95 resultados para jaws
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Biopatologia Bucal - ICT
Resumo:
Introduction: The radiographic characteristics of a biomaterial, such as its density, may influence the evaluation of the results obtained following its clinical use. Objective: The aim of this study was to evaluate the radiographic density of biomaterials used as bone substitutes, inserted into dental sockets and bone defects in created in the jaws of pigs. The influence of a soft tissue simulator on the results was also evaluated. Material and method: Two and three-millimeter-deep bone defects were created in the pigs mandible and the right first molar extraction socket were used. Commercial samples of five biomaterials were tested: Hydroxyapatite, Lyophilized Bovine Bone, 45S5 bioglass (generic), PerioGlass and β-Tri-Calcium Phosphate, and compared to a positive (mandibular bone) and negative (empty alveolar bone defects) controls. Radiographic images were acquired with and without a 10 mm thick soft-tissue simulator. Result: The results for the extraction sockets showed no differences between the biomaterials and the negative control. For the bone defects, the depth of the defect density influenced the density, both in the negative control (p < 0.01) and biomaterials (p < 0.05) groups. The soft- tissue simulator did not alter the results. Conclusion: The type of the evaluated defect can interfere in the radiographic features presented by each biomaterial, while the simulation of soft tissues was not statistically significant.
Resumo:
The rehabilitation of edentulous areas with osseointegrated dental implants is a well-documented, predictable procedure in the literature, with high success rates. However, the lack of bone at the recipient bed or proximity to anatomic structures limits the rehabilitation procedure especially at the posterior mandible. Thus, short implants are an alternative treatment for such cases of severe bone resorption. The purpose of this study was to review the success rate of short implants, especially those based in the posterior mandible and to show a clinical case. A literature review was made on electronic databases PubMed and Bireme with articles published between the years 2005 to 2012, using the keywords "short dental implants". It was concluded that the success rates of short implants are similar to those presented by conventional implants but still related to their geometry and surface treatment. Also, short implants can be considered as a viable alternative for the rehabilitation of severely resorbed jaws. However, many authors consider that more research is necessary when a short implant is compared to a long dental implant.
Resumo:
Jaws atrophy represents a great challenge to Implantology regarding rehabilitation of edentulous areas. This paper reports an extreme mandibular atrophy with only 9mm of height between the mental foramina. In these situations, treatment options include bone augmentation techniques, transmandibular, or short dental implants. It is well accepted that bone grafts to improve height do not have good predictability. Besides, osteogenic distraction is associated with a great patient discomfort and transmandibular implants are related with high failure rates. Also, surgical-prosthetic rehabilitations with short dental implants had been associated to good success rates. The purpose of this clinical case is to report a severe mandibular atrophy, successfully treated with four short dental implants between mental foramina for implant-supported prosthesis.
Resumo:
The use of different methods and materials should be considered during the planning of implant-supported prostheses. Complications such as fractures of the acrylic resin base, wear and fracture of teeth can occur frequently, creating the need for careful planning for each patient, which can make the selection of the type of treatment more complex. Thus, this article describes the oral rehabilitation of a completely edentulous patient with bimaxillary fixed implant-supported prosthesis, with complaints on aesthetics, loss of vertical dimension and fracture of acrylic resin teeth of the upper arch. After the restoration of vertical dimension, his dentures were replaced with new bimaxillary implant-supported fixed prostheses, ceramic and acrylic resin were used as veneering material for maxilla and mandible, respectively. At the end of the treatment, the patient received bimaxillary flat occlusal splints to protect the teeth and implants of possible parafunctional habits. The approach for the treatment allowed a quick and effective resolution, with aesthetic and functional outcomes very favorable for the patient.
Resumo:
The contemporary implant dentistry is in constant technological development, improving the oral rehabilitation process of partial or totally edentulous patients. On the other hand, anatomical limitations, such as the maxillary sinus and the mandibular canal in the posterior region of the jaws can limit the implant placement. Furthermore, due to the absence of dental elements, alveolar ridge atrophy is frequently observed. This aspect represents a loss either in quantity or quality of the bone tissue available for the dental implant rehabilitation. To make possible the dental implant rehabilitation even in adverse conditions, some solutions have been considered, such as the use of short implants (≤ 10 mm length) and/or small diameter implants (2,8; 3,3 and 3,5 mm width). The aim of this study is to present a literature review considering the use of short implants in oral rehabilitation, presenting the currently view of the matter. Based on the literature review, the use of short implants produced similar clinical success to conventional implants (greater than 10 mm in length). Therefore, its use can be considered a viable alternative, where anatomical limitations are present.
