96 resultados para prosthesis fit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein is reported the case of a patient who presented initially with aortic insufficiency and a fistula between the sinus of Valsalva and right atrium when aged 31 years. Closure of the fistula and replacement of the aortic valve with a Starr-Edwards A-9 caged-ball prosthesis was performed in 1972, since when the valve has survived for 40 years without dysfunction. This is one of the longest follow ups of the Starr-Edwards prosthesis reported, and highlights the possibility of acceptable valve performance over long periods of time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this article is to describe a successful clinical protocol for prosthodontic rehabilitation of a patient with a skeletal Class III malocclusion using a fixed-detachable maxillary prosthesis supported by 6 implants and the MK1 attachment system. The patient was followed up for 8 years. A 46-year-old edentulous woman with a skeletal Class III malocclusion expressed dissatisfaction with her old existing maxillary denture from an esthetic point of view and frustration regarding its function. A fixed-detachable maxillary prosthesis using the MK1 attachment system was made. The patient was followed up clinically and radiographically for 8 years. No bone loss, fracture of prosthetic components, or fracture of the prosthesis was detected in that period. A fixed detachable maxillary prosthesis using the MK1 attachment system is a treatment option for patients with Class III malocclusions who opt not to undergo orthognathic surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Amputations affect both the physical and the psychological aspects of an individual, causing significant impact on self-esteem. The main causes of finger amputations are work-related accidents with dangerous machinery, road traffic accidents, and animal bites, as well as systemic diseases such as diabetes. This report aims to describe a simple technique for fabrication of implant-retained finger prosthesis with a modified base of the retention system.Case Description and Methods: The O-Ring retention system was used with a modified hexagon-shaped base and a metallic capsule adapted to the acrylic resin to attach the prosthesis to the implant.Findings and Outcomes: The prosthesis was made with silicone, and after osseointegration, it was installed without complications, leading to a patient satisfied with the end result and encouraged to return to social life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the main reasons for the failure in dental implant treatments is the overload, which can cause bone resorption and later, the osseointegration loss in the implant. Therefore, the aim of this study was to analyze the tension generated around dental implants in the rehabilitation of three mandible posterior teeth, varying the connection type, the disposal, and the quantity of implants. The photoelasticity method was used in order to accomplish it. Through photoelasticity, the quantity and localization of the tensions around the implants in the different studied groups were compared (three straight line implants, three offset placement implants, two implants with a mesial cantilever, and two implants with a pontic). The results showed that the tension quantity and disposition around the dental implants of the connection external hexagon and internal hexagon were similar in all groups. In the group where the cantilever was used, an increase of the tension around the implant, adjacent to the cantilever, was observed. From the results it is concluded that the type of connection used in this study did not influence the tension quantity and distribution around the implants; however, the prosthetic configuration with the cantilever use, led to an increase of the tension around the implant, adjacent to the cantilever.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The aim of this report is to describe a quick and simple method of positioning retention magnets when deformed patients are rehabilitated with an oculopalpebral prostheses attached to a maxillary denture/obturator. Background: In patients with deformities requiring complex rehabilitations, the use of magnets is the most efficient means of providing combined prostheses with retention quality and stability. Usually prostheses with magnets are in sections and have a magnet in each section. When the sections are put together properly, the magnets are attracted to each other and retain the sections. Report: An edentulous patient presented for a post-surgical evaluation of a maxillofacial prosthesis used to repair a partial maxillectomy and left orbital exoneration which removed all adjacent tissues leaving an open communication between the oral, nasal, and orbital cavities. The proposed treatment plan included construction of a maxillary complete denture with a palatal obturator and a mandibular complete denture. Magnets were used to attach the oculopalpebral prosthesis to the maxillary denture/obturator. Summary: Use of retention magnets simplify the clinical and laboratorial phase, retains the denture, and makes it stable and comfortable for the patient. This treatment is one successful approach to the restoration of oral function and increases the patient’s quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here, we present a case report on prosthetic reconstruction of posterior teeth and composite resin restoration of anterior teeth yielding considerable esthetic improvement, reestablishment of disocclusion guides and function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hand deformities affect aesthetics function of hand severely compromised and also cause psychological disturbances. This report describes the fabrication of a silicone finger prosthesis for a patient after an accident at work. The finger prosthesis was retained by a vacuum effect on the stump. The silicone material Silastic-MDX 44210 was used to provide function and aesthetics. The finger prosthesis offered psychological, functional and rehabilitative advantages for the patient. Restoring the natural appearance with the prosthesis eliminated the trauma generated by the dysfunction and represented an efficient psychological therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of modern odontology is to reconstitute to the patient the comfort, the function, the aesthetic form, the phonetic capability, and normal health. However, the more the patient is toothless, the more this objective becomes difficult inside traditional dentistry. As a result of continuous research of materials and techniques, permissible success is now a reality, whitewashing many challenging clinical situations. Thus, the objective of the article was to present a clinical case where association of the universal cast to long abutment pillars and EsthetiCone were used for aesthetic whitewashing. A man presented to the clinic of the Faculty of Dentistry, Universidade Estadual Paulista. After clinical examination and radiographic evaluation evidenced the necessity of substitution of fixed prostheses (15-25), he was presented with disadaptation and a favorable aesthetic solution. Ahead of the evaluated picture and considering the extension of the toothless space made, it was opted more, to the accomplishment of surgery, the setting of 2 implantations in the region and 2 in each edentate side of the posterior portion of the jaw. On 6 implants and 2 teeth, 10 metal ceramic crowns had been confectioned: 4 of them being joined in the region of the 12 to the 22 and the other 6 as unit crowns in the region of the 13, the 14, the 15, the 23, the 24, and the 25. The carried-through treatment was capable to return the aesthetic form, the function, the phonetic capability, the comfort, and the health of the verbal socket.