237 resultados para simulating


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Making heterolayered perovskite materials constitutes an approach for the creation of better dielectric and ferroelectric properties. In the experiment reported here, heterolayered PZT40/PZT60 films were grown on Pt/Ti/SiO2/Si (100) by a chemical solution deposition. The dielectric constant of the heterolayered thin film was significantly enhanced compared with that of pure PZT40 and PZT60 thin films. A dielectric constant of 701 at 100 kHz was observed for a stacking periodicity of six layers having a total thickness of 150 nm. The heterolayered film exhibited greater remanent polarization than PZT60 and PZT40 films. The values of remanent polarization were 7.9, 18.5, and 31 muC/cm(2), respectively, for pure PZT60, PZT40, and heterolayered thin films, suggesting that the superior dielectric and ferroelectric properties of the heterolayered thin film resulted from a cooperative interaction between the ferroelectric phases made from alternating tetragonal and rhombohedral phases of PZT, simulating the morphotropic phase boundary of this system. (C) 2004 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of the influence of motion and initial intra-articular pressure (IAP) on intra-articular pressure profiles in equine cadaver metatarsophalangeal (MTP) joints was undertaken as a prelude to in vivo studies, Eleven equine cadaver MTP joints were submitted to 2 motion frequencies of 5 and 10 cycles/min of flexion and extension, simulating the condition of lower and higher (double) rates of passive motion. These frequencies were applied and pressure profiles generated with initial normal intra-articular pressure (-5 mmHg) and subsequently 30 mmHg intra-articular pressure obtained by injection of previously harvested synovial fluid.The 4 trials performed were 1) normal IAP; 5 cyles/min; 2) normal IAP; 10 cycles/min; 3) IAP at 30 mmHg; 5 cycles/min and 4) IAP at 30 mmHg; 10 cycles/min. The range of joint motion applied (mean +/- s.e.) was 67.6 +/- 1.61 degrees with an excursion from 12.2 +/- 1.2 degrees in extension to 56.2 +/- 2.6 degrees in flexion, Mean pressure recorded in mmHg for the first and last min of each trial, respectively, were 1) -5.7 +/- 0.9 and -6.3 +/- 1.1; 2) -5.3 +/- 1.1 and -6.2 +/- 1.1; 3) 58.8 +/- 8.0 and 42.3 +/- 7.2; 4) 56.6 +/- 3.7 and 40.3 +/- 4.6. Statistical analyses showed a trend for difference between the values for the first and last minute in trial 3 (0.05>P<0.1) with P = 0.1 and significant difference (P = 0.02) between the mean IAP of the first and last min in trial 4. The loss of intra-articular pressure associated with time and motion was 10.5, 16.9, 28.1 and 28.9% for trials 1-4, respectively. As initial intraarticular pressure and motion increased, the percent loss of intra-articular pressure increased.The angle of lowest pressure was 12.2 +/- 1.2 (mean +/- s.e.) in extension in trials 1 and 2, In trials 3 and 4, the lowest pressures were obtained in flexion with the joints at 18.5 +/- 2.0 degrees (mean +/- s.e.). This demonstrated that the joint angle of least pressure changed as the initial intra-articular pressure changed and there would not be a single angle of least pressure for a given joint.The volume of synovial fluid recovered from the MTP joints in trial 3 compared to 4 (trials in which fluid was injected to attain IAP of 30 mmHg) was not significantly different, supporting a soft tissue compliance change as a cause for the significant loss of intra-articular pressure during the 15 min of trial 4.The pressure profiles generated correlate well with in vivo values and demonstrated consistent pressure profiles. Our conclusions are summarised as follows:1. Clinically normal equine MTP joints which were frozen and then later thawed were found to have mostly negative baseline intra-articular pressures, as would be expected in living subjects,2. Alternate pressure profiles of the dorsal and plantar pouch at baseline intra-articular pressure document the presence of pressure forces that would support 'back and forth' fluid movement between joint compartments. This should result in movement of joint fluid during motion, assisting in lubrication and nutrition of articular cartilage,3. If joint pressure was initially greater than normal (30 mmHg), as occurs in diseased equine MTP joints, joint motion further increased joint capsule relaxation (compliance) and, therefore, reduced intra-articular pressure.4. Peak intra-articular pressures reached extremely high values (often >100 mmHg) in flexion when initial pressure was 30 mmHg. Joint effusion pressures recorded for clinical MCP joints are frequently 30 mmHg. These IAP values are expected to produce intermittent synovial ischaemia in clinical cases during joint flexion.5, Additional in vivo studies are necessary to confirm our conclusions from this study and to identify the contributions of fluid absorption and the presence of ischaemia in a vascularised joint.