143 resultados para Air transformer substations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The São Paulo State has 36 million people, 25 million living in three metropolitan areas. Only the São Paulo Metropolitan Region (SPMR) includes the state capital (São Paulo City) plus 38 cities, where ≈ 18 million people live, affected by frequent episodes of ozone, NOx, and fine particulate matter. In 2003, it was estimated that 15.1% of the SPMR vehicles used ethanol and 70.2% used the local gasoline. Natural gas vehicles have witnessed a booming participation in the last years, mainly through conversion of gasoline cars, and the present fleet is almost one million vehicles. To face the problems generated by light vehicles emissions the Federal Government set a program called PROCONVE - Program of Air Pollution Control from Vehicles - in 1986 and since then until now a significant reduction was reached, but the growth of the fleet hides most of the emission cuts. A discussion covers the evolution of the air pollution management in São Paulo; and innovative tools for air pollution management - both for mobile and stationary sources. This is an abstract of a paper presented at the 98th AWMA Annual Conference and Exhibition (Minneapolis, MN 6/21-24/2005).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rubber pest mites, Calacarus heveae and Tenuipalpus heveae, reach economic damage levels at the end of the rainy season and the beginning of the dry season in Brazil. Therefore, low humidity adaptation might be an important characteristic for predatory mites to successfully control pest organisms. This study determined the effect of the relative humidity (RH) levels of 30-100% on the hatching of larvae of Amblyseius acalyphus, Euseius citrifolius, Iphiseiodes zuluagai, Metaseiulus camelliae, Agistemus floridanus and Zetzellia malvinae at 25 ± 0.5°C. These predatory mites are common on rubber trees in the state of São Paulo and might be used for introduction in the major rubber tree production regions in the state of Mato Grosso. At 70% RH or higher, viability was 70% or higher for all species, indicating that their performance might be higher during the rainy season than during the dry season. Eggs of E. citrifolius and M. camelliae presented higher viability at the lower relative humidity levels than those of other species, indicating that these species might have higher chance to persist in the dry season. It is suggested that M. camelliae should be further evaluated for introduction in the state of Mato Grosso, considering that this mite is not yet present in that area. © Springer 2006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to study the local impact on the upper troposphere/lower stratosphere air composition of an extreme deep convective system. For this purpose, we performed a simulation of a convective cluster composed of many individual deep convective cells that occurred near Bauru (Brazil). The simulation is performed using the 3-D mesoscale model RAMS coupled on-line with a chemistry model. The comparisons with meteorological measurements show that the model produces meteorological fields generally consistent with the observations. The present paper (part I) is devoted to the analysis of the ozone precursors (CO, NO x and non-methane volatile organic compounds) and HO x in the UTLS. The simulation results show that the distribution of CO with altitude is closely related to the upward convective motions and consecutive outflow at the top of the convective cells leading to a bulge of CO between 7 km altitude and the tropopause (around 17km altitude). The model results for CO are consistent with satellite-borne measurements at 700 hPa. The simulation also indicates enhanced amounts of NO x up to 2 ppbv in the 7-17 km altitude layer mainly produced by the lightning associated with the intense convective activity. For insoluble non-methane volatile organic compounds, the convective activity tends to significantly increase their amount in the 7-17km layer by dynamical effects. During daytime in the presence of lightning NO x, this bulge is largely reduced in the upper part of the layer for reactive species (e.g. isoprene, ethene) because of their reactions with OH that is increased on average during daytime. Lightning NO x also impacts on the oxydizing capacity of the upper troposphere by reducing on average HO x, HO 2, H 2O 2 and organic hydroperoxides. During the simulation time, the impact of convection on the air composition of the lower stratosphere is negligible for all ozone precursors although several of the simulated convective cells nearly reach the tropopause. There is no significant transport from the upper troposphere to the lower stratosphere, the isentropic barrier not being crossed by convection. The impact of the increase of ozone precursors