126 resultados para transpiration water balance
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The study aimed to determine the coefficient of the yellow passion fruit cultivation and irrigation set capable of increasing crop productivity and quality of production in the environmental conditions of the semi-arid region of Piauí. The experiment was conducted in the Pilot Project for Fruit Crops Irrigated area in Santa Rosa, PI. We used a randomized block design with six treatments and four replications. Treatments (irrigation) were defined according to percentages of reference evapotranspiration (ETo): T1 25%, T2: 50%, T3: 75%, T4: 100%; T5: T6 and 125%: 150%. For monitoring water in the soil profile was used tensiometers. To determine the crop coefficient (Kc) used the water balance in the soil treatment based on 100% replacement of water. Morphological and physiological characteristics of yellow passion fruit were evaluated. The maximum yield of 27.052 kg ha-1 yr-1 was obtained by applying a water depth of 763.80 mm. The values of average fruit weight ranged from 0.207 kg (T6) and 0.159 kg (T1). The average kc obtained for the vegetative stage was 0.57 to 0.94 and flowering stage to fruiting phase 1.04. The water depth of greater efficiency comprise in the range of 75% and 100% ETo.
Resumo:
Knowing the annual climatic conditions is of great importance for appropriate planning in agriculture. However, the systems of climatic classification are not widely used in agricultural studies because of the wide range of scales in which they are used. A series with data from 20 years of observations from 45 climatological stations in all over the state of Pernambuco was used. The probability density function of the incomplete gamma distribution was used to evaluate the occurrence of dry, regular and rainy years. The monthly climatic water balance was estimated using the Thornthwaite and Mather method (1955), and based on those findings, the climatic classifications were performed using the Thornthwaite (1948) and Thornthwaite and Mather (1955) for each site. The method of Kriging interpolation was used for the spatialization of the results. The study classifications were very sensitive to the local reliefs, to the amount of rainfall, and to the temperatures of the regions resulting in a wide number of climatic types. The climatic classification system of Thornthwaite and Mather (1955) allowed efficient classification of climates and a clearer summary of the information provided. In so doing, it demonstrated its capability to determine agro climatic zones.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
O experimento foi realizado no Departamento de Produção Vegetal da Escola Superior de Agricultura Luiz de Queiroz, ESALQ/USP, Piracicaba, São Paulo, Brasil, utilizando-se as culturas de guaranazeiro (Paullinia cupana Kunth), cafeeiro (Coffea arabica L.), cajueiro (Anacardium occidentale L.), goiabeira (Psidium guajava L.) e seringueira (Hevea brasiliensis Muell. - Arg.). No período de seca (setembro/94) e de chuvas (novembro/94), realizaram-se determinações de resistência estomática (RE) (s cm-1) e transpiração (T) (µg cm-1 s-1) nas diferentes espécies. O delineamento experimental foi em blocos casualizados com cinco repetições. A partir das análises dos dados pode-se concluir: 1. diferenças significativas entre espécies, em termos das variáveis avaliadas no período de deficiência hídrica, com valores decrescentes de resistência estomática e crescente de transpiração na seguinte ordem: guaranazeiro > cafeeiro > cajueiro > goiabeira > seringueira; 2. Nas águas as diferenças entre espécies, para ambas as variáveis, foram menos evidentes, continuando a cultura da seringueira a apresentar menor resistência estomática e maior transpiração dentre as espécies; 3. As culturas de guaraná e café apresentaram maior resistência à perda de água, em relação às demais culturas.
Resumo:
M.R. Rocha-Pereira, A.E. Klar, D. Martins, G.S. Ferreira de Souza, and J. Villalba. 2012. Effect of water stress on herbicide efficiency applied to Urochloa decumbens. Cien. Inv. Agr. 39(1): 211-220. This project aimed to measure the control efficiency of Acctil Coenzime A Carboxilase (ACCase)-inhibiting herbicides post-emergence applied to Urochloa decumbens (Stapf) R.D. Webster under different soil water contents. The experiment was conducted in a greenhouse at the Department of Plant Production, Faculty of Agronomic Sciences, UNESP, Botucatu, Silo Paulo. The experimental design was a completely randomized design with four replications, consisting of a 9 x 4 factorial, combined with three water management systems (-0.03, -0.07 and -1.5 MPa) and three herbicides (fluazifop-p-butyl, haloxyfop-methyl and sethoxydim + oil using four doses (100, 50, 25 and 0% of the recommended dose). Herbicide applications were conducted at two vegetative stages for all species: a 4-6 leaf stage and a 2-3 tiller stage. The physiological parameters evaluated were as follows: photosynthetic rate, stomatal conductance, transpiration, leaf temperature and plant dry matter. The visual assessments of phytotoxicity were performed 28 days after herbicide application. The control efficiency was lower in plants grown under soil water potential conditions of -1.5 MPa, regardless of the herbicide used during the two application stages; however, none reached 100% control. Fractionation of the recommended herbicide doses reduced effectiveness, with the exception of the 50%-dose application of sethoxydim and fluazifop-p-butyl herbicides, which were also effective in the 4-6 leaf plant control under normal water conditions.
