic errors, all less than 5%, indicate that the methods are quite accurate. The methods were applied to an experimental study after the animals received acetonitrile at the doses of 2 mmol/kg or 5 mmol/kg.
Resumo:
Most of architectures proposed for developing Distributed Virtual Environment (DVE) allow limited number of users. To support the development of applications using the internet infrastructure, with hundred or, perhaps, thousands users logged simultaneously on DVE, several techniques for managing resources, such as bandwidth and capability of processing, must be implemented. The strategy presented in this paper combines methods to attain the scalability required, In special the multicast protocol at application level.
Resumo:
Context and objective: Records of contact with mercury (Hg) exist for more than 3500 years and several problems related to the use of this element can be noticed. Considering inexistence of current reports about it, quality of life perception evaluation was studied in people chronically intoxicated by mercury in an industrial environment. Design and setting: This is a cross-sectional descriptive observational study. Information from 47 urban-industrial workers from lamps manufacturing in São Paulo, clinically diagnosed as intoxicated by mercury and currently followed by the Occupational Health Service of Faculdade de Medicine da Universidade de São Paulo, with average age of 41.7 years old, was considered. Methods: SF36 questionnaire application was performed, with inferences tested by χ-square proof, by Spearman linear correlation and Mann-Whitney non-parametric test, adopting p < 0.05 as significant level. Results: In the eight domains, observed medians are 40% for physical functioning; 0 for physical function; 30% for body pain; 30% for general health; 22.2% for vitality; 50% for social functioning; 0 for emotional role and 36% for mental health. Correlation between age and SF36 domains does not reveal statistical significance, except for physical functioning, indicating that lower scores presented by older people in this domain are not followed by changes on other ones. Conclusions: Values obtained in people chronically intoxicated by mercury are actually lower, in the motor and mental scope components. Some instruments domains are higher for men than for women. Older ages are inversely associated to good performance in physical function domain. © Copyright Moreira Jr. Editora. Todos os direitos reservados.
Resumo:
The main objective involved with this paper consists of presenting the results obtained from the application of artificial neural networks and statistical tools in the automatic identification and classification process of faults in electric power distribution systems. The developed techniques to treat the proposed problem have used, in an integrated way, several approaches that can contribute to the successful detection process of faults, aiming that it is carried out in a reliable and safe way. The compilations of the results obtained from practical experiments accomplished in a pilot distribution feeder have demonstrated that the developed techniques provide accurate results, identifying and classifying efficiently the several occurrences of faults observed in the feeder. © 2006 IEEE.
Resumo:
The objective of this paper is to show an alternative representation in time domain of a non-transposed three-phase transmission line decomposed in its exact modes by using two transformation matrices. The first matrix is Clarke's matrix that is real, frequency independent, easily represented in computational transient programs (EMTP) and separates the line into Quasi-modes α, β and zero. After that, Quasi-modes α and zero are decomposed into their exact modes by using a modal transformation matrix whose elements can be synthesized in time domain through standard curve-fitting techniques. The main advantage of this alternative representation is to reduce the processing time because a frequency dependent modal transformation matrix of a three-phase line has nine elements to be represented in time domain while a modal transformation matrix of a two-phase line has only four elements. This paper shows modal decomposition process and eigenvectors of a non-transposed three-phase line with a vertical symmetry plane whose nominal voltage is 440 kV and line length is 500 km. © 2006 IEEE.
Resumo:
This study aimed to evaluate the durability of adhesion between acrylic teeth and denture base acrylic resin. The base surfaces of 24 acrylic teeth were flatted and submitted to 4 surface treatment methods: SM1 (control): No SM; SM2: application of a methyl methacrylate-based bonding agent (Vitacol); SM3: air abrasion with 30-μm silicone oxide plus silane; SM4: SM3 plus SM2. A heat-polymerized acrylic resin was applied to the teeth. Thereafter, bar specimens were produced for the microtensile test at dry and thermocyled conditions (60 days water storage followed by 12,000 cycles). The results showed that bond strength was significantly affected by the SM (P < .0001) (SM4 = SM2 > SM3 > SM1) and storage regimens (P < .0001) (dry > thermocycled). The methyl methacrylate-based adhesive showed the highest bond strength.
