164 resultados para tractive efficiency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gerbil (Meriones unguiculatus) is a rodent native of the and regions of Mongolia and China. Because the gerbil can be easily bred in laboratory conditions, this species has been largely used as an experimental model in biomedical research. However, there is still little information concerning the testis structure and function in the gerbil. In this regard, we performed a detailed morphofunctional analysis of the gerbil testis and estimated the spermatogenic cycle length utilizing H-3-thymidine as a marker for germ cell progression during their evolution through the spermatogenic process. The stage frequencies of the XII stages characterized according to the acrosome formation and development were (I-XII) 13.8, 10.1, 8.1, 7.8, 4.0, 11.2, 7.5, 7.1, 5.9, 7.6, 8.1, and 8.9. The mean duration of each seminiferous epithelium cycle was determined to be 10.6 +/- 1.0 days and the total duration of spermatogenesis, based on 4.5 cycles, was approximately 47.5 days. The volume density of tubular and interstitial compartments was approximately 92% and 8%, respectively. Based on the volume occupied by seminiferous tubules in the testis and the tubular diameter, about 9 and 18 m of seminiferous tubules were found per testis and per gram of testis, respectively. Twelve primary spermatocytes were formed from each type A1 spermatogonia. The meiotic index was 2.8, indicating that 30% of cell loss occurs during meiosis. The number of Leydig and Sertoli cells per gram of the testis was 28 million and each Sertoli cell was able to support approximately 13 spermatids. The daily sperm production per gram of testis (spermatogenic efficiency) was 33 million. Taken together, these data indicate that, mainly due to the high seminiferous tubule volume density and Sertoli cell support capacity for germ cells, the gerbil presents high spermatogenic efficiency compared with other mammalian species already investigated. The data obtained in the present study might provide the basis for future research involving the reproductive biology in this species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work was conducted to evaluate food intake and digestive efficiency of temperate wool and tropic semi-arid hair lambs, according to different concentrate: forage ratios in diet. Twenty-four lambs, averaging 90 +/- 1.8 days old and a mean body weight of 20 +/- 0.69 kg, 12 of them wool lambs, F, from Ideal x Ile de France crossing, and 12 others pure Santa Ines hair lambs, were distributed into a four replication 3 x 2 factorial arrangement consisting of three diets and two genotypes. Experimental diets consisted of: D1 = 60% concentrate mix (C) and 40% Cynodon sp. cv. Tifton-85 hay (F), D2 = 40% C and 60% F, and D3 = 20% C and 80% F. D1 was formulated for a daily gain of 300g per animal. Increasing forage levels in diets resulted in linear reductions (P < 0.01) in DM, OM, CP, TCH and metabolizable energy (ME) intake, and a linear increase (P < 0.01) in NDF ingestion. Tropic semi-arid hair lambs had higher DM, OM, NDF, CP, and TCH intake than temperate wool lambs. Although there were no genotype effects in OM and GE coefficient of digestibility, hair lambs showed more efficient (P < 0.05) digestibility of DM, CP, NDF and TCH. Increases in forage levels of diets corresponded to a negative linear effect (P < 0.01) in the apparent digestibility of DM, OM, CP, TCH and GE, while apparent digestibility of NDF increased linearly (P < 0.01). Total endogenous nitrogen (fecal plus urinary N) for F(1) Ideal x Ilede France wool and Santa Ines hair lambs were, respectively, 182 and 312 mg/kg(0.75) per day. Thus, Santa Ines tropic semi-arid hair lambs showed to be more responsive than F(1) Ideal x Ile de France temperate wool lambs to low quality fibrous diets. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The need for standardization of the measured blow count number N-spt into a normalized reference energy value is now fully recognized. The present paper extends the existing theoretical approach using the wave propagation theory as framework and introduces an analysis for large displacements enabling the influence of rod length in the measured N-spt values to be quantified. The study is based on both calibration chamber and field tests. Energy measurements are monitored in two different positions: below the anvil and above the sampler. Both experimental and numerical results demonstrate that whereas the energy delivered into the rod stem is expressed as a ratio of the theoretical free-fall energy of the hammer, the effective sampler energy is a function of the hammer height of fall, sampler permanent penetration, and weight of both hammer and rods. Influence of rod length is twofold and produces opposite effects: wave energy losses increase with increasing rod length and in a long rod composition the gain in potential energy from rod weight is significant and may partially compensate measured energy losses. Based on this revised approach, an analytical solution is proposed to calculate the energy delivered to the sampler and efficiency coefficients are suggested to account for energy losses during the energy transference process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined the effects of simulated folivory by caterpillars on photosynthetic parameters and nitrogen (N) resorption efficiency in Quercus pyrenaica saplings. We analyzed the differences between intact leaves in control plants, punched leaves in