Resumo:
Wood gasification technologies to convert the biomass into fuel gas stand out. on the other hand, producing electrical energy from stationary engine is widely spread, and its application in rural communities where the electrical network doesn't exist is very required. The recovery of exhaust gases (engine) is a possibility that makes the system attractive when compared with the same components used to obtain individual heat such as electric power. This paper presents an energetic alternative to adapt a fixed bed gasifier with a compact cogeneration system in order to cover electrical and thermal demands in a rural area and showing an energy solution for small social communities using renewable fuels. Therefore, an energetic and economical analysis from a cogeneration system producing electric energy, hot and cold water, using wooden gas as fuel from a small-sized gasifier was calculated. The energy balance that includes the energy efficiency (electric generation as well as hot and cold water system; performance coefficient and the heat exchanger, among other items), was calculated. Considering the annual interest rates and the amortization periods, the costs of production of electrical energy, hot and cold water were calculated, taking into account the investment, the operation and the maintenance cost of the equipments. Crown Copyright (C) 2010 Published by Elsevier Ltd. All rights reserved.
Resumo:
We investigated the effects of injection into the supraoptic nucleus (SON) of losartanand PD 123319 (nonpeptide AT(1) and AT(2)- angiotensin II [ANG II] receptor antagonists, respectively); d(CH2)(5)-Tyr(Me)-AVP (AVPA; an arginine-vasopressin [AVP] V-1 receptor antagonist), FK 409 (a nitric oxide [NO] donor), and N-W-mtro-(L)-arginine methyl ester ((L)-NAME; an NO synthase inhibitor) oil water intake, sodium chloride 3% (NaCl) intake and arterial blood pressure induced by injection of ANG 11 into the lateral septal area (LSA). Mate Holtzman rats (250-300 g) were implanted with cannulae into SON and LSA unilaterally. The drugs were injected in 0.5 mul over 30-60 s. Controls were injected with a similar volume of 0.15 M NaCl. ANG II was injected at a dose of 10 pmol. ANG II antagonists and AVPA were injected at doses of 80 nmol. FK 409 and (L)-NAME were injected at doses of 20 and 40 mug, respectively. Water and NaCl intake was measured over a 2-h period. Prior administration of losartan into the SON decreased water and NaCl intake induced by injection of ANG II. While there was a decrease in water intake, ANG II-induced NaCl intake was significantly increased following injection of AVPA. FK 409 injection decreased water intake and sodium intake induced by ANG II. L-NAME alone increased water and sodium intake and induced a pressor effect. (L)-NAME-potentiated water and sodium intake induced by ANG II. PD 123319 produced no changes in water or sodium intake induced by ANG II. The prior administration of losartan or AVPA decreased mean arterial pressure (MAP) induced by ANG II. PD 123319 decreased the pressor effect of ANG II to a lesser degree than losartan. FK 409 decreased the pressor effect of ANG II while (L)-NAME potentiated it. These results suggest that both ANG II AT, and AVP V, receptors and NO within the SON may be involved in water intake, NaCl intake and the pressor response were induced by activation of ANG II receptors within the LSA. These results do not support the involvement of LSA AT(2) receptors in the mediation of water and NaCl intake responses induced by ANG II, but influence the pressor response. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The circumventricular structures and the lateral hypothalamus (LH) have been shown to be important for the central action of angiotensin II (ANGII) on water and electrolyte regulation. Several anatomical findings have demonstrated neural connection between circumventricular structures and the LH, the present experiments were conducted to investigate the role of the alpha-adrenergic antagonists and agonistic injected into the LH on the water intake, sodium and potassium excretion elicited by injections of ANGII into the lateral ventricle (LV), the water intake was measured every 30 min over a period of 120 min. The sodium, potassium and urinary volume were measured over a period of 120 min in water-loaded rats. The injection of ANGII into the LV increased the water intake, which was reduced by previous injection of clonidine (an alpha-2-adrenergic agonist) into the LH. The injection of yohimbine (an alpha-2-adrenergic antagonist) and prazosin (an alpha-l-adrenergic antagonist) into the LH, which was done before injecting ANGII into the LV, also reduced the water intake induced by ANGII. The injection of ANGII into the LV reduced the sodium, potassium and urinary volume. Previous treatment with clonidine attenuated the action of ANGII in reducing the sodium, potassium and urinary volume, whereas previous treatment with yohimbine attenuated the effects of ANGII but with less intensity than that caused by clonidine. Previous treatment with prazosin increased the inhibitory effects of ANGII in those parameters. The injection of yohimbine and prazosin, which was done before the injection of clonidine, attenuated the effect of clonidine on the ANGII mechanism. The results of this study led us to postulate that when alpha-2-adrenergic receptors are blocked, the clonidine may act on the imidazoline receptors to produce its effects on the ANGII mechanism. We may also conclude that the LH is involved with circumventricular structures, which present excitatory and inhibitory mechanisms. Such mechanisms are responsible for regulating the renal excretion of sodium, potassium and water, (C) 2000 Elsevier B.V.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)