114 resultados para specimen
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Comparative cytogenetic analyses were carried out in six species of Brachycephalidae from southeastern Brazil. Barycholos ternetzi, Eleutherodactylus binotatus, Eleutherodactylus guentheri, Eleutherodactylus juipoca, Eleutherodactylus parvus and Eleutherodactylus sp. have 2n = 22 karyotypes with a marked variation in the morphology of chromosome pairs 8, 10 and 11, which are of telocentric or metacentric types, resulting in FN = 38, 40 and 44. Eleutherodactylus have a single chromosome pair bearing Ag-NOR, i.e. pair 1 in E. binotatus, pair 6 in E. guentheri and E. parvus, and pair 11 in E. juipoca and Eleutherodactylus sp. In contrast, B. ternetzi showed Ag-positive sites in the chromosome pairs 1, 4, 5, 9 and 11, and only one to three labelings per metdphase in each individual. Nevertheless, the main chromosome pair with Ag-NOR in the species seems to be the 11th, like in E. juipoca and Eleutherodactylus sp. The NOR site was confirmed by fluorescence in situ hybridization (FISH) technique in E. binotatus and in B. ternetzi, bearing 1p1p and 9p11p11p Ag-NOR pattern, respectively. All the species exhibited predominantly centromeric C-banding pattern, but interstitial bands have also been observed in some cases. In E. binotatus, there is an indication of geographical difference in the distribution of the interstitial C-bands. The fluorochromes GC-specific chromomycin A(3) (CMA(3)) and AT-specific 4',6-diamidino-2-phenylindole (DAPI), with distamycin A (DA) counterstaining, provided the molecular content of some repetitive regions in the karyotypes of the species. One male of E. binotatus presented an extensive heteromorphism, involving at least five different pairs, probably as a consequence of multiple reciprocal translocations. Such rearrangements might be responsible for the multivalent chain seen in the meiosis of this specimen, as well as in another male, although not exhibiting chromosome heteromorphism. The remaining males and those belonging to the other species have always shown 11 bivalents in diplotene and metaphase I cells. In all male specimens, metaphases II presented 11 chromosomes. Despite the observed discrepancies, the five species of Eleutherodactylus have a great uniformity in the 2n = 22 karyotypes, suggesting an assemblage of species from southeastern and southern Brazil, in contrast to northern and northeastern assemblage which is characterized by higher diploid numbers. Undoubtedly, B. ternetzi could be included in that proposed assemblage, due to its karyotypic similarity with the Eleutherodactylus species, as evidenced in the present study. This fact strongly supports the close relationships of both genera, previously inferred on the basis of several characters shared by their species. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Four records of potamotrygonids in the Uruguay River and its tributaries in Paysandu, Uruguay are reported in this paper. The first one was a specimen caught in 1934, of undetermined sex and weighing 120 kg and with a disc width of ca 150 cm. The second specimen, caught in 1998, was also of undetermined sex; it weighed 50 kg total weight and its disc width measured 103 cm. The third specimen was caught in 2001; it was an adult male, weighed 114 kg total weight and its disc width measured ca 110 cm. The fourth one, caught in 2004, was a female, 11 kg in total weight and with a disc width of 80 cm. According to the size and general description, specimens were identified as Potamotrygon brachyura, to date the only potamotrygonid confirmed for Uruguay.
Resumo:
This study analyses the ontogenetic diet shifts of a Neotropical catfish, Pimelodus maculatus ( Siluriformes, Pimelodidae), from an ecomorphological standpoint. We collected 241 individuals in the Piracicaba River ( Brazil) and, in the laboratory, seven morphometric variables were recorded from each specimen: standard length (SL), body depth, head length, snout length, eye diameter, mouth height and mouth width. After standardizing these measurements ( as a proportion of SL), linear regressions were run to determine whether their growth was isometric or allometric in relation to SL. The diet analysis shows that the main food item for fish in the smaller size classes is aquatic insects, while the largest individuals feed mainly on other fish. As the great majority of the morphometric variables analyzed showed isometric growth as a function of SL - which means that these fish do not change their shape significantly during their lives - the ontogenetic diet shifts may be seen as a consequence of the absolute size increment of their mouth gape, which allows individuals to maximize their energetic gain by ingesting larger prey with a higher caloric content.
