109 resultados para Agente retardante de chama
Resumo:
Worldwide environmental degradation is an undesirable byproduct resulting from the increasing demand for natural resources. Water sources are suffering intense contamination since they usually receive a huge amount of domestic and industrial effluents - which are mostly wasted without proper treatment - inserting a large number of pollutants in the environment, heavy metals included. Mercury holds great toxicological importance because, under some physicochemical conditions in a water environment, Hg (II) ion turns into methylated compounds stemming from this element, such as methylmercury CH3Hg, which is highly toxic for the aquatic community in which bioaccumulation occurs. Nowadays passive sampling techniques are being developed to enable the analytical procedures which are applied in environmental monitoring. Diffusive gradients in thin-films technique (DGT) has been proven an interesting tool for the determination of labile metal species due to its in situ application. The DGT technique consists of a piston-like device on which the following series of agents is disposed: a binding agent (conventionally Chelex 100 resin), a diffusive agent, usually a polyacrylamide gel, and a membrane filter. Nevertheless, the agents conventinally used for this technique don't usually show satisfactory results in mercury sampling. The main goal of this study was to evaluate the phosphate-treated cellulose membrane (Whatman P 81), an alternative material, as binding agent in the DGT to determine labile mercury fractions in aquatic systems. In this context, we conducted a study of the behavior of this material in relation with system variables, pH and ionic strength. Afterwards we performed immersions of the DGT devices in real and enriched samples and in situ aiming the determination of mercury
Resumo:
Pós-graduação em Agronomia (Genética e Melhoramento de Plantas) - FCAV
Resumo:
Pós-graduação em História - FCLAS
Resumo:
The aluminum includes several properties with excellent relation between weight and mechanical resistance. With technological advances, increasingly demand the development of new alloys and other production processes in order to reduce the cost of production and insert these new alloys in broader applications. The process of continuous caster (TRC promoted the unite of the aluminum smelting process with the first stage of rolling, making it most economical through the merger these two phases besides transform the continuous casting process. The AA8xxx series is one of the most versatile aluminum alloys and the most often used in continuous caster process provided a great potential application in the market. In order to further, optimize the process it is necessary to increase awareness of the aluminum solidification phenomena associated with the addition of grain refiner, and control of some aluminum production parameters in the process (production rate, metal temperature, etc.). In this study, AA8011 alloy samples were taken in the raw state obtained by the continuous casting process. The samples were laminated to a thickness of 7mm during the process itself and analyzed at three points along its width by microstructural analysis throughout its thickness, the variation rate of addition of the grain refiner in order to assess the influence of this addition with crystallographic formation and some formation of intermetallic precipitates during the solidification. Through this work, it was possible to improve the knowledge related to the addition of refiner with the monitoring of these production processes
Resumo:
Objective: The objective of this paper was to verify if the final irrigation at 17% EDTA, separately or followed by chlorhexidine digluconate at 2% interferes on the apical marginal leakage in root canal overfilling, due to the use of two root canal filling materials (Sealer 26TM or SealapexTM). Methods: Forty lower incisors extracted, with a single root canal, were biomechanically prepared, at 2.0mm beyond the radicular apex, with ProTaper SystemTM, finishing it with the F3 instrument. Irrigation was accomplished with 1.0 mL NaOCl at 2.5% at each change of equipment caliper and, in the end, with 5.0 mL normal saline solution. After achieving this procedure, the foraminal channels was standardized with a file K 25 until its DO appears in the foraminal opening. From this moment, the teeth were subdivided into two groups of 20 specimens each, because of the final irrigation method used: I – irrigation with EDTA at 17% for 3min and II – identical protocol, thus, after EDTA aspiration at17%, it was again irrigated with chlorhexidine digluconate at 2%, also kept intra-canal for 3min. Each group was again sub-divided into two sub-groups (ten teeth each), according to the cement used (Sealer 26TM or SealapexTM), and filled by using a single gutta-percha F1 (ProTaperTM, Universal Filling), in such a manner that it goes 2.0 mm beyond the radicular apex. Soon after that, the teeth were immersed in Rhodamine BTM for 72h, vacuum and after the roots have been bucolingually grooved, the leakages marked were measured with program Image ToolTM. Results and Conclusions: The leakage magnitude was similar among themselves (p > 0.05), except for group Sealapex®, thus the final use with chlorhexidine reduced apical leakage (p < 0.05).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
There is little information regarding bond strengths of polyglass to metal alloys. This study evaluated the influence of bonding system on shear bond strength of a composite resin (Artglass/Heraeus Kulzer) to cast titanium (Ti). Twenty metallic structures (4mm in diameter, 5mm thick) of titanium grade I were cast shaped and abraded with 250mm aluminum oxide and separated into two groups. For each group was applied one bonding system (Siloc or Retention Flow) before opaque and dentin polymer superposition. This procedure was managed using teflon matrices. They were manipulated and polymerized according to the manufacturer's recommendations. The samples were stored in distilled water for 24 hours at 37º and thermocycled (5º and 55ºC/500 cycles). Shear bond strength tests were performed by using an Instron Universal testing machine at a crosshead speed of 5mm/min. Results were analyzed statistically with one-way ANOVA (a=0,5) and they indicated that the Retention Flow system was statistically better than Siloc (20.74 MPa and 11.65 MPa , respectively). It was possible to conclude that the bonding agent influenced the adhesion between polymer and cast titanium.
