125 resultados para irradiation capsules


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To establish safety parameters, we in vitro studied the increase in intrapulpal temperature caused by the use of a cw CO2 laser. A thermistor was implanted in the inner part of the pulpal chamber of 25 human lower third molars to measure the intrapulpal temperature produced by laser powers between 2-10 W and exposure times of 0.5-25.0 s. The Pearson linear correlation factor applied to the measured values showed there is a direct relationship between the independent variable and the applied power. A variance analysis produced the linear regression equation: T=1.10+(0.127)E where T is the temperature and E the energy. The results showed that, with a power of 4 W and maximum exposure time of 2.5 s (10 J) and a power density of 12738.85 W cm-2, there will be no damaging reactions affecting the pulpal tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface morphology changes induced by argon laser irradiation (514 nm) on disperse red 13 (DR13) films prepared by physical vapor deposition (PVD) were investigated. Atomic force microscopy was used to characterize the irradiated sample for different periods of irradiation. Needle-shape structures are observed which are attributed to the symmetry of DR13 molecules. The film becomes increasingly closely packed with the irradiation, with lower root mean square roughness for long exposure times. This is due to photoisomerization of DR13 molecules and probably heating of the sample, which can provide the required mobility for the molecular rearrangement. The rearrangement is such that voids in the film are filled in upon irradiating the sample, thus decreasing the film roughness and increasing the packing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of He-Ne laser radiation on the formation of new blood vessels in the bone marrow compartment of a regenerating area of the mid-cortical diaphysis of the tibiae of young adult rats was studied. A small hole was surgically made with a dentistry burr in the tibia and the injured area received a daily laser therapy over 7 or 14 days transcutaneously starting 24 h from surgery. Incident energy density dosages of 31.5 and 94.5 Jcm-2 were applied during the period of the tibia wound healing investigated. Light microscopic examination of histological sections of the injured area and quantification of the newly-formed blood vessels were undertaken. Low-level energy treatment accelerated the deposition of bone matrix and histological characteristics compatible with an active recovery of the injured tissue. He-Ne laser therapy significantly increased the number of blood vessels after 7 days irradiation at an energy density of 94.5 Jcm-2, but significantly decreased the number of vessels in the 14-day irradiated tibiae, independent of the dosage. These effects were attributed to laser treatment, since no significant increase in blood vessel number was detected between 8 and 15 non-irradiated control tibiae. Molecular mechanisms involved in low-level laser therapy of angiogenesis in post-traumatic bone regeneration needs further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this investigation was to evaluate the cleaning effect of CO 2 on surface topography and composition of failed dental implant surfaces. Ten failed dental implants were retrieved from nine patients (mean age, 46.33 ± 5.81 years) as a result of early or late failure. The implants were divided into two parts: one side of the implant was irradiated with a CO 2 laser (test side), while the other side did not receive irradiation (control side). The CO 2 laser was operated at 1.2 W in a continuous wave for 40 seconds (40 J energy). The handpiece of the CO 2 laser was kept at a distance of 30 mm from the implant surface, resulting in a spot area of 0.031415 cm 2 (38.20 W/cm 2; 1559 J/cm 2) in scanning mode (cervical-apical). One unused dental implant was used as a negative control for both groups. All implant surfaces were examined by scanning electron mi croscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) for element analysis. SEM showed that the surface of the test sides consisted of different degrees of organic residues, appearing mainly as dark stains similar to those observed on the control sides. None of the test surfaces presented alterations such as crater-like alterations, lava-like layers, or melting compared with the nonirradiated surfaces. Foreign elements such as carbon, oxygen, sodium, calcium, and aluminum were detected on both sides. These results suggest that CO 2 laser irradiation does not modify the implant surface, although the cleaning effect was not satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of water bath and microwave postpolymerization treatments on the cytotoxicity of 6 hard reline acrylic resins. Materials and Methods: The materials tested were Tokuso Rebase Fast (TR), Ufi Gel Hard (UGH), Duraliner II (D), Kooliner (K), New Truliner (NT), and Light Liner (LL). LL resin was additionally tested with an air-barrier