204 resultados para tactile transducer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aimed to evaluate the endectocide activity of a new injectable long-action formulation, containing ivermectin (IVM) and abamectin (ABA). In each one of the four experiments performed, the following groups were formed: group I: 2.25% IVM (450 mu g/kg) + 1.25% ABA (250 mu g/kg), group II: 3.15% IVM (630 mu g/kg) and group III: control. Eighteen bovine naturally infected by gastrointestinal nematoda were selected for anthelmintic evaluation and necropsied on posttreatment day (PTD) 14 to estimate the total parasitic burden. For the Rhipicephalus (Boophilus) microplus field trial, 30 bovine were selected by means of counts of semi-engorged R. (B.) microplus and the therapeutic and residual efficacy evaluated by tick counts on PTDs 1, 3, 7, 14, 21, 28, 35, 42, 49, 56, 63, 70, 77, 84 and 91. In the stall test, 15 calves were artificially infested with 5000 R. (B.) microplus (Mozzo strain) larvae three times a week and daily collections of all the engorged female ticks detached from each calf were performed until the PTD 80. Forty bovine naturally infected with Dermatobia hominis larvae were selected and the number of larvae was counted by visual and tactile inspection on PTDs 3, 7, 14, 28, 35, 49, 63, 77, 91 and 105. In this trial, a formulation containing 1% doramectin (200 mu g/kg) was also used. IVM + ABA formulation and 3.15% IVM eliminated four of the eight species of nematode identified. The anthelmintic efficacy of the avermectins association against Haemonchus placei, Cooperia spatulata and C. punctata was 89.64%, 98.84% and 97.69%, while 3.15% IVM achieved 30.98%, 84.79% and 75.56%, respectively. The two formulations evaluated showed reduced acaricide action on the PTD I and 3, reaching high efficacy percentages from PTD 14 onward. The IVM + ABA showed efficacy above 95% in the period between PTDs 21 and 49. In the stall test, it observed no difference (P > 0.05) between the two formulations regarding the R. (B.) microplus counts during the entire evaluation period. IVM + ABA reduced the number of ticks from the PTD 1 to 77 (P < 0.05) and 3.15% IVM reduced (P < 0.05) the tick number from PTD 4 up to PTD 80. The three endectocides showed no difference (P > 0.05) regarding the number of D. hominis larvae and prevented this parasite reestablishment until PTD 105. These results indicate that the IVM + ABA association showed higher anthelmintic activity and similar efficacy against arthropods to the formulation containing 3.15% IVM. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Measurements of ultrasonic attenuation and velocity in milk and low concentration water-in-oil (W/O) emulsion were conducted, using a measurement cell with a double-element transducer that eliminates diffraction losses. The milk is characterized by the attenuation coefficient, while in the case of water-in-oil emulsions, the characterization is best represented by the propagation velocity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work it is introduced a new approach to calculate the density of liquids in terms of the energies of the acoustic signals. This method is compared to other methods in the time domain (peak-to-peak amplitudes) and frequency domain magnitudes at a single frequency. It is used a measurement cell based on a multiple reflection technique, and it is developed an acoustic model for the cell. Simulations and experiments using several liquids are presented, showing that the energy method a less sensitive to noise than the other techniques. The relative errors in the density are smaller than 0.2% when compared to the values measured with a pycnometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The instrumentation applied to the Charpy test machine allows the accompaniment of the specimen answer front the impact load, in form of a sign characteristically dynamic representative of the deformation process and it fractures of material tested. The main advantages of the rehearsal conventional Charpy: low cost, manufacturing sample facilities and simple handle the machine. With the instrumentation, the number of information regarding the process of fracture of the specimen increases. In this work discusses the influence of the hammer geometry in determination of the force during the process of specimen fracture submitted to the instrumented impact test Charpy-V. The purpose is obtaining a hammer, in conformity with Norma ISO 14.556, with great sensibility to register the force during the impact. Two geometries different from hammers were instrumented and rehearsed with material of low tenacity, in this case the steel ABNT 4140 in the condition of having normalized. It could be proven as larger the sensibility of the hammer, adult will be the effects of the shock waves in the strain gages of the transducer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 1000-kgf resistive strain-gauge load cell has been developed for quality testing of rocket propellant grain. A 7075-T6 aluminum alloy has been used for the elastic column, in which 8 uniaxial, 120-Ω strain gauges have been bonded and connected to form a full Wheatstone bridge to detect the strain. The chosen geometry makes the transducer insensitive to moments and, also, to the temperature. Experimental tests using a universal testing machine to imposed compression force to the load cell have demonstrated that its behavior is linear, with sensitivity of 2.90 μV/kgf ± 0.34%, and negligible hysteresis. The designed force transducer response to a dynamic test has been comparable to that of a commercial load cell. © 2005 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the shelf-life of peeled giant river prawn Macrobrachium rosenbergii stored directly in contact with ice (DCI), and without direct contact with ice (WCI). The prawns from DCI treatment showed an intense leaching of non-protein nitrogen (NPN) and total volatile bases nitrogen (TVB-N), thus suggesting that NPN or TVB-N should not be used as freshness indicators of peeled tails stored directly in contact with ice. Loss of flavor and a quick texture tactile decrease with time occurred in both treatments. The shelf-life of peeled tails prepared from M. rosenbergii was 7 days for DCI and 10 days WCI. © 2006 by The Haworth Press, Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In practical situations, the dynamics of the forcing function on a vibrating system cannot be considered as given a priori, and it must be taken as a consequence of the dynamics of the whole system. In other words, the forcing source has limited power, as that provided by a DC motor for an example, and thus its own dynamics is influenced by that of the vibrating system being forced. This increases the number of degrees of freedom of the problem, and it is called a non-ideal problem. In this work, we considerer two non-ideal problems analyzed by using numerical simulations. The existence of the Sommerfeld effect was verified, that is, the effect of getting stuck at resonance (energy imparted to the DC motor being used to excite large amplitude motions of the supporting structure). We considered two kinds of non-ideal problem: one related to the transverse vibrations of a shaft carrying two disks and another to a piezoceramic bar transducer powered by a vacuum tube generated by a non-ideal source Copyright © 2007 by ASME.