Resumo:
Purpose: Trying to provide more anatomical data to the oral and maxillofacial surgeons regarding to orthognathic surgery, specifically about sagittal split osteotomy, the authors accomplished an anatomical study in dry human jaws, measuring the thickness in four previously established points of the body and mandibular ramus, at the usual spots used for the internal fixation by screws. Material and Methods: The authors also use the data collected to evaluate if there are significant differences between the group I (human dry mandibles with teeth) and group II (edentulous human dry mandibles). Results: For the group I the authors found the following results: x1 = 14,48, x2 = 14,94, x3=12,82 and x4 = 9,41, being the x2 the thickest point, and the least thick the x4. However in the group II, the found medium values were: x1 = 13,38, x2 = 13,08, x3 = 11,63 and x4 = 12,18, being the thickest point in that group the x1 and the least thick x3. The coefficient of simple correlation between the variables (group I and II) revealed a value of 0,6194, being this difference no significant at the meaning level of 95%.
Resumo:
Purpose: The authors tried to verify the anatomic location of the mandibular foramen and língula in dry jaws regarding the anterior and posterior border of the mandible and the incisure, alveolar border and mandibular base, in order to correlate the data with the sagittal split ramus osteotomy. Methods: There were evaluated 44 mandibles (88 sides) from the Morphology Department of the Araraquara Dental School of the São Paulo University (UNESP). The distances measured were previously deter - mined according to the figures presented in this article and were done by the use of a sliding caliper (Brow & Sharpe Digit-Cal Plus), with the mandibles positioned over a Erickson table, and the distan - ces were always measured in millimeters. Results: The pre-determined points and distances founded were X=17,67; Y=14,35; W=20,96 and Z=21,89 for the mandibular foramen, and the relationship between this anatomical structure and the língula shows that the mandibular foramen is in average 5,82 mm below the língula. Conclusions: The authors conclude that the mandibular foramen is lightly posterior in comparison with the ramus mandibular center and that the língula is a very important anatomic landmark for the ramus surgeries as well the knowledge of the distance between it and the mandibular foramen entrance.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Florid cemento-osseous dysplasia (FCOD) is a non-neoplastic condition of the jaws that is not associated with inflammation of the pulp or periodontal tissue. This article reports on three cases that were diagnosed as FCOD, demonstrating the importance of both clinical and radiographic diagnosis and the clinical management of these lesions.
Resumo:
Cherubism is a congenital childhood disease of autosomal dominant inheritance. This disease is characterized by painless bilateral enlargement of the jaws, in which bone is replaced with fibrous tissue. The condition has sui generis clinical, radiographic and histological features, of which the clinician should be aware for a better differential diagnosis in the presence of a fibro-osseous lesion affecting the bones of the maxillomandibular complex. The purpose of present paper was to review the literature and to report the most important aspects of cherubism in order to facilitate the study of this disease. Literature was reviewed about cherubism, emphasizing the relevant clinicoradiographic features and treatment. Literature was selected through a search of PubMed and Scielo electronic databases. The keywords used for search were adolescent, cherubism, cherubism/physiopathology, cherubism/treatment, cherubism/radiography. A manual search of the reference lists of the identified articles and the authors' article files and recent reviews was conducted to identify additional publications. Those studies that described new features about cherubism were included in this review. In total 44 literature sources were obtained and reviewed. Studies that described new features about cherubism physiopathology, diagnostics and treatment were reviewed. Despite the exceptions, cherubism is a clinically well-characterized disease. In cases of a suspicion of cherubism, radiographic examination is essential since the clinical presentation, the location and distribution of the lesions may define the diagnosis. Histopathological examination is complementary. Nowadays, genetic tests should be used for final diagnosis of cherubism.
Resumo:
Cherubism is a rare autosomal-dominant inherited syndrome and is usually self-limiting; it starts in early childhood and involutes by puberty. It is a benign fibroosseous disease, characterized by excessive bone degradation of the upper and lower jaws followed by development of fibrous tissue masses. The purpose of this clinical report is to describe a rare and aggressive form of cherubism on an adult female patient that has been treated in our Bioscience Center for Special Health Care Needs-CEBAPE. The patient was firstly submitted to the surgical procedure with partial curettage of the lesion, and the cavity was filled with autogenous cancellous bone and bone marrow grafts. Furthermore, the support treatment used was the administration of salmon calcitonin by nasal spray during the first year after the preconized procedure. At 4-year followup, we confirmed the stomatognathic system improvement and esthetic rehabilitation, which led to a significant increase in the patient's quality of life.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)