coating (LLABC). Nine disks of each material (10 × 1 mm) were made and divided into 3 groups: group 1 (no postpolymerization treatment); group 2 (postpolymerization in microwave oven); group 3 (postpolymerization in water bath at 55°C for 10 minutes). L929 cells were cultured in 96-well plates and incubated for 24 hours in Eagle's medium. Eluates prepared from the disks or medium without disks (control) replaced the medium. Cytotoxicity was assessed by both dehydrogenase succinic activity (MTT) assay and incorporation of radioactive 3H-thymidine assay. Tests were carried out in quadruplicate and repeated twice. Differences between groups were determined by analysis of variance with Tukey multiple-comparison intervals (α = .05). Results: For MTT assay, the postpolymerization treatments had no effect on the cytotoxicity of all materials (P > .05). For 3H-thymidine assay, the postpolymerization treatments significantly decreased the cytotoxicity of UGH (P < .05). The cytotoxicity of K, NT, LL, and LLABC increased after microwave irradiation (P < .05). TR, NT, and LLABC showed an increase in cytotoxicity after water bath (P < .05). Conclusion: When assessed by MTT assay, the cytotoxicity of the materials was not affected by postpolymerization treatments. 3H-Thymidine assay showed that the cytotoxicity of the resins was not improved by the postpolymerization treatments, with the exception of UGH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the effectiveness of microwave irradiation on the disinfection of simulated complete dentures. Materials and Methods: Eighty dentures were fabricated in a standardized procedure and subjected to ethylene oxide sterilization. The dentures were individually inoculated (10 7 cfu/mL) with tryptic soy broth (TSB) media containing one of the tested microorganisms (Candida albicans, Streptoccus aureus, Bacillus subtilis, and Pseudomonas aeruginosa). After 48 hours of incubation at 37°C, 40 dentures were individually immersed in 200 mL of water and submitted to microwave irradiation at 650 W for 6 minutes. Forty nonirradiated dentures were used as positive controls. Replicate aliquots (25 μL) of suspensions were plated at dilutions of 10 -3 to 10 -6 on plates of selective media appropriate for each organism. All plates were incubated at 37°C for 48 hours. TSB beakers with the microwaved dentures were incubated at 37°C for 7 more days. After incubation, the number of colony-forming units was counted and the data were statistically analyzed by Kruskal-Wallis test (α = .05). Results: No evidence of growth was observed at 48 hours for S aureus, B subtilis, and C albicans. Dentures contaminated with P aeruginosa showed small growth on 2 plates. After 7 days incubation at 37°C, no growth was visible in the TSB beakers of S aureus and C albicans. Turbidity was observed in 3 broth beakers, 2 from P aeruginosa and 1 from B subtilis. Conclusion: Microwave irradiation for 6 minutes at 650 W produced sterilization of complete dentures contaminated with S aureus and C albicans and disinfection of those contaminated with P aeruginosa and B subtilis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In indicating the microwave irradiation for disinfecting dentures it is necessary to see how this procedure influences Candida albicans integrity and viability. The aim of this study was to evaluate the ability of microwaves to inactivate C. albicans and damage cell membrane integrity. Two 200-ml C. albicans (ATCC 10231) suspensions were obtained. A sterile denture was placed in a beaker containing the Experimental (ES) or the Control suspension (CS). ES was microwaved at 650 W for 6 min. Suspensions were optically counted using methylene blue dye uptake as indicative of membrane-damaged cells; spread on Agar Sabouraud dextrose (ASD) for viability assay; or spectrophotometrically measured at 550 nm. Cell-free solutions were submitted to content analyses of protein (Bradford and Pyrogallol red methods); Ca++ (Cresolftaleine complexone method); DNA (spectrophotometer measurements at 260 nm) and K + (selective electrode technique). Data were analysed by Student's t- or Wilcoxon z-tests (α = 0.05). All ES cells demonstrated cell membrane damage. Viable cells were non-existent in the ES ASD plates. No significant difference in optical density between ES and CS was observed (P = 0.272). ES cells released significantly high protein (P < 0.001, Bradford; P = 0.005, Pyrogallol red), K+ (P < 0.001), Ca++ (P = 0.012) and DNA (P = 0.046) contents. Microwaves inactivated C. albicans and damaged cell membrane integrity. © 2007 The Authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the effectiveness of different exposure times of microwave irradiation on the disinfection of a hard chairside reline resin. Materials and Methods: Sterile specimens were individually inoculated with one of the tested microorganisms (Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans, and Bacillus subtilis) and incubated for 24 hours at 37°C. For each microorganism, 10 specimens were not microwaved (control), and 50 