Resumo:
• Aim: To observe the effects of topical application of 5-fluorouracil (5-FU) on the rabbits corneal limbus. • Methods: 5-FU was applied topically to the corneoscleral region of rabbits eyes. The animals were sacrificed immediately or 7, 15, 30 and 60 days later, and tissues were submitted to histological examination. • Results: All animals presented corneoscleral deepithelization close to the site of application during the immediate post-operative period, whereas on the 4th postoperative day ulceration was no longer present. Histological examination showed absence of epithelium and slight edema. After one week (G2), 2 animals presented epithelial defects, thickened epithelium with larger basal cells and loose chromatin, and slight subepithelial edema. The remaining groups showed no alterations. • Conclusion: The 5-FU topically on the corneoscleral limbus postpone the epitelization.
Resumo:
Purpose: The aim of this work was to evaluate the bone-repair process after implantation of homogenous demineralized dentin matrix (HDDM) slices in surgical defects created in the parietal bones of rabbits with alloxan-induced diabetes. Materials and Methods: Forty-eight rabbits were selected and divided into 4 groups of 12 rabbits: the control group, diabetic rabbits (D), diabetic rabbits with a PTFE barrier (D-PTFE), and diabetic rabbits with a PTFE barrier and with slices of homogenous demineralized dentin matrix (D-PTFE+HDDM). The diabetic animals received a single dose of alloxan monohydrate (90 mg/kg) intravenously on the marginal ear vein, and their blood glucose was verified daily. The rabbits were sacrificed after 15, 30, 60, and 90 days. The histologic findings show both better bone structure and significantly greater bone density, as determined by histomorphometric analysis, for the D-PTFE + HDDM group than for the other 3 groups (P < .01). It was also observed that the mean bone density increased gradually from 15 to 90 days (except in the D-PTFE group). Conclusion: It was concluded that the HDDM was biocompatible with the bone repair of diabetic rabbits and that HDDM slices stimulated bone tissue formation. Facilitation of bone repair with HDDM could be useful in diabetic patients.
Resumo:
The objective of this article is to apply the Design of experiments technique along with the Discrete Events Simulation technique in an automotive process. The benefits of the design of experiments in simulation include the possibility to improve the performance in the simulation process, avoiding trial and error to seek solutions. The methodology of the conjoint use of Design of Experiments and Computer Simulation is presented to assess the effects of the variables and its interactions involved in the process. In this paper, the efficacy of the use of process mapping and design of experiments on the phases of conception and analysis are confirmed. © 2007 IEEE.
Resumo:
Aim: Based on the hypothesis the application of a low-viscosity hydrophobic resin coating improves the bond of all-in-one adhesive, the purpose of the study was to evaluate the bond strength of four adhesive systems to bovine root dentin using the push-out test method. Methods and Materials: The root canals of 32 bovine roots (16 mm) were prepared to a length of 12 mm using a FRC Postec Plus preparation drill. The specimens were allocated into four groups according to the adhesive system used: (Group 1) All-in-one Xeno III; (Group 2) All-in-one Xeno III+ScotchBond Multi-Purpose Plus Adhesive; (Group 3) Simplified Etch & Rinse One Step Plus; and (Group 4) Multi-Bottle Etch & Rinse All-Bond 2. A fiber-reinforced composite retention post was reproduced using an additional silicon impression and fabricated with DuoLink resin cement. The root specimens were treated with the selected adhesive systems, and the resin posts were luted in the canals with DuoLink resin cement. Each root specimen was cross sectioned into four samples (±1.8 mm in thickness), and the post sections were pushed-out to determine the bond strength to dentin. Results: Group 2 (2.9±1.2) was statistically higher than Group 1 (1.1±0.5) and Group 3 (1.1±0.5). Groups 1 and 3 showed no statistically significant difference while Group 4 (2.0±0.7) presented similar values (p>0.05) to Groups 1, 2, and 3 [(one-way analysis of variance (ANOVA)] and Tukey test, α=0.05). Conclusion: The hypothesis was accepted since the application of the additional layer of a low-viscosity bonding resin improved the bond of the all-in-one adhesive. Further studies must be conducted to evaluate the long-term bond.