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The photospheres of stars hosting planets have larger metallicity than stars lacking planets. This could be the result of a metallic star contamination produced by the bombarding of hydrogen-deficient solid bodies. In the present work we study the possibility of an earlier metal enrichment of the photospheres by means of impacting planetesimals during the first 20-30 Myr. Here we explore this contamination process by simulating the interactions of an inward migrating planet with a disc of planetesimal interior to its orbit. The results show the percentage of planetesimals that fall on the star. We identified the dependence of the planet's eccentricity (e(p)) and time-scale of migration (tau) on the rate of infalling planetesimals. For very fast migrations (tau= 10(2) and 10(3) yr) there is no capture in mean motion resonances, independently of the value of e(p). Then, due to the planet's migration the planetesimals suffer close approaches with the planet and more than 80 per cent of them are ejected from the system. For slow migrations (tau= 10(5)and 10(6) yr) the percentage of collisions with the planet decreases with the increase of the planet's eccentricity. For e(p) = 0 and 0.1 most of the planetesimals were captured in the 2:1 resonance and more than 65 per cent of them collided with the star. Whereas migration of a Jupiter mass planet to very short pericentric distances requires unrealistic high disc masses, these requirements are much smaller for smaller migrating planets. Our simulations for a slowly migrating 0.1 M-Jupiter planet, even demanding a possible primitive disc three times more massive than a primitive solar nebula, produces maximum [Fe/H] enrichments of the order of 0.18 dex. These calculations open possibilities to explain hot Jupiter exoplanet metallicities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, an analysis of the natural convection flow caused by heat sources dissipating energy at a constant rate simulating electronic components mounted at the bottom surface of a cavity symmetrically cooled from the sides and insulated at the top is performed. This problem was studied numerically and experimentally for several aspect ratios (height/width), for different levels of dissipation in the sources, and for different side wall temperatures. Temperature and velocity fields were determined as well as the temperature variation along the surface where the sources are mounted and the average Nusselt number in the source surfaces. Numerical and experimental results were found to agree.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated retention force and fatigue resistance of two overdenture attachment systems. Twenty samples (O-ring and Bar-Clip) from two manufacturers (Conexao Sistemas de Protese and Lifecore Biomedical) were prepared and divided into four groups: (i) Conexao/O-ring; (ii) Conexao/Bar-Clip; (iii) Lifecore/O-ring and (iv) Lifecore/Bar-Clip, with five samples in each group. They were submitted to mechanical fatigue test using a servohydraulic machine performing 5500 cycles of insertion and removal (f=0.8 Hz), immersed in artificial saliva. Retention force values were obtained three times (0, 3000 and after 5500 cycles) simulating the clinical service, using a tensile strength at 1 mm min(-1) and load cell of 1 kN. Data were analysed with analysis of variance and Tukey's test at 5% level. Results showed that Conexao/Bar-Clip specimens had significantly higher retention values than Lifecore/Bar-Clip (44.61 and 18.44 N, respectively), Conexao/O-ring specimens had significantly lower values than Lifecore/O-ring (13.91 and 19.75 N, respectively). Conexao/Bar-Clip values were always significantly higher than those of Conexao/O-ring group (44.61 and 13.91 N, respectively). Lifecore (O-ring and Bar-Clip) presented similar values (19.75 and 18.44 N, respectively). The systems evaluated showed satisfactory retention force values, before and after fatigue testing. Conexao/Bar-Clip specimens presented the highest values. A 5-year simulation of insertion and removal did not decrease retention values or fracture components.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The laser Welding process was introduced into dentistry by the end of the 1980s, resulting on a great impulse to that area with the development of cheaper and smaller equipment, using simpler technique. This allowed greater use of that process on the confection of prostheses compared to the brazing process since the heat source for that process is a concentrated light beam of high power, which minimizes distortion problems on the prosthetic pieces. Ag-Pd-Au-Cu alloy used on the confection of dental implant prostheses was observed before and after subjection to the laser welding process. The microstructure was analyzed with the. use of optic microscopy and the corrosion resistance was studied by the traditional electrochemical techniques and by electrochemical impedance, under environmental conditions simulating the aggressiveness found in the mouth cavity. A structural change was detected on the weld area, which presented a refined microstructure deriving from the high-speed cooling. The base metal out of the weld area presented a fusion coarse microstructure. The electrochemical essays showed differences on the potentiodynamic polarization behavior in both weld and metal base areas, indicating superior corrosion resistance in the weld area. The impedance spectra were characterized by capacitive distorted components, presenting linear impedance in the low frequencies area. