263 resultados para implant angulation
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: To survey the current radiographic prescriptions in dental implant assessment amongst dentists in Brazil.Methods: Sixty-nine dentists were interviewed during a dental implant meeting by two calibrated graduate students, using a 19-question questionnaire, considering imaging modality options both for pre-operative implant site assessment and for follow-up, particularly with respect to cost, patient radiation dose, and broad coverage of facial bones and teeth. Epi-Info 6.04 software was used to analyse the database file.Results: Approximately 63.8% of the dentists prescribed only panoramic radiography for dental implant assessment and 28.9% ordered panoramic radiography plus periapical radiography and/or conventional tomography and/or computed tomography (CT). Only 7.2% of the dentists ordered conventional tomography or CT as a single examination, although 10.1% ordered it in combination with other imaging modalities. The main reasons given for prescribing panoramic radiography were broad coverage and cost (86.4%).Conclusions: This study has shown that most of the dentists in this study prescribe panoramic radiographs in dental implant assessment based on broad coverage and cost. They are not following the American Academy of Oral and Maxillofacial Radiology recommendations regarding cross-sectional imaging.
Resumo:
The purpose of this study was to evaluate the influence of the oxidized surface on bone-to-implant contact (BIC%), the bone density in the threaded area (BA %), as well as the bone density outside the threaded area (BD%) in human jaws after 2 months of unloaded healing. Thirteen subjects (mean age 42.61 +/- 6.15 years) received two microimplants (2.5 mm diameter and 6 mm length) each, during conventional mandible or maxilla implant surgery. The microimplants with commercially pure titanium surfaces (machined) and oxidized surfaces served as the control and test surfaces, respectively. After 2 months, the microimplants and the surrounding tissue were removed and prepared for histomorphometric analysis. All microimplants, except two machined and one oxidized microimplant surfaces, were found to be clinically stable after the healing period. Histometric evaluation indicated that the mean BIC % was (21.71 +/- 13.11) % and (39.04 +/- 15.75) % for machined and oxidized microimplant surfaces, respectively. The BD% was higher for the oxidized surface, although there was no difference for maxilla and mandible. The oxidized surface impacted the BA% for the type-IV bone. Data suggest that the oxidized surface presented a higher bone-to-implant contact rate compared with machined surfaces under unloaded conditions, after a healing period of 2 months. (c) 2006 Wiley Periodicals, Inc.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The use of implants to rehabilitation of total edentulous, partial edentulous or single tooth is increasing, it is due to the high rate of success that this type of treatment present. The objective of this study was to analyze the mechanical behavior of different positions of two dental implants in a rehabilitation of 4 teeth in the region of maxilla anterior. The groups studied were divided according the positioning of the implants. The Group 1: Internal Hexagonal implant in position of lateral incisors and pontic in region of central incisors; Group 2: Internal Hexagonal implant in position of central incisors and cantilever of the lateral incisors and Group3 - : Internal Hexagonal implants alternate with suspended elements. The Electronic Speckle Pattern Interferometry (ESPI) technique was selected for the mechanical evaluation of the 3 groups performance. The results are shown in interferometric phase maps representing the displacement field of the prosthetic structure.
Resumo:
Osteodistraction is a clinical reality available for the resolution of bone deficiencies before dental implant placement or in cases where the existing implants are at the wrong position. The objective of this study is to suggest a new possibility for bone distraction, based on tooth-implant bone distractors, in areas were there is the need for extensive alveolar bone recovery, with installed dental implants. This technique presented good results associated with its simplicity and low cost, making it a viable clinical solution for bone tissue augmentation. Although its use is recent, the suggested technique shows the potential to become used widely in attempts to achieve bone-height augmentation, primarily when dental implants are installed and osteointegrated already. (C) 2008 American Association of Oral and Maxillofacial Surgeons
Resumo:
Aim: This article is a case report of a patient in whom the prosthetic planning indicated the necessity of an incisive canal deflation for the correct installation of all implant that is to be osseointegrated.Case Report. In the reopening phase after the bone graft installation, the incisive canal deflation (biopsy of its content) was done and titanium implants were installed with one of them invading the anatomical space occupied previously by the incisive canal. The biopsy analysis showed fragments of the incisive artery and nerve., which are responsible for the anterior upper-tooth pulp, the periodontium vascularization. and the innervation. Front the anastomosis present along with other structures allied with the absence of teeth in the region, there was no detriment to the patient caused by the deflation.Conclusion: Incisive canal deflation is a viable technique in implantology. It can permit ideal prosthetic planning with no detriment to the patient. (Implant Dent 2009;18:473-479)
Resumo:
Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting groove design were divided in three groups: (1) non-fluted (no cutting groove, solid screw-form); (2) fluted (901 cut at the apex, tap design); and (3) Blossomt (Patent pending) (non-fluted with engineered trimmed thread design). The implants were screwed into polyurethane foam blocks and the insertion torque was recorded after each turn of 901 by a digital torque gauge. Controlled lateral loads of 10N followed by increments of 5 up to 100N were sequentially applied by a digital force gauge on a titanium abutment. Statistical comparison was performed with two-way mixed model ANOVA that evaluated implant design group, linear effects of turns and displacement loads, and their interaction. Results: While insertion torque increased as a function of number of turns for each design, the slope and final values increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- standard deviation [SD] = 64.1 +/- 26.8, 139.4 +/- 17.2, and 205.23 +/- 24.3 Ncm, respectively). While a linear relationship between horizontal displacement and lateral force was observed for each design, the slope and maximal displacement increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- SD 530 +/- 57.7, 585.9 +/- 82.4, and 782.33 +/- 269.4 mm, respectively). There was negligible to moderate levels of association between insertion torque and lateral displacement in the Blossomt, fluted and non-fluted design groups, respectively. Conclusion: Insertion torque was reduced in implant macrodesigns that incorporated cutting edges, and lesser insertion torque was generally associated with decreased micromovement. However, insertion torque and micromotion were unrelated within implant designs, particularly for those designs showing the least insertion torque.
