189 resultados para implicit finite difference method


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many new viscoelastic materials have been developed recently to help improve noise and vibration levels in mechanical structures for applications in automobile and aeronautical industry. The viscoelastic layer treatment applied to solid metal structures modifies two main properties which are related to the mass distribution and the damping mechanism. The other property controlling the dynamics of a mechanical system is the stiffness that does not change much with the viscoelastic material. The model of such system is usually complex, because the viscoelastic material can exhibit nonlinear behavior, in contrast with the many available tools for linear dynamics. In this work, the dynamic behavior of sandwich beam is modeled by finite element method using different element types which are then compared with experimental results developed in the laboratory for various beams with different viscoelastic layer materials. The finite element model is them updated to help understand the effects in the damping for various natural frequencies and the trade-off between attenuation and the mass add to the structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The torsional stiffness of chassis is one of the most important properties of a vehicle's structure and therefore its measurement is important. For the first time, the torsional stiffness was considered on the design of a prototype Baja SAE of the team from UNESP - FEG, Equipe Piratas do Vale Bardahl. According to the team's opinion, the increase of stiffness on this prototype, called MB1114, made possible a great improvement in its performance during competitions. In this work, the experimental evaluation of the torsional stiffness from this prototype is performed, detailing the analysis of results, as well as, the hysteresis' effect, least-squares regression and uncertainty analysis. It also shows that it is possible to measure the torsional stiffness of chassis with a low experimental uncertainty without expending many resources. The test rig costed R$ 32,50 due the reuse of materials and the use of instrumentation already available on campus. Furthermore, it is simple to produce and can be easily stocked. Those features are important for Baja and Formula SAE teams. Lastly, the measured value is used to validate the finite element analysis performed by the team during this prototype's design, because similar studies will be performed for the new cars. After investigating the finite element analysis, one result 13,5% higher than the measured value was reached. This difference is believed to be occurred due the imperfections of the finite element model, in other words, for not been possible to simulate every phenomena present on the real model

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Maize gluten feed (MGF) is a co-product of wet milling of maize, and is composed of structures that remain after most starch, gluten and germ has been extracted from the grain. Although currently used in dog foods, its digestibility and energy values have not been documented. Two techniques were used to determine nutrient digestibility of MGF for dog foods. Both techniques used extruded diets fed to Beagle dogs, with six replicates per diet. The first study used a difference method in which 300 g/kg of a reference diet was replaced by MGF. Based on the difference method, the coefficient of total tract apparent digestibility (CTTAD) of MGF was 0.53 for dry matter (DM), 0.69 for crude protein (CP), 0.74 for fat, 0.99 for starch, and 0.55 for gross energy (GE). The calculated metabolizable energy (ME) of MGF was 7.99 MJ/kg (as-fed). The second study used a regression method and included a basal diet and a basal diet with 70, 140 and 210 g MGF/kg of diet (as a substitute for maize starch). Maize gluten feed inclusion resulted in a linear reduction of CTTAD of DM (R(2)=0.99; P<0.001), CP (R(2)=0.95; P=0.002), fat (R(2)=0.87; P=0.009). starch (R(2)=0.81; P<0.001), and GE (R(2)=0.99; P<0.001). Faecal production increased linearly from 56 g to 107 g/dog/d (R(2)=0.99; P<0.001), with a linear reduction of faecal DM (R(2)=0.99: P<0.001) and a linear increase in faecal lactic acid concentration (P<0.02). Both urine (R(2)=0.77; P=0.029) and faeces (R(2)=0.92: P=0.019) showed a linear reduction in pH. Results of ingredient MAD obtained by the regression and difference methods were close (6% or less of variation) for CP, fat, and starch, and also for ME content (1.4% higher for the difference method), but the two methods disagreed on calculated CTTAD of DM and organic matter. The high dietary fiber content of MGF (382 g/kg) may explain the low digestibility of this ingredient. Maize gluten feed could be a useful ingredient for formulations designed to have low energy or reduce the urine pH of dogs. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presents the dynamic modelling of a flexible robotic manipulator with two flexible links and two revolute joints, which rotates in the horizontal plane. The dynamic equations are derived using the Newton-Euler formulation and the finite element method, based on elementary beam theory, which is used to discretize the displacements such that the small motion is represented in terms of nodal displacements. Computer simulation results are presented to illustrate this study. The dynamic model becomes necessary for use in future design and control applications.