and HO x in the upper troposphere on the ozone budget in the LS is discussed in part II of this series of papers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review focuses on the heterogeneous photocatalytic treatment of organic dyes in air and water. Representative studies spanning approximately three decades are included in this review. These studies have mostly used titanium dioxide (TiO2) as the inorganic semiconductor photocatalyst of choice for decolorizing and decomposing the organic dye to mineralized products. Other semiconductors such as ZnO, CdS, WO3, and Fe2O3 have also been used, albeit to a much smaller extent. The topics covered include historical aspects, dark adsorption of the dye on the semiconductor surface and its role in the subsequent photoreaction, semiconductor preparation details, photoreactor configurations, photooxidation kinetics/mechanisms and comparison with other Advanced Oxidation Processes (e.g., UV/H2O2, ozonation, UV/O3, Fenton and photo-Fenton reactions), visible light-induced dye decomposition by sensitization mechanism, reaction intermediates and toxicity issues, and real-world process scenarios. © 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the influence of cleaning pits and fissures with an aluminum oxide air abrasion system on the detection of occlusal caries in primary teeth using laser fluorescence (LF) and visual examination. Methods: The sample comprised 65 pit and fissure sites on extracted primary teeth suspected to be carious. The sites were submitted to 2 visual examinations (examiner JAR) and 2 LF readings (examiner TMV). Next, the occlusal surfaces were air-abraded and re-examined thereafter using both methods. The teeth were sectioned, and the histological analysis of the sites with a stereoscopic magnifying lens at X32 magnifi cation was used as the gold standard. Results: Cohen's kappa statistic for LF and visual examination were, respectively, 0.282/0.884 before and 0.896/0.905 after air abrasion. LF showed a sensitivity of 0.28 increasing to 0.49 and a specifi city of 0.50 increasing to 0.92. Visual examination showed sensitivity of 0.78 and specifi city of 0.73. Both increased after air abrasion. Conclusion: The findings suggest that cleaning pits and fissures with aluminum oxide air abrasion increased the accuracy of LF and visual examination for detection of occlusal caries in primary teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of inks containing organic solvents by the offset printing process implies in the release of volatile organic compounds to the work environment. Many of these compounds such as benzene, toluene, ethylbenzene, and the xylene isomers (well known by the acronym BTEX) are extremely toxic. In this study, the BTEX concentrations were determined in two different printing plants that use distinct types of inks: the conventional and the so-called ecological, which is manufactured based on vegetal oil. Concentration ranges were 43-84, 15-3,480, 2-133, 5-459, and 2-236 μg m-3 for benzene, toluene, ethylbenzene, m + p-xylene, and o-xylene, respectively, for the conventional printing plant. At the ecological printing plant, concentration ranges were below limit of detection (

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The promotion of good indoor air quality in schools is of particular public concern for two main reasons: (1) school-age children spend at least 30% of their time inside classrooms and (2) indoor air quality in urban areas is substantially influenced by the outdoor pollutants, exposing tenants to potentially toxic substances. Two schools in Curitiba, Brazil, were selected to characterize the gaseous compounds indoor and outdoor of the classrooms. The concentrations of benzene, toluene, ethylbenzene, and the isomers xylenes (BTEX); NO2; SO2; O3; acetic acid (HAc); and formic acid (HFor) were assessed using passive diffusion tubes. BTEX were analyzed by gas chromatography-ion trap mass spectrometry and other collected gasses by ion chromatography. The concentration of NO2 varied between 9.5 and 23 μg m-3, whereas SO2 showed an interval from 0.1 to 4.8 μg m-3. Within the schools, BTEX concentrations were predominant. Formic and acetic acids inside the classrooms revealed intermediate concentrations of 1.5 μg m-3 and 1.2 μg m-3, respectively. © Springer Science + Business Media B.V. 2009.