Anomalia bilateral no gonóstilo de Sciopemyia sordellii (Shannon & Del Ponte) (Diptera, Psychodidae)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To evaluate the effect of cyclical mechanical loading on the bond strength of a fiber and a zirconia post bonded to root dentin.Materials and Methods: Forty single-rooted human teeth (maxillary incisors and canines) were sectioned, and the root canals were prepared at 12 mm. Twenty randomly seleced specimens received a quartz fiber post (FRC) (D.T. Light-Post) and 20 others received a zirconia post (ZR) (Cosmopost). The posts were resin luted (All Bond 2 + resin cement Duo-link) and each specimen was embedded in epoxy resin inside a PVC cylinder. Ten specimens with FRC post and 10 specimens with ZR post were submitted to fatigue testing (2,000,000 cycles; load: 50 N; angle of 45 degrees; frequency: 8 Hz), while the other 20 specimens were not fatigued. Thus, 4 groups were formed: G1: FRC+O cycles; G2: FRC+2,000,000 cycles; G3: ZR+O cycles; G4: ZR+2,000,000 cycles. Later, the specimens were cut perpendicular to their long axis to form 2-mm-thick disk-shaped samples (4 sections/specimen), which were submitted to the push-out test (1 mm/min). The mean bond strength values (MPa) were calculated for each tooth (n = 10) and data were submitted to statistical analysis (alpha = 0.05).Results: Two-way ANOVA revealed that the bond strength was significantly affected by mechanical cycling (p = 0.0014) and root post (p = 0.0325). The interaction was also statistically significant (p = 0.0010). Tukey's test showed that the mechanical cycling did not affect the bonding of FRC to root dentin, while fatigue impaired the bonding of zirconium to root dentin.Conclusion: (1) the bond strength of the FRC post to root dentin was not reduced after fatigue testing, whereas the bonding of the zirconia post was significantly affected by the fatigue. (2) Cyclical mechanical loading appears to damage the bond strength of the rigid post only.
Resumo:
Statement of problem. Different combinations of Co-Cr alloys bonded to ceramic have been used in dentistry; however, the bond strength of ceramic to metal can vary because of different compositions of these alloys.Purpose. The purpose of this study was to evaluate the shear bond strength of a dental ceramic to 5 commercially available Co-Cr alloys.Material and methods. Five Co-Cr alloys (IPS d.SIGN 20, IPS d.SIGN 30, Remanium 2000, Heranium P, and Wirobond C) were tested and compared to a control group of an Au-Pd alloy (Olympia). Specimen disks, 5 mm high and 4 mm in diameter, were fabricated with the lost-wax technique. Sixty specimens were prepared using opaque and dentin ceramics (VITA Omega 900), veneered, 4 mm high and 4 mm in diameter, over the metal specimens (n = 10). The shear bond strength test was performed in a universal testing machine with a crosshead speed of 0.5 mm/min. After shear bond testing, fracture surfaces were evaluated in a stereomicroscope under x25 magnification. Ultimate shear bond strength (MPa) data were analyzed with 1-way ANOVA and the Tukey HSD test (alpha = .05).Results. The mean (SID) bond strengths (MPa) were: 61.4 (7.8) for Olympia; 94.0 (18.9) for IPS 20; 96.8 (10.2) for I PS 30; 75.1 (12.4) for Remanium; 71.2 (14.3) for Heranium P; and 63.2 (10.9) for Wirobond C. Mean bond strengths for IPS 20 and IPS 30 were not significantly different, but were significantly (P<.001) higher than mean bond strengths for the other 4 alloys, which were not significantly different from each other.Conclusions. Bond strength of a dental ceramic to a Co-Cr alloy is dependent on the alloy composition.
Resumo:
Purpose: The aim of this study was to evaluate the influence of dentin abrasion on the microshear bond strength of two self-etching adhesive systems, using either an ultrasound diamond bur or a high-speed diamond bur.Materials and Methods: Twenty noncarious human third molars were sectioned mesiodistally into halves. The enamel was ground to expose a flat dentin surface on both sections. The dentinal surfaces were randomly assigned to two groups, depending on the method of smear layer preparation: ultrasound diamond bur (UB) or conventional diamond bur (CB). The prepared dentin surfaces received one of two self-etching systems: Clearfil SE Bond (CF) and One-Up Bond F (OB). A composite cylinder with a 0.95-mm diameter was bonded to each specimen and the microshear bond test was performed. The results were expressed in MPa and were subjected to two-way analysis of variance (ANOVA) and Tukey's test (alpha = 0.05).Results: There was no significant difference in dentin bond strength when comparing the conventional and ultrasonic abrasion methods. When the adhesive systems were compared, Clearfil SE Bond achieved higher bond strength means than did One-Up Bond F.Conclusion: The dentin surface preparation method did not influence the microshear bond strength and the Clearfil SE Bond adhesive system, independent of bur type used, Clearfil SE Bond showed higher bond strengths than did the One-Up Bond F adhesive system.
