94 resultados para occlusal loads
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Background: The purpose of this study is to analyze the tension distribution on bone tissue around implants with different angulations (0 degrees, 17 degrees, and 30 degrees) and connections (external hexagon and tapered) through the use of three-dimensional finite element and statistical analyses.Methods: Twelve different configurations of three-dimensional finite element models, including three inclinations of the implants (0 degrees, 17 degrees, and 30 degrees), two connections (an external hexagon and a tapered), and two load applications (axial and oblique), were simulated. The maximum principal stress values for cortical bone were measured at the mesial, distal, buccal, and lingual regions around the implant for each analyzed situation, totaling 48 groups. Loads of 200 and 100 N were applied at the occlusal surface in the axial and oblique directions, respectively. Maximum principal stress values were measured at the bone crest and statistically analyzed using analysis of variance. Stress patterns in the bone tissue around the implant were analyzed qualitatively.Results: The results demonstrated that under the oblique loading process, the external hexagon connection showed significantly higher stress concentrations in the bone tissue (P < 0.05) compared with the tapered connection. Moreover, the buccal and mesial regions of the cortical bone concentrated significantly higher stress (P < 0.005) to the external hexagon implant type. Under the oblique loading direction, the increased external hexagon implant angulation induced a significantly higher stress concentration (P = 0.045).Conclusions: The study results show that: 1) the oblique load was more damaging to bone tissue, mainly when associated with external hexagon implants; and 2) there was a higher stress concentration on the buccal region in comparison to all other regions under oblique load.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
To evaluate the influence of examiner's clinical experience on detection and treatment decision of caries lesions in primary molars. Design Three experienced dentists (Group A) and three undergraduate students (Group B) used the International Caries Detection and Assessment System (ICDAS) criteria and bitewing radiographs (BW) to perform examinations twice in 77 primary molars that presented a sound or carious occlusal surface. For the treatment decision (TD), the examiners attributed scores, analyzing the teeth in conjunction with the radiographs. The presence and the depth of lesion were validated histologically, and reproducibility was evaluated. The sensitivity, specificity, accuracy, and area under the ROC curve values were calculated for ICDAS and BW. The associations between ICDAS, BW, and TD were analyzed by means of contingency tables. Results Interexaminer agreement for ICDAS, BW, and TD were excellent for Group B and moderate for Group A. The two groups presented similar and satisfactory performance for caries lesion detection using ICDAS and BW. In the treatment decision, Group A was shown to have a less invasive approach than Group B. Conclusion The examiner's experience was not determinant for the clinical and radiographic detection of occlusal lesions in primary teeth but influenced the treatment decision of initial lesions.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES
Resumo:
Immediate functioning of osseointegrated implants has been widely employed in edentulous patients due to its safety and high predictability. However, viability and success of immediate-loaded implants is defined by factors such as number of implants, distribution and splinting, as well as reduction of oblique loads and excessive occlusal contacts. The indirect composite resin-modified glass enable building of a highly aesthetic prosthesis, combining satisfactory resistance and better force dissipation on occlusal loading. This article describes a resin composite, mandibular fixed prosthesis on osseointegrated implants in immediate function.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.
Resumo:
The aim of the present study was to evaluate the effect of the use of an occlusal splint in children with bruxism in a pilot study with a short-term follow up. Seventeen children were recruited, only nine of whom formed the sample following the application of the inclusion criteria: presence of sleep bruxism for at least six months (based on parents' reports); presence of at least the first permanent molars; and no previous history of treatment involving an occlusal splint. The sample was submitted to a clinical exam. Other sleep problems were screened with the use of a sleep questionnaire filled out by parents before and after 90 days of occlusal splint usage. The children received a flat acrylic resin splint with full coverage of the occlusal surfaces to be worn in the maxilla. In children with erupting teeth, a space was created in the splint to allow normal eruption. After the 90-day period, the absence of sleep bruxism and sleep movements was noted in most of children. Moreover, snoring was reduced in nearly 50%, which raises a new issue to be investigated with regard to the pathophysiology of sleep bruxism. The use of an occlusal splint was effective in reducing the symptoms of sleep bruxism and other sleep problems. Further investigations should be carried out on the relationship between snoring and sleep bruxism in children.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and oblique (45 degrees) loads were applied in the occlusal surface of the crowns by using a universal testing machine (EMIC). The stresses were photographically recorded and qualitatively analyzed using a software (Adobe Photoshop). Under axial loading, the number of fringes was inversely proportional to the diameter of the implants in the single crown models. In the splinted 3-unit piece, the 3.75-mm implant promoted lower number of fringes regardless of loading area application. Under oblique loading, a slight increase of fringes number was observed for all groups. The standard implant diameter promoted better stress distribution than the narrow and mini diameter implants. Additionally, the splinted crowns showed a more uniform stress distribution.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)