Resumo:
Objective: To compare a customized imaging guide and a standard film holder for obtaining optimally projected intraoral radiographs of dental implants.Material and methods: Intraoral radiographs of four screw-type implants with different inclination placed in an upper or lower dental phantom model were recorded by 32 groups of examiners after a short instruction in the use of the RB-RB/LB-LB mnemonic rule. Half of the examiners recorded the images using a standard film holder and the other half used a customized imaging guide. Each radiograph was assessed under blinded conditions with regard to rendering of the implant threads and was assigned to one of four quality categories: (1) perfect, (2) not perfect, but clinically acceptable, (3) not acceptable, and (4) hopeless.Results: For the upper jaw, the same number of exposures per implant were made to achieve an acceptable image (P = 0.86) by the standard film holder method (median = 2) and the imaging guide method (median = 2). For the lower jaw, medians for the imaging guide method and the film holder method were 1 and 2, respectively (P = 0.004). For the imaging guide method, the first exposure was rated as perfect/acceptable in 62% of the cases and for the film holder method in 41% of the cases (P = 0.013). After <= 2 exposures, 78% (imaging guide method) and 69% (film holder method) of the implant images were perfect/acceptable (P=0.23). The implant inclination did not have a major influence on the outcomes.Conclusion: Perfect or acceptable images were achieved after two exposures with the same frequency either using a customized imaging guide method or a standard film holder method. However, the use of a customized imaging guide method was overall significantly superior to a standard film holder method in terms of obtaining perfect or acceptable images with only one exposure.
Resumo:
Purpose: Considering the potential of the association between laser ablation and smaller scale hydroxyapatite (HA) coatings to create a stable and bioactive surface on titanium dental implants, the aim of the present study was to determine, by the removal torque test, the effects of a surface treatment created by laser-ablation (Nd:YAG) and, later, thin deposition of HA particles by a chemical process, compared to implants with only laser-ablation and implants with machined surfaces.Materials and Methods: Forty-eight rabbits received I implant by tibia of the following surfaces: machined surface (MS), laser-modified surface (LMS), and biomimetic hydroxiapatite coated surface (HA). After 4, 8, and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition, and roughness.Results: Average removal torque in each period was 23.28, 24.0, and 33.85 Ncm to MS, 33.0, 39.87, and 54.57 Ncm to LMS, and 55.42, 63.71 and 64.0 Ncm to HA. The difference was statistically significant (P < .05) between the LMS-MS and HA-MS surfaces in all periods of evaluation, and between LMS-HA to 4 and 8 weeks of healing. The surface characterization showed a deep, rough, and regular topography provided by the laser conditioning, that was followed by the HA coating.Conclusions: Based on these results, it was possible to conclude that the implants with laser surface modification associated with HA biomimetic coating can shorten the implant healing period by the increase of bone implant interaction during the first 2 months after implant placement. (C) 2009 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 67:1706-1715, 2009
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Background: Chemical modification of implant surface is typically associated with surface topographic alterations that may affect early osseointegration. This study investigates the effects of controlled surface alterations in early osseointegration in an animal model.Methods: Five implant surfaces were evaluated: 1) alumina-blasting, 2) biologic blasting, 3) plasma, 4) microblasted resorbable blasting media (microblasted RBM), and 5) alumina-blasting/acid-etched (AB/AE). Surface topography was characterized by scanning electron microscopy and optical interferometry, and chemical assessment by x-ray photoelectron spectroscopy. The implants were placed in the radius of six dogs, remaining 2 and 4 weeks in vivo. After euthanization, specimens were torqued-to-interface failure and non-decalcified - processed for histomorphologic bone-implant contact, and bone area fraction-occupied evaluation. Statistical evaluation was performed by one-way analysis of variance (P < 0.05) and post hoc testing by the Tukey test.Results: The alumina-blasting surface presented the highest average surface roughness and mean root square of the surface values, the biologic blasting the lowest, and AB/AE an intermediate value. The remaining surfaces presented intermediate values between the biologic blasting and AB/AE. The x-ray photoelectron spectroscopy spectra revealed calcium and phosphorus for the biologic blasting and microblasted RBM