Resumo:
The paper presents the results of an experimental study of interfacial failure in a multilayered structure consisting of a dentin/resin cement/quartz-fiber reinforced composite (FRC). Slices of dentin close to the pulp chamber were sandwiched by two half-circle discs made of a quartz-fiber reinforced composite, bonded with bonding agent (All-bond 2, BISCO, Schaumburg) and resin cement (Duo-link. BISCO, Schaumburg) to make Brazil-nut sandwich specimens for interfacial toughness testing. Interfacial fracture toughness (strain energy release rate, G) was measured as a function of mode mixity by changing loading angles from 0 degrees to 15 degrees. The interfacial fracture surfaces were then examined using Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Spectroscopy (EDX) to determine the failure modes when loading angles changed. A computational model was also developed to calculate the driving forces, stress intensity factors and mode mixities. Interfacial toughness increased from approximate to 1.5 to 3.2 J/m(2) when the loading angle increases from approximate to 0, 0 to 15 degrees. The hybridized dentin/cement interface appeared to be tougher than the resin cement/quartz-fiber reinforced epoxy. The Brazil-nut sandwich specimen was a suitable method to investigate the mechanical integrity of dentin/cement/FRC interfaces. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Purpose: This study evaluated the effect of bleaching gel containing 10%, 15% and 20% carbamide peroxide (CP) on the bond strength of dental enamel or dentin and resin composite restorations.Methods: The buccal surfaces of 12 bovine tooth crowns were conditioned with 37% phosphoric acid, and the adhesive resin Single Bond 2 and the resin composite Filtek Z350 were used to perform the restorations. The blocks were sectioned to obtain bar specimens. Each specimen group (enamel-E, dentin-D) was divided into four subgroups (n=15): S-artificial saliva; 10-10% CP bleaching; 15-15% CP bleaching; 20-20% CP bleaching. CP was applied for six hours daily for two weeks. The specimens were submitted to the a test in a universal testing machine. The data were analyzed by one-way ANOVA and the Tukey post-hoc test and a correlation analysis (r) was performed.Results: For Group E, the mean value (+/- standard-deviation) was 21.86 (+/- 6.03)a, 18.91 (+/- 8.31)ab, 15.43 (+/- 7.44)b and 10.6 (+/- 4.94)c for ES, E10, E15 and E20, respectively. For Group D, the alpha values were 34.73 (+/- 4.68)a, 35.12 (+/- 13.43)a, 29.67 (+/- 6.84)ab and 24.56 (+/- 6.54)b for DS, D10, D15 and D20, respectively. A negative correlation between the CP concentration and mean values was observed for both the enamel (r=-0.95) and dentin (r=-0.85) groups.Conclusion: In the current study, the bond strength of the restoration to enamel and the restoration to dentin were influenced by the application of CP and was dependent on the CP concentration in the bleaching gel.
Resumo:
Objective: This study evaluated the surface hardness of a resin cement (RelyX ARC) photoactivated through indirect composite resin (Cristobal) disks of different thicknesses using either a light- emitting diode (LED) or quartz tungsten halogen (QTH) light source. Material and Methods: Eighteen resin cement specimens were prepared and divided into 6 groups according to the type of curing unit and the thickness of resin disks interposed between the cement surface and light source. Three indentations (50 g for 15 s) were performed on the top and bottom surface of each specimen and a mean Vickers hardness number (VHN) was calculated for each specimen. The data were analyzed using two-way ANOVA and Tukey-Kramer test was used for post-hoc pairwise comparisons. Results: Increased indirect resin disk thickness resulted in decreased mean VHN values. Mean VHN values for the top surfaces of the resin cement specimens ranged from 23.2 to 46.1 (QTH) and 32.3 to 41.7 (LED). The LED curing light source produced higher hardness values compared to the QTH light source for 2- and 3-mm-thick indirect resin disks. The differences were clinically, but not statistically significant. Increased indirect resin disk thickness also resulted in decreased mean VHN values for the bottom surfaces of the resin cement: 5.8 to 19.1 (QTH) and 7.5 to 32.0 (LED). For the bottom surfaces, a statistically significant interaction was also found between the type of curing light source and the indirect resin disk thickness. Conclusions: Mean surface hardness values of resin cement specimens decreased with the increase of indirect resin disk thickness. The LED curing light source generally produced higher surface hardness values.