128 resultados para 368
Resumo:
Chromatographic and electroanalytical methods were developed to detect and quantify Sudan II (SD-II) dye in fuel ethanol samples. Sudan II is reduced at +0.50 V vs. Ag/AgCl on a glassy carbon electrode using Britton-Robinson buffer (pH 4.0) and N,N-dimethylformamide (70:30, v/v) + sodium dioctyl sulfosuccinate surfactant as supporting electrolyte, due to the azo group. This is the basis for its determination by square-wave voltammetry (SWV). Using the optimized conditions, it is possible to get a linear calibration curve from 3.00×10-6 to 1.80×10-5 mol L-1 (r = 0.998) with limits of detection (LOD) and quantification (LOQ) of 2.05×10-6 and 6.76×10-6 mol L-1, respectively. In addition, the hydroxyl substituent in the SD-II dye is also oxidized at +0.85 V vs. Ag/AgCl, which was conveniently used for its determination by high-performance liquid chromatography coupled to electrochemical detection (HPLC-ED). Under the optimized condition, the SD-II dye was eluted and separated using a reversed-phase column (cyanopropyl, CN) using isocratic elution with the mobile phase containing acetonitrile and aqueous lithium chloride (5.00×10-4 mol L-1) at 70:30 (v/v) and a flow rate of 1.2 mL min-1. Linear calibration curves were obtained from 3.00×10-7 to 2.00×10-6 mol L-1 (r = 0.999) with LOD and LOQ of 3.10×10-8 and 1.05×10-7 mol L-1, respectively. Both methods were simple, fast and suitable to detect and quantify the dye in fuel ethanol samples at recovery values between 83.0 to 102% (SWV) and 88.0 to 112% (HPLC-ED) with satisfactory precision and accuracy.
Resumo:
The present study describes the incorporation of a complexing agent, dithiooxamide, into microcrystalline cellulose for use in the pre-concentration of Cu(II) and Cd(II) ions from aqueous samples. The FTIR spectrum of the adsorbent exhibited an absorption band in the region of 800 cm-1, which confirmed the binding of the silylating agent to the matrix. Elemental analysis indicated the amount of 0.150 mmol g-1 of the complexing agent. The adsorption data were fit to the modified Langmuir equation, and the maximum amount of metal species extracted from the solution, Ns, was determined to be 0.058 and 0.072 mmol g-1 for Cu(II) and Cd(II), respectively. The covering fraction φ, which was 0.39 and 0.48 for Cu(II) and Cd(II), respectively, was used to estimate a 1:2 (metal:ligand) ratio in the formed complex, and a binding model was proposed based on this information. The adsorbent was applied in the pre-concentration of natural water samples and exhibited an enrichment factor of approximately 50-fold for the species studied, which enabled its use in the analysis of trace metals in aqueous samples. The system was validated by the analysis of certified standard (1643e), and the adsorbent was stable for more than 20 cycles, thus enabling its safe reutilization. © 2012 Elsevier B.V. All rights reserved.
Resumo:
A new palladium chelate compound is described for the determination of sulfide in aqueous samples. The reagent, bis(2-aminobenzoate)palladium(II) (PdA 2), was prepared by reaction of tetrachloropalladate (PdCl 4 -) with 2-aminobenzoic acid. The compound was characterized by infrared spectroscopy and CHN elemental analysis. The measurement was based on the selective reaction of PdA 2 with sulfide in an aqueous medium, which quantitatively produced fluorescent 2-aminobenzoate (λ ex=245nm, λ em=410nm). The analytical response was linear in the range 0.10-20.0μmol (S 2-) L -1 (r>0.99), with a limit of detection of 0.075μmolL -1 and repeatability (RSD) of 3.4%. There was no interference from CO 3 2-, NO 3 -, Cl -, SO 4 2-, Br -, NO 2 -, K +, NH 4 +, Na +, citrate or S 2O 8 2-. The fluorescence intensity decreased in the presence of H 3CCOO -, PO 4 3- and SCN -, while OH - caused a positive interference. The new fluorescent compound was successfully applied for the determination of sulfide in synthetic wastewater and natural water sample. The advantages of the proposed palladium chelate are absence of toxic by-products, simple synthesis procedure of reagent and yield reaction of about 85%, easy handling and fast acquirement of analytical signal. © 2012 Elsevier B.V.
