334 resultados para prótese intraocular


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work it was studied the behavior of four water bath curing cycles of heat activated acrylic resin considered as long duration (I – 65ºC for 30 min;50ºC for 23h and 30min; and 100º C for 1h; II- 50ºC for 24h and the rapid cycle), compared to the known long time curing cycle (9 hours for 72ºC) and short curing cycle (1 h for 65ºC; 30 min to elevate at 100º C and 1:00 to 100º C). Analysis consisted of observations and verification of the residual monomer, weight alterations, dimensional, dimensional lineal, porosity and hardness to determine material performance. The results pointed out that residual monomer presented statistical significant differences in the factor storage and interaction among the factors cycle X storage for weight alteration; statistical significant differences for the factor storage for lineal dimensional alterations, without significant differences for hardness. Porosity was verified in minimum degree in the cycle III and in appreciable amount in the cycle IV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To determine the effects of the administration of subconjunctival 1% atropine (SA), topical 1% atropine (A), 0.5% tropicamide (T), 1% homatropine (H), 10% phenylephrine (P), and 2% ibopamine (I) on intraocular pressure (IOP), pupil diameter (PD), ruminal motility (RM) and intestinal motility (IM) in sheep.Animal studied Ten spayed ewes of Santa Ines breed.Procedures Six experiments were performed separately at 1-week intervals. One eye was randomly selected and received one drop of A, T, H, P, I, or subconjunctival injection of atropine at 8 a. m. On the following days, IOP and PD were evaluated every 8 h until the pupil returned to its normal diameter. Ruminal motility and intestinal motility were evaluated only within the first 13 h.Results The IOP did not change significantly in the treated eyes compared with the control eyes and baseline at any time point (P > 0.05). A longer-lasting pupil dilation was observed after the administration of A (96 h), SA (79 h), H (24 h), and T (24 h). Within the first 30 min after treatment, RM and IM decreased, by 78% and 82% (H), 76% and 86% (SA), 46% and 58% (A), and 62% and 70% (T) (P < 0.001), respectively, with a tendency to return to baseline values following 13 h of drug administration. Both 10% phenylephrine and 2% ibopamine did not have any effect on the parameters evaluated (P > 0.05).Conclusions Topical and subconjunctival 1% atropine, 0.5% tropicamide, and 1% homatropine significantly reduced RM and IM, and induced pupil dilation but did not change IOP in eyes of healthy sheep. The sympathomimetics phenylephrine (10%) and ibopamine (2%) did not change the parameters evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was evaluate the effects of three anesthetic combinations, ketamine-midazolam, ketamine-xylazine and tiletamine-zolazepam, on IOP in rabbits. In a experimental, blind, randomized, crossover study, six rabbits were anesthetized with each of 3 treatments in random order. Groups KM (ketamine, 30 mg/kg + midazolam, 1 mg/kg); KX (ketamine, 30 mg/kg + xylazine, 3 mg/kg); and TZ (tiletamine + zolazepam, 20 mg/kg). The drugs were mixed in the same syringe injected intramuscularly (IM) into the quadriceps muscle. IOP was measured before drug administration (baseline) and at 5-minute intervals for 30 minutes. The data were analyzed by a 2-way repeated measures ANOVA followed by Bonferroni test. All groups had significant decreases in IOP compared to baseline (p < 0.001). There was no difference between groups at any of the time points assessed (p > 0.05). Administration of either ketamine-midazolam, ketamine-xylazine, or tiletamine-zolazepam similarly decrease IOP in rabbits within 30 minutes of injection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a case report with the use of short dental implants and immediate prosthesis placement. After 13 months of follow-up, peri-implant probing values are near 1.87 mm and ISQ values around 78.56.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The success rate of resin-bonded fixed partial dentures is directly related to the adhesive system and the tooth preparation design for good retention. These resin-bonded bridges represent a prosthodontic alternative, based on their costeffectiveness, conservative techniques, and ease of laboratory manufacturing. Through a thorough review of the literature, this study aimed to report on cavity designs, types of materials used, and the advantages and disadvantages of the resin-bonded fixed partial denture. One of significant advantages of the resin-bonded fixed partial dentures is the conservation of the tooth structure, whereas its main disadvantage includes aesthetic limitations, given that the alloy may in fact be visible. Preparation design, cement type, and casting alloy type, as well as surface treatment, are among the factors that influence the longevity of resin-bonded fixed partial dentures. Treatments with resin-bonded fixed partial dentures present a bright outlook regarding the conservation of tooth structures, as well as a high level of success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of different methods and materials should be considered during the planning of implant-supported prostheses. Complications such as fractures of the acrylic resin base, wear and fracture of teeth can occur frequently, creating the need for careful planning for each patient, which can make the selection of the type of treatment more complex. Thus, this article describes the oral rehabilitation of a completely edentulous patient with bimaxillary fixed implant-supported prosthesis, with complaints on aesthetics, loss of vertical dimension and fracture of acrylic resin teeth of the upper arch. After the restoration of vertical dimension, his dentures were replaced with new bimaxillary implant-supported fixed prostheses, ceramic and acrylic resin were used as veneering material for maxilla and mandible, respectively. At the end of the treatment, the patient received bimaxillary flat occlusal splints to protect the teeth and implants of possible parafunctional habits. The approach for the treatment allowed a quick and effective resolution, with aesthetic and functional outcomes very favorable for the patient.