Resumo:
Background: The ability of biofilm formation seems to play an essential role in the virulence of coagulase-negative staphylococci (CNS). The most clearly characterized component of staphylococcal biofilms is the polysaccharide intercellular adhesin (PIA) encoded by the icaADBC operon. Biofilm production was studied in 80 coagulase-negative staphylococci (CNS) strains isolated from clinical specimens of newborns with infection hospitalized at the Neonatal Unit of the University Hospital, Faculty of Medicine of Botucatu, and in 20 isolates obtained from the nares of healthy individuals without signs of infection. The objective was to compare three phenotypic methods with the detection of the icaA, icaD and icaC genes by PCR. Findings: Among the 100 CNS isolates studied, 82% tested positive by PCR, 82% by the tube test, 81% by the TCP assay, and 73% by the CRA method. Using PCR as a reference, the tube test showed the best correlation with detection of the ica genes, presenting high sensitivity and specificity. Conclusions: The tube adherence test can be indicated for the routine detection of biofilm production in CNS because of its easy application and low cost and because it guarantees reliable results with excellent sensitivity and specificity. © 2010 Cunha et al; licensee BioMed Central Ltd.
Resumo:
In this project, the main focus is to apply image processing techniques in computer vision through an omnidirectional vision system to agricultural mobile robots (AMR) used for trajectory navigation problems, as well as localization matters. To carry through this task, computational methods based on the JSEG algorithm were used to provide the classification and the characterization of such problems, together with Artificial Neural Networks (ANN) for pattern recognition. Therefore, it was possible to run simulations and carry out analyses of the performance of JSEG image segmentation technique through Matlab/Octave platforms, along with the application of customized Back-propagation algorithm and statistical methods as structured heuristics methods in a Simulink environment. Having the aforementioned procedures been done, it was practicable to classify and also characterize the HSV space color segments, not to mention allow the recognition of patterns in which reasonably accurate results were obtained. ©2010 IEEE.
Resumo:
Aim: Nowadays, research on orthopedic and dental implants is focused on titanium alloys for their mechanical properties and corrosion resistance in the human body environment. Another important aspect to be investigated is their surface topography, which is very important to osseointegration. With laser beam irradiation for roughening the implants surface an easier control of the microtopography is achieved, and surface contamination is avoided. The aim of this study was to assess human bone marrow stem cells response to a newly developed titanium alloy, Ti-15Mo, with surface topography modified by laser beam irradiation. Materials and methods: A total of 10 Ti machined disks (control), 10 Ti-15Mo machined disks and 10 Ti-15Mo disks treated by laser beam-irradiation were prepared. To study how Ti-15Mo surface topografy can induce osteoblast differentiation in mesenchymal stem cells, the expression levels of bone related genes and mesenchymal stem cells marker were analyzed, using real time Reverse Transcription-Polymerase Chain Reaction. Results: In Test 1 (comparison between Ti-15Mo machined disks and Ti-machined disks) quantitative real-time RT-PCR showed a significant induction of ALPL, FOSL1 and SPP1, which increase 20% or more. In Test 2 (comparison between Ti-15Mo laser treated disks and Ti-machined disks) all investigated genes were up-regulated. By comparing Test 1 and Test 2 it was detected that COL1A1, COL3A1, FOSL1 and ENG sensibly increased their expression whereas RUNX2, ALPL and SPP1 expression remained substantially unchanged. Conclusion: The present study demonstrated that laser treated Ti-15Mo alloys are promising materials for implants application.