specimens were microwaved. Control specimens were individually immersed in sterile saline, and replicate aliquots of serial dilutions were plated on selective media appropriate for each organism. Irradiated specimens were immersed in water and microwaved at 650 W for 1, 2, 3, 4, or 5 minutes before serial dilutions and platings. After 48 hours of incubation, colonies on plates were counted. Irradiated specimens were also incubated for 7 days. Some specimens were prepared for scanning electron microscopic (SEM) analysis. Results: Specimens irradiated for 3, 4, and 5 minutes showed sterilization. After 2 minutes of irradiation, specimens inoculated with C. albicans were sterilized, whereas those inoculated with bacteria were disinfected. One minute of irradiation resulted in growth of all microorganisms. SEM examination indicated alteration in cell morphology of sterilized specimens. The effectiveness of microwave irradiation was improved as the exposure time increased. Conclusion: This study suggests that 3 minutes of microwave irradiation can be used for acrylic resin sterilization, thus preventing cross-contamination. © 2008 by The American College of Prosthodontists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To carry out the dating by the Fission Track Method (FTM) the international community that works with this method employs methodologies in which the mineral to be dated must be irradiated with neutrons. Such irradiation, performed in a nuclear reactor, demand a relatively long waiting time so that the activity of the sample attain a proper level for handling. The present work aims to establish a methodology that makes possible the dating by FTM using a mass spectrometer instead of a nuclear reactor. This methodology was applied to apatite samples from Durango, Mexico. © 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this in vitro study was to evaluate the effect of neodymium:yttrium-aluminum-garnet (Nd:YAG) laser irradiation on intracanal dentin surface by SEM analysis and its interference in the apical seal of filled canals. After endodontic treatment procedures, 34 maxillary human incisors were randomly assigned to 2 groups. In the negative control group (n=17), no additional treatment was performed and teeth were filled with vertically condensed gutta-percha; in the laser-treated group (n=17), the root canals were irradiated with Nd:YAG laser (1.5 W, 100 mJ, 15 Hz) before filling as described for the control group. Two specimens of each group were prepared for SEM analysis to evaluate the presence and extent of morphological changes and removal of debris; the other specimens were immersed in 0.5% methylene blue dye (pH 7.2) for 24 h for evaluation of the linear dye leakage at the apical third. SEM analysis of the laser-treated group showed dentin fusion and resolidification without smear layer or debris. The Student's t-test showed that the laser-treated group had significantly less leakage in apical third than the control group. Within the limitations of this study, it may be concluded that the morphological changes on the apical intraradicular dentin surface caused by Nd:YAG laser resulted in less linear dye apical leakage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a climatic and statistical analysis of global, direct horizontal and diffuse radiation from a database of solar radiation measured from 1996 to 2006 in the city of Botucatu, SP, Brazil. Variation intervals of hourly and daily irradiation, annual mean 〈H̄G〉, 〈H̄bh〉 and 〈H̄d〉 irradiation, monthly mean 〈H̄G〉, 〈H̄ bh〉 and 〈H̄d〉 irradiation and monthly mean 〈K̄t〉, 〈K̄bh〉 and 〈K̄d〉 fractions were determined. Results showed that values of hourly and daily annual mean irradiation were as follows: 〈H̄G〉=1.49MJ/m2 and 〈H̄ G〉=17.74MJ/m2; 〈H̄bh〉=0. 90MJ/m2 and 〈H̄bh〉=10.33MJ/m2 and 〈H̄d〉=0.57 MJ/m2 and 〈H̄d〉=7.09MJ/m2, respectively. Variation intervals of hourly monthly mean irradiation were as follows: 〈H̄G〉 ranged from 1.65MJ/m2 in March to 1.16MJ/m2 in June; 〈H̄bh〉 ranged from 1.06MJ/m2 in April to 0.79MJ/m2 in June, and 〈H̄d〉 ranged from 0.70MJ/m2 in January to 0.37MJ/m2 in June and July. Similarly, daily 〈H̄ G〉 irradiation ranged from 21.35MJ/m2 in November to 12.94MJ/m2 in June; 〈H̄bh〉 ranged from 11.83MJ/m2 in April to 8.49MJ/m2 in June, and 〈H̄d〉 ranged from 10.29MJ/m2 in December to 4.38MJ/m2 in June. Variation intervals of hourly monthly mean fractions were as follows: 〈K̄t〉 ranged from 43.5% in January to 54.2% in April; 〈K̄bh〉 ranged from 33.6% in January to 58.0% in April and 〈K̄d〉 ranged from 66.4% in January to 42.0% in April. In the same way, daily 〈K̄ t〉 fractions ranged from 45.5% in January to 59.8% in August; 〈K̄bh〉 ranged from 38.9% in January to 62.0% in August and 〈K̄d〉 ranged from 61.1% in January to 37.7% in July.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. Materials and methods: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). Results and conclusion: Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Clinical significance: Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)