damaged plants, and intact leaves in damaged plants. We then established two levels of simulated folivory: low (approximate to 13% of the leaf area of one main branch removed per plant) and high (approximate to 26% of the leaf area of one main branch removed per plant) treatments. No differences were found in net assimilation rate and conductance between either leaf type or treatment during the most favourable period for photosynthesis. However, the N content was lower in punched than in intact leaves, and as a result PNUE was higher in damaged leaves from treated trees. In leaf-litter samples, N mass was significantly higher in punched than in intact leaves in treated plants, and LMA was significantly higher in damaged than in intact leaves of both the treated and control plants. Consequently, N resorption efficiency was around 15% lower in damaged leaves as compared with intact leaves from treated and control plants. Mechanical injury to leaves not only triggered no compensatory photosynthetic response to compensate a lower carbon uptake due to leaf area loss, but also affected the resorption process that characterizes leaf senescence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We tested the effects of monochromatic light on the specific growth rate (SGR), feed intake and feed efficiency (FE) of juvenile pikeperch, Sander lucioperca (L.). Pikeperch were reared individually for 42 days in aquaria covered with blue, green, yellow or red gelatin filters or white paper (control; n=5). Linear regression analysis indicated a significant positive effect of longer wavelengths of light on the condition factor (CF), FE and SGR. The final weight, SGR and CF were significantly higher in fish reared under red than under white light, and FE was better under green, yellow and red light than under white light (Dunnett's post hoc test, P < 0.05) while blue was comparable to white light in terms of the measured parameters. After the growth trial, the spectral sensitivity of photoreceptor cells in the retina was tested using microspectrophotometry, which revealed the presence of rods with lambda(max) at ca. 530 nm and two cone classes, absorbing maximally at ca. 535 and 603 nm, all containing a porphyropsin-based pigment. These results suggest that the presence of mid and long wavelength-sensitive cones enhances visual sensitivity under mid-wavelength and long-wavelength environments, and thus supports the finding that longer wavelengths of incoming light can improve FE and SGR of the cultivated pikeperch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 99 pregnant cows were divided into eight groups submitted to the following treatments: group I (n = 29) consisted of unvaccinated cows whose calves did not receive a probiotic and was used as control. Group II (n = 10) consisted of vaccinated cows whose calves did not receive a probiotic. Groups III, IV and V (n = 10 neach) consisted of vaccinated cows whose calves received a probiotic for 5, 15 and 30 days, respectively. Groups VI, VII and VIII (n = 10 each) consisted of unvaccinated cows whose calves received a probiotic for 5, 15 and 30 days, respectively. Each animal in the vaccinated groups received two 5.0 ml vaccine doses containing pili K99 and A14 of Escherichia coli by the subcutaneous route. The probiotic containing Lactobacillus acidophilus at the dose of 2.0 x 10(8) live cells in 250 ml milk, was administered orally. All animals were observed clinically and bacteriologically and anti-K99 and anti-A14 antibody titers were determined in serum and colostrum. Mean calf weight was measured at birth and at 30 days of age. The results showed that a combination of the vaccine with the probiotic administered for 15 and 30 days was the most efficient treatment for the control of diarrhea.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of the present study were to evaluate the safety of mixer/loaders and applicators of paraquat to maize crop by knapsack sprayers and to determine the efficacy of safety measures applied to the sprayers. Potential dermal exposure (PDE) was evaluated in 22 worker body parts. The Cu2+ cation of a copper-based fungicide was used as tracer in the spray solution. Sanitary pads and cotton gloves were used to collect the pesticide solution on the sampled body parts. It was observed that paraquat application in front of the applicator's body (0.5 and 1.0 m lance) is unsafe because PDE was 1,979.8 ml/day (for 0.5 m lance) and 1,290.4 ml/day (for 1.0 m lance) and needs 50-80% and 37-69% control of PDE respectively. Control can be achieved by the use of protective garment on the legs and feet only, which received 92-93% of the PDE. Switching the spray nozzle to the back of the operator reduced the PDE by 98% and was sufficient to make working conditions safe, while maintaining the efficiency of application and making the work lighter and more comfortable. Mixer/loaders received 86% of the PDE to the hands and the work condition was safe (MOS > 1), however impermeable gloves could be used as a further safety measure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hrp1p is a heterogeneous ribonucleoprotein (hnRNP) from the yeast Saccharomyces cerevisiae that is involved in the cleavage and polyadenylation of the 3'-end of mRNAs and mRNA export. In addition, Hrp1p is one of several RNA-binding proteins that are posttranslationally modified by methylation at arginine residues. By using-functional recombinant Hrp1p, we have identified RNA sequences with specific high affinity binding sites. These