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The disinfection of dental prostheses by immersion in a chemical solution should be capable of rapid inactivation of pathogenic microorganisms, without causing any adverse effect on the denture base resins. This study evaluated the effect of disinfection immersion on the transverse strength of two heat-cured resins. The denture base resins (Lucitone 550 and QC 20) were polymerized according to the manufacturers' instructions. After polymerization, the specimens were polished, and then stored in water at 37 degreesC for 50 +/- 2 h prior immersion in one of the following solutions for 10 min: 4% chlorhexidine, 1% sodium hypochlorite and 3.78% sodium perborate. The specimens were submitted to disinfection twice, simulating when dentures come from the patient and before being returned to the patient. Ten specimens were made for each group. The transverse strength was evaluated by a 3-point bend test. The flexural strength of the two denture base acrylic resins evaluated remained unaffected after immersion in the three solutions evaluated. In general, the QC 20 resin specimens exhibited lower transverse strength than the Lucitone 550 resin specimens, regardless of immersion solutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Making diagnoses in oral pathology are often difficult and confusing in dental practice, especially for the lessexperienced dental student. One of the most promising areas in bioinformatics is computer-aided diagnosis, where a computer system is capable of imitating human reasoning ability and provides diagnoses with an accuracy approaching that of expert professionals. This type of system could be an alternative tool for assisting dental students to overcome the difficulties of the oral pathology learning process. This could allow students to define variables and information, important to improving the decision-making performance. However, no current open data management system has been integrated with an artificial intelligence system in a user-friendly environment. Such a system could also be used as an education tool to help students perform diagnoses. The aim of the present study was to develop and test an open case-based decisionsupport system.Methods: An open decision-support system based on Bayes' theorem connected to a relational database was developed using the C++ programming language. The software was tested in the computerisation of a surgical pathology service and in simulating the diagnosis of 43 known cases of oral bone disease. The simulation was performed after the system was initially filled with data from 401 cases of oral bone disease.Results: the system allowed the authors to construct and to manage a pathology database, and to simulate diagnoses using the variables from the database.Conclusion: Combining a relational database and an open decision-support system in the same user-friendly environment proved effective in simulating diagnoses based on information from an updated database.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: the aim of this investigation was to evaluate the cervical adaptation of metal crowns under several conditions, namely (1) variations in the cervical finish line of the preparation, (2) application of internal relief inside the crowns, and (3) cementation using different luting materials. Method and Materials: One hundred eighty stainless-steel master dies were prepared simulating full crown preparations: 60 in chamfer (CH), 60 in 135-degree shoulder (OB), and 60 in rounded shoulder (OR). The finish lines were machined at approximate dimensions of a molar tooth preparation (height: 5.5 mm; cervical diameter: 8 mm; occlusal diameter: 6.4 mm; taper degree: 6; and cervical finish line width: 0.8 mm). One hundred eighty corresponding copings with the same finish lines were fabricated. A 30-mu m internal relief was machined 0.5 mm above the cervical finish line in 90 of these copings. The fit of the die and the coping was measured from all specimens (L0) prior to cementation using an optical microscope. After manipulation of the 3 types of cements (zinc phosphate, glass-ionomer, and resin cement), the coping was luted on the corresponding standard master die under 5-kgf loading for 4 minutes. Vertical discrepancy was again measured (L1), and the difference between L1 and L0 indicated the cervical adaptation. Results: Significant influence of the finish line, cement type, and internal relief was observed on the cervical adaptation (P < .001). The CH type of cervical