Resumo:
Sabendo-se do potencial de toxicidade do mercúrio, mais especificamente de sua forma orgânica, o metilmercúrio (MeHg), faz-se necessária a busca por métodos analíticos eficientes e precisos para a determinação e especiação do metal. A técnica de difusão por gradiente em filmes finos (DGT) já vem sendo utilizada para tal fim de maneira eficiente tendo apresentado resultados satisfatórios em diversos estudos. Porém, a utilização de ligantes alternativos aos convencionais, que tornem a aplicação da técnica menos custosa em termos laborais e financeiros, faz-se importante para um monitoramento constante e eficiente do metilmercúrio no ambiente. No presente trabalho buscou-se avaliar o potencial da levedura Saccharomyces cerevisiae imobilizada em agarose em combinação com a poliacrilamida como agente difusivo para determinação seletiva de MeHg. Os resultados demonstraram-se positivo, com um coeficiente de difusão médio de 7,03 ± 0,77 x 10-6 cm2 s-1. Os resultados demonstraram também baixa influencia do pH, força iônica e outros íons na retenção do analito pelos dispositivos. As recuperações de Hg2+ demonstraram-se insatisfatórios, evidenciando a seletividade dos dispositivos
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work describes instrumental strategies for the determination of Mn in a wide range concentration by high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS F AAS) by means of different atomic lines (primary at 279.482 nm, secondary at 403.075 nm and alternative at 209.250 nm). These lines provided complementary concentration intervals, and large sample dilutions became unnecessary. The proposed method was applied to tap water, metal alloy certified material and foliar fertilizer. Accuracy for secondary line were evaluated by tests of significance (t Student test) with reference materials from the Institute of Technological Research of São Paulo, and the results were in agreement at the 95% confidence level. For primary and alternative lines, recovery is were in the 84-116% range and the RSD were 6.1% for all wavelengths. Analytical curves in the 0.1 - 2.0 mg L-1 (279.482 nm), 2.0 - 25 mg L-1 (403.075 nm), 25 - 500 mg L-1 (209.250 nm) intervals were obtained with linear correlation coefficient better than 0.9991. The detection limits were 3.3x10-3 mg L-1 (279.482 nm), 7.4 x 10-3 mg L-1 (403.075 nm), 3.9 mg L- 1 (209.250 nm). The found Mn concentrations were < 3.3x10-3 mg L-1 (tap water), 1.00 ± 0.04 (% m/m) (alloy IPT 25), 7235 ± 175 mg L-1 (foliar fertilizer 1), 4990 ± 132 mg L-1 (foliar fertilizer 2). A method was developed to detect interference of Fe in the Mn primary line (279.482 nm) using the ratio of absorbances of other lines of the triplet (279.827 nm and 280,108 nm).
Resumo:
This study aimed to evaluate the clinical effectiveness of two bleaching agents without changing the whitening gel during the clinic session 1X45minutos. 10 patients were selected according to the criteria of inclusion and exclusion and upper arch of the patients were divided into two quadrants (n: 10), G1: gel clareador Clàriant Office (hidrogênio35 Angellus) peroxide% (PH) in superior right side (LD) and the gel WhitenessHp Blue (FGM) PH 35% on the superior left side (LE. 2 clinical sessions were accomplished, 45 minutes each, with an interval of one week between sessions. At first the bleaching treatment patients received prophylaxis, molding to guide measurement of color with condensation silicon and the color evaluation through the apparel spectrophotometer VITA Easyshade (Vita Zhanfabrik, Alemanhã). 14 days after the end of the bleaching treatment was performed the measurement final color of the teeth. The patients reported sensitivity in scale 0-4. The result showed that through T Test comparing quadrants presented no statistical differences (p>0,05) in relation to coloration and dental sensibility. It can be concluded that the materials evaluated are effective for bleaching vital teeth with low tooth sensibility.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Ecos da memória: a re-construção da identidade em A misteriosa chama da rainha Loana, de Umberto Eco
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)