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a methodology based on Unconstrained Binary Programming (UBP) model and Genetic Algorithms (GAs) is proposed for estimating fault sections in automated distribution substations. The UBP model, established by using the parsimonious set covering theory, looks for the match between the relays' protective alarms informed by the SCADA system and their expected states. The GA is developed to minimize the UBP model and estimate the fault sections in a swift and reliable manner. The proposed methodology is tested by utilizing a real-life automated distribution substation. Control parameters of the GA are tuned to achieve maximum computational efficiency and reduction of processing time. Results show the potential and efficiency of the methodology for estimating fault section in real-time at Distribution Control Centers. ©2009 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The purpose of this study was to compare the effectiveness of a high-volume evacuation and a conventional intraoral suction system and aspirating tips for capturing aluminum oxide particles during use of an air-abrasion device. Methods: A phantom head was fixed at the dental chair head with secured a metallic device with 5 horizontal shafts, corresponding to operator's clockrelated working positions, and one vertical shaft to simulate the operator's nasal cavity. Petri plates were fixed to the shafts at distances of 20, 40 and 60 cm from the center of the oral cavity of the phantom head to collect the aluminum oxide particles spread over during air abrasion. The dust was aspirated with two types of suction tips used with both suction systems: a conventional saliva ejector and a saliva ejector customized by the adaptation of a 55-mm-diameter funnel. Results: The amount of particles showed that the greatest abrasive particle deposition occurred at a distance of 20 cm from the center of the oral cavity of the phantom head at 9 o'clock operatory position with the conventional saliva ejector attached to high-volume evacuation system. Conclusions: The greatest deposition of aluminum oxide particles occurred at the shortest distance between the operator and the center of the oral cavity, while using the high-volume evacuation system associated to the conventional suction tip.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aiming at improving the efficiency control of Phakopsora pachyrhizi, this research evaluated different application techniques, using spray deposits and yield parameters of soybean crop. Two experiments were carried out in the experimental area of FCA/UNESP - Botucatu, SP, Brazil, in the soybean crop, Conquista variety, in the 2006/2007 season. The first experiment was arranged in random blocks with eight treatments and four replications. The treatments were conducted in factorial arrangement 4×2 (four air levels 0, 9, 11 and 29 km/h combined at two nozzle angles 0 and 30°) using AXI 110015 nozzles. Ten plants on each plot were selected for sampling spray deposits. Artificial targets were fixed on plants, two in the top and another two in the bottom part of plants (abaxial and adaxial leaf surface each one). For deposit evaluations, a cupric tracer was used and the amount of deposits was determined by a spectrophotometer. The second experiment was carried out in the same place and the treatments were of the same arrangement as the previous experiment, including control treatment (untreated plants). The spraying with triazole fungicide was realized in R2 and R5.2 growth stages of soybean with 142 l/ha spray volume. The nozzle angled of 30° combined with maximum air speed promoted the highest spray deposits on the soybean crop and influenced positively the control of the soybean Asian rust as well in the productivity of this crop.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, one of factors that cause the production cost increase of soybean crop is the pesticide application. The most important disease in soybean crop is Asian rust, caused by Phakopsora pachyrhizi Sydon & P. Sydon fungus, which can cause significant loss of the production. Therefore, this work aimed at evaluation of different spraying techniques on the spray deposits and some parameters of soybean crop: grain size, weight of 1 000 seeds and the crop productivity. Two experiments were carried out in the experimental area of FCA/UNESP (Faculdade de Ciencias Agronomicas/Universidade Estadual Paulista Julio de Mesquita Filho) - Botucatu, S P, Brazil, in soybean crop, Conquista variety, in the 2007/2008 season. In the first experiment, three air levels (0, 9 and 29 km/h of the air speed generated by fan) with flat fan nozzle XR 8002 with a spray volume of 130 l/ha were compared with a rotating nozzle - using low volume oily - LVO at 40 l/ha of spray volume. The second experiment was carried out under the same conditions as the previous experiment, including a control treatment (untreated plants). The disease severity was evaluated using a diagrammatic scale with a visual evaluation of the disease on 15 leaves of each plot. The grades varied between 0.6 and 78.5% of the disease severity. The use of air assistance when compared with the rotating system nozzle did not show significant differences for spray deposits on adaxial and abaxial