finish line resulted in the best cervical adaptation of the metal crowns regardless of the cement type either with or without internal relief (36.6 +/- 3 to 100.8 +/- 4 mu m) (3-way analysis of variance and Tukey's test, alpha = .05). The use of glass-ionomer cement resulted in the least cervical discrepancy (36.6 +/- 3 to 115 +/- 4 mu m) than those of other cements (45.2 +/- 4 to 130.3 +/- 2 mu m) in all conditions. Conclusion: the best cervical adaptation was achieved with the chamfer type of finish line. The internal relief improved the marginal adaptation significantly, and the glass-ionomer cement led to the best cervical adaptation, followed by zinc phosphate and resin cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Injection metering systems are an important option for the development of pesticide application equipment, with advantages relating to minimising the need for disposal of unused pesticide, improving the ease of cleaning and optimising the accuracy of chemical application. For all injection systems, characteristics such as the steady-state accuracy of delivered dose, dose stability and the time response for dose step changes are related to the ability of the system to operate with different chemical formulations. A system designed to inject liquids should be able to accommodate changes in viscosity and density. The aim of this study was to develop a methodology for testing chemical injection systems using liquids with different viscosities. The experimental arrangement simulating applications with injection metering systems used dye and salt solutions as tracers. Tests were conducted to analyse the influence of salt on the characteristics of the water and a viscous solution. Results showed that the salt interfered with the dye stability in the water solution. In tests with a viscous test liquid, the salt was introduced at different steps during the mixing process, providing four different liquids to be analysed in terms of viscosity, density and pH. Some differences in liquid characteristics were found which could influence the performance of the injection systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When the carious tissue is eliminated either by conventional methods (with burs) or with lasers, the risk of accidentally damage the surface of adjacent teeth may occur, which hypothetically could lead to a more susceptible surface for canes formation. This in vitro study aims to evaluate the caries resistance of the dental enamel surface irradiated by the Nd:YAG laser applied in conditions simulating accidental exposition. Thirteen third molars were used in this study. The experimental groups were: G1: sound control and control + carious; G2: contact Nd:YAG laser at 0.75, 1, 2, or 3 W; 10 Hz; 3 sec (27, 35, 71, and 106 J/cm(2)); G3: same parameters from G2 + caries artificial induction through the demineralization and demineralization (DES/RE) dynamic model. The caries resistance analysis was evaluated by the superficial morphological aspect through SEM images and also by Ca/P proportion through energy dispersive X-ray spectroscopy (EDX). The micrograph images showed that the Nd:YAG laser changed the normalmorphology of the enamel prisms resulting in a melted and re-solidified surface intensified with the power increase. Significant statistical differences were observed applying the Kruskal-Wallis statistical test (p <= 0.01) among the Nd:YAG laser irradiated groups and the control with caries regarding the Ca/P proportion. As an exception, this was not observed when 3 W; 10 Hz; 3 sec; 106 J/cm(2) was applied and posteriously submitted to a cariogenic challenge. The results indicate that the Nd:YAG laser accidental irradiation at low power settings did not represent risks to the enamel caries resistance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Heat recovery devices are important in the optimization of thermal systems, since they can be used to reduce thermal losses to the environment. The use of heat pipes in these types of equipment can provide heat recoveries of higher efficiency, since both fluid flows are external and there are less contamination risks between the hot and cold fluids. The objective of this work is to study a heat recovery unit constructed with heat pipes and mainly, to analyze the influence of the inclination of the heat pipes on the performance of the equipment. For this analysis, a heat recovery unit was constructed which possesses 48 finned heat pipes in triangular geometry, the evaporator and condenser being of the same length. This unit was tested in an air-air system simulating a heat recovery process in which heat was supplied to the hot fluid by electrical resistances. The results have shown that there exists an inclination at which the system has a better performance, but for higher inclinations there is no significant increase of the efficiency of the system. This paper also presents the influence of inclination of heat pipes on effectiveness and NTU parameters which are important in heat exchanger design.