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose new circuits for the implementation of Radial Basis Functions such as Gaussian and Gaussian-like functions. These RBFs are obtained by the subtraction of two differential pair output currents in a folded cascode configuration. We also propose a multidimensional version based on the unidimensional circuits. SPICE simulation results indicate good functionality. These circuits are intended to be applied in the implementation of radial basis function networks. One possible application of these networks is transducer signal conditioning in aircraft and spacecraft vehicles onboard telemetry systems. Copyright 2008 ACM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We studied the reproductive biology and visual signaling of Dendropsophus werneri, whose distribution is limited to the Atlantic Rain Forest. The fieldwork was carried out in the Estação 2 do IAPAR, municipality of Morretes, state of Paraná, Brazil, from August 2006 to March 2007. Additional information on reproduction was gathered in the Reserva Natural Salto Morato, municipality of Guaraqueçaba, state of Paraná, Brazil, from September 2006 to March 2007. Males were smaller than females. Males called throughout all the study period in Morretes, but were active only during three months in Guaraqueçaba; males called from low vegetation along the edge of temporary ponds in open areas. The visual signaling was observed in two contexts: (1) aggressive behaviors between two males and (2) during the reproduction, by amplectant males. In the territorial behavior, males exhibited both aggressive and mixed calls, visual signaling as well as physical combats. We also recorded satellite behavior in four males. The mean egg number per clutch was 244 ± 32 eggs, varying between 188 and 310 eggs. We observed two reproductive modes: Mode 1 and Mode 24. In the present study, Dendropsophus werneri showed elaborated social interactions involving visual signaling, territorial behavior, mating bahavior with tactile stimuli, and two different reproductive modes, demonstrating its complex reproductive biology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Occlusion is a predisposing factor for Temporomandibular Dysfunctions (TMD) of the joint, whose first sign and/or symptom is usually joint sound. To verify the effect of occlusion on joint sounds, temporomandibular joints (TMJ) were analyzed in 78 asymptomatic individuals with various dental conditions. Electrosonography was used to determine the intensity of the vibration in the temporomandibular joint (TMJ) on opening and closing the mouth. Transducers (piezoelectric accelerometer) were placed on the right and left joints. Results were tabled and analyzed using the Kruskal-Wallis test (a=0.05). It was concluded that TMJ vibration in partly edentulous individuals from Kennedy classes I, II and III is statistically higher than in dentate and fully edentulous subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of oral rehabilitation with immediately loaded fixed implant-supported mandibular prostheses on chewing and swallowing in elderly individuals. Materials and Methods: Fifteen completely edentulous patients aged more than 60 years (10 women and rive men), wearing removable dentures in both arches, had a mandibular denture replaced by an implant-supported prosthesis. All individuals were evaluated before surgery and again 3, 6, and 18 months later with regard to mastication and swallowing conditions. Examinations entailed an interview, evaluation of tactile sensitivity of the face, and observation of food intake, masticatory type, formations of bolus, and pain during mastication. The swallowing evaluation comprised observation of clinical signs related to the oral and pharyngeal stages of swallowing, as well as the presence of oral residue. The findings of different evaluations before and 3, 6, and 18 months after the surgical-prosthetic procedure were statistically compared by analysis of variance for repeated measurements at a significance level of 5%. Results: The questionnaire revealed a reduction in complaints of masticatory and swallowing disturbances, a decreased need for liquid ingestion, and reduced choking and coughing. Clinical evaluations showed improved oral function and bolus propulsion for both solid and paste-consistency foods; pain during mastication was also resolved. Conclusion: Treatment with mandibular implant-supported dentures had positive effects on the clinical aspects of mastication and swallowing in elderly individuals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of piezocone tests with a slot filter filled with automotive grease for site characterization of tropical soils is assessed. Laboratory tests using the slot filter filled with automotive grease as well as the conventional porous piezo-element saturated with glycerin were carried out to evaluate the pore pressure (u 2) transducer response. CPTu tests using piezo-elements saturated with glycerin and the slot filter filled with grease were pushed side by side in different research sites in Brazil. Estimates of mechanical and hydraulic soil parameters were made based on pore pressure dissipation curves from using both techniques. Laboratory test results indicate that the pore pressure response using the slot filter with grease was delayed when compared to the piezo-element saturated with glycerin, since grease has a higher viscosity. For tropical soils, the records of u2 in piezocone tests using slot filter with grease presented larger peaks than with porous element saturated with glycerin. Records of u2 using the slot filter above the groundwater table suggest the increase of the degree of saturation in unsaturated zone, where porous filter can be desaturated by suction. The slot filter can be used to help the interpretation of the soil profile with deep groundwater level as well as to help detecting its position for some studied soils. The results shown high repeatability for all study sites. This technique is much easier to handle, especially for tropical soils, where the groundwater table is usually deep and pre-drilling is expensive and time consuming. © 2009 IOS Press.