surface of the leaves in bottom part of the plant. The air assistance with maximum air speed (29 km/h) increased the productivity with respect of the other treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a general way, in an electric power utility the current transformers (CT) are used to measurement and protection of transmission lines (TL) 1 The Power Line Carriers systems (PLC) are used for communication between electrical substations and transmission line protection. However, with the increasing use of optical fiber to communication (due mainly to its high data transmission rate and low signal-noise relation) this application loses potentiality. Therefore, other functions must be defined to equipments that are still in using, one of them is detecting faults (short-circuits) and transmission lines insulator strings damages 2. The purpose of this paper is to verify the possibility of using the path to the ground offered by the CTs instead of capacitive couplings / capacitive potential transformers to detect damaged insulators, since the current transformers are always present in all transmission lines (TL's) bays. To this a comparison between this new proposal and the PLC previous proposed system 2 is shown, evaluating the economical and technical points of view. ©2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated, by scanning electron microscope (SEM) and EDS, the effect of different strategies for silica coating (sandblasters, time and distance) of a glass-infiltrated ceramic (In-Ceram Alumina). Forty-one ceramic blocks were produced. For comparison of the three air-abrasion devices, 15 ceramic samples were divided in three groups (N.=5): Bioart, Microetcher and Ronvig (air-abrasion parameters: 20 s at a distance of 10 mm). For evaluation of the time and distance factors, ceramic samples (N.=5) were allocated in groups considering three applied times (5 s, 13 s and 20 s) and two distances (10 mm and 20 mm), using the Ronvig device. In a control sample, no surface treatment was performed. After that, the micro-morphologic analyzes of the ceramic surfaces were made using SEM. EDS analyzes were carried out to detect the % of silica on representative ceramic surface. ANOVA and Tukey tests were used to analyze the results. One-way ANOVA showed the silica deposition was different for different devices (P=0.0054). The Ronvig device promoted the highest silica coating compared to the other devices (Tukey test). Two-way ANOVA showed the distance and time factors did not affect significantly the silica deposition (application time and distance showed no statistical difference). The Ronvig device provided the most effective silica deposition on glass-infiltrated alumina ceramic surface and the studied time and distance for air-abrasion did not affect the silica coating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brazil has an important role in the biomass burning aerosol activity. During the Dry Season (June-September) of 2009 an aerosol profiling campaign was carried out using a backscattering and Raman lidar system in Rio Claro-SP, Brazil (22°23'S and 47°32'W). The main goal of this campaign was to observe the biomass burning aerosol load due to sugarcane crops and also study the air dispersion conditions, planetary boundary and mixed layer daily evolution. In this paper we aim to present the preliminary results of the influence of this type of aerosol over the city of Rio Claro-SP, Brazil and one case study to evaluate the aerosol profile in a biomass burning episode that occurred in July, 2009. On July 15 an intense burning was observed about 300 m away from the lidar location. Throughout the measurements it was observed that the plumes reached up to 900 m, and that there was a time gap between the plumes. The gas analyzers showed a strong influence of this burning as it was noticed in the measurements of CO, NO x and nephelometer, whereas the PM10 did not have due to this burning, possibly because the particulate was deposited further from the emission source, not being detected by the equipment. © Sociedad Española de Óptica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a methodology for optimized allocation of switches for automatic load transfer in distribution systems in order to improve the reliability indexes by restoring such systems which present voltage classes of 23 to 35 kV and radial topology. The automatic switches must be allocated on the system in order to transfer load remotely among the sources at the substations. The problem of switch allocation is formulated as nonlinear constrained mixed integer programming model subject to a set of economical and physical constraints. A dedicated Tabu Search (TS) algorithm is proposed to solve this model. The proposed methodology is tested for a large real-life distribution system. © 2011 IEEE.