Resumo:
Background: Macrophage migration inhibitory factor (MIF) is a pleiotropic cytokine with pro-inflammatory functions and involved in tumorigenesis. The aim of this study was to evaluate the expression and localization of the macrophage MIF in oral squamous carcinoma (OSC). In addition, the relationship between MIF expression and clinicopathological parameters such as survival data, tobacco use, alcohol habits, TNM stage, tumor graduation, and peritumoral inflammatory infiltrate were evaluated. Methods: Using immunohistochemistry, expression and localization of MIF was detected in 44 specimens of OSC. The absolute number and relative proportions of MIF-positive cells detected were also determined separately for tumor parenchyma vs. stroma. All counts were determined from 10 consecutive high-power fields using an integration graticule. Moreover, some parameters were analyzed separately for lip and intra-oral cancers. Results: Migration inhibitory factor-positive cells were observed in both the tumor parenchyma and in inflammatory cells of all specimens. In contrast, MIF expression was not detected in tumoral nests associated with poorly differentiated tumors. In specimens of lip cancer, a greater number of MIF-positive stromal immune cells were detected than in intra-oral cancer specimens (Mann-Whitney test, P = 0.049). Conclusions: Oral squamous carcinoma cells consistently express MIF independent of their location. Lip tumors presented more MIF-positive peritumoral inflammatory cells, similar to control, suggesting that immunological differences in leukocyte activation exist between in lip and intra-oral cancers. © 2012 John Wiley & Sons A/S.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Syphilis is a sexually transmitted infectious disease caused by Treponema pallidum. Cases of syphilis have increased in frequency and are challenging when affecting the elderly. The main causes of increased prevalence of syphilis are sexual promiscuity, lack of knowledge about the disease and decreasing use of barrier protection. Clinically, the oral manifestation of syphilis may resemble other entities, which hampers the correct diagnosis. We report a case of a 79-year-old male with weight loss and feeding difficulties. In the oral cavity there were ulcerative lesions in the hard palate and bilaterally in the buccal mucosa. The incisional biopsy revealed only a non-specific ulceration of the oral mucosa. After 20 days, the patient was re-evaluated and presented maculopapular lesions in the palmar and plantar areas. Positive serological venereal disease reference laboratory (VDRL) tests confirmed the diagnosis of secondary syphilis. The patient was treated with Benzathine penicillin G. After two weeks of treatment the oral lesion disappeared and the patient returned to normal feeding and gained weight. This case report reinforces the need to alert physicians and dentists to include sexually transmitted infections such as syphilis in the differential diagnosis of oral ulcerative lesions in elderly sexually active patients. © 2013 Australian Dental Association.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em História - FCHS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Este trabalho trata sobre a calibração de um aparelho baseado na técnica TDR para estudos do fluxo de água em solo não saturado, com base na medição indireta da umidade, sucção matricial (ψ) e condutividade hidráulica não saturada k(ψ), num perfil de solo inalterado. Isto é possível mediante ensaios de laboratório decorrentes da mecânica de solos tradicional e não saturada, a partir de amostras indeformadas retiradas a diferentes profundidades durante a construção de um poço, onde foram instaladas as sondas do TDR. Dos ensaios, obtiveram-se equações polinomiais para relacionar o comportamento da variação do período de tempo do pulso eletromagnético percorrido pela sonda TDR com a variação da umidade do solo e modelos de van Genuchten (1980) para relacionar a umidade com (ψ) e k(ψ). Os resultados mostraram que, para a calibração da umidade neste tipo de solos, um ajuste polinomial de quarto grau se apresenta como melhor alternativa em relação às expressões existentes em lugares onde foram derivadas estas teorias. Adicionalmente, se observou, que as maiores variações de (ψ) e k(ψ). ocorrerão entre a saturação e 10% de umidade devido à peculiaridade da curva de retenção. Finalmente, a presente calibração se apresenta como um expediente útil e prático para estudos hidrodinâmicos de solos não saturados. Palavras-chave: calibração, reflectômetro, teor de umidade, solo não saturado.