sites correspond to the efficiency element for mRNA 3'-end formation, UAUAUA. To examine the effect of methylation on specific RNA binding, purified recombinant arginine methyltransferase (Hmt1p) was used to methylate Hrp1p. Methylated Hrp1p binds with the same affinity to UAUAUA-containing RNAs as unmethylated Hrp1p indicating that methylation does not affect specific RNA binding. However, RNA itself inhibits the methylation of Hrp1p and this inhibition is enhanced by RNAs that specifically bind Hrp1p. Taken together, these data support a model in which protein methylation occurs prior to protein-RNA binding in the nucleus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low-voltage, low-power four-quadrant analog multiplier with optimized current-efficiency is presented. Its core corresponds to a pseudodifferential cascode, gain-boosting triode-transconductor. According to a low-voltage 1.2μm CMOS n-well process, operand differential-amplitudes are 1.0Vpp and 0.32Vpp for a 1.3V-supply. Common-mode voltages are properly chosen to maximize current-efficiency to 58%. Total quiescent dissipation is 260μW. A range of PSPICE simulation supports theoretical analysis. Excellent linearity is observed on dc characteristic. Assuming a ±0.5% mismatch on (W/L) and VTH THD at full-scale is 0.93% and 1.42%, for output frequencies of 1MHz and 10MHz, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a high efficiency Sepic rectifier for an electronic ballast application with multiple fluorescent lamps. The proposed Sepic rectifier is based on a Zero-Current-Switching (ZCS) Pulse-Width-Modulated (PWM) soft-commutation cell. The high power-factor of this structure is obtained using the instantaneous average-current control technique, in order to attend properly IEC61000-3-2 standards. The inverting stage of this new electronic ballast is a classical Zero-Voltage-Switching (ZVS) Half-Bridge inverter. A proper design methodology is developed for this new electronic ballast, and a design example is presented for an application with five fluorescent lamps 40W-T12 (200W output power), 220Vrms input voltage, 130Vdc dc link voltage, with rectifier and inverter stages operating at 50kHz. Experimental results are also presented. The THD at input current is equal to 6.41%, for an input voltage THD equal to 2.14%, and the measured overall efficiency is about 92.8%, at rated load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was evaluated the energetic efficiency and operational parameters of a windrowing and prismatic baling, both from CASE NEW HOLLAND® operations in sugarcane vegetal residues (green leaves, dry leaves and tops) picked mechanically in green cane. The area belongs to COSTA PINTO MILL (COSAN® Group) which was harvested mechanically by combines in the State of Sao Paulo, Brazil. The geographic location of the area is: Latitude 22°40'30S, Longitude 47°36'38W and Altitude of 605m. The variety was RB 82-5336, planted in 1.40m row spacing, with 78t.ha-1 yield. The vegetal residues analysis obtained 69.93% of leaves, 21.44% of stalks fractions, 2.27% of tops and 6.36% of total strange matter. The vegetal residues values were: gross heat of 18.43MJ.kg-1, low heat of 17.00MJ.kg'1 and useful heat of 12.94MJ.kg-1. The vegetal residues average energetic potential was 342.48GJ.ha-1. The treatments were simple, double and triple windrowing. The use of the rake and prismatic baler to pick up the residues was viable. The simple windrowing treatment presented the best results: effective capacity of 83.06t.ha-1, fuel consumption of 0.18L.t -1 and 99.95% of positive energetic efficiency. The bales obtained in the treatment of triple windrowing presented the largest specific mass average of 221.11kg.m-3. The soil amount in the bales increased with successive windrowing. The baling operation in the triple windrowing treatment obtained better results, presenting the effective capacities of 20.29t.h -1 and 1.45ha.h-1 and fuel consumption of for baled in 1.37L.t-1. The high total energetic efficiency of 99.53% indicates that is technically viable the withdrawal of the vegetal residues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to analyze the sugar cane vegetal residues collection, as well as determining its energetic potential, using a rake and cylindrical baler, both from NEW HOLLAND® under two different windrowing process (simple and double). The field tests were carried out in an area that belongs to COSTA PINTO MILL (COSAN® Group) in the city of Piracicaba, Sao Paulo State, Brazil. The geographic location of the area is: Latitude 22°4030'S, Longitude 47°3633'W and altitude of 605m. From the trash analysis, before the baling, the following average results were obtained: 69.93% of leaves; 2.27% of stalks fractions; 21.44% of tops and 6.36% of total strange matter. The estimated residues yield was 27.01 tons.ha -1 with a gross heat of 18.43 MJ.kg-1, low heat of 17.01 MJ.kg-1, useful heat of 13.32 MJ.kg-1, average moisture of 20.76% and an energetic potential of 494,875.09 MJ.ha-1. In the windrowing operations (simple and double) the averages of the 5 out of 13 analyzed variable presented differences between them in a 1% level of significance in the Tukey Test. The averages comparison of the results for bale's specific mass and the effective capacities (ton.h-1) e (ha.h-1) had been significant at a 5% level in the Tukey Test. The comparisons of the averages for the results had been significant to 1% level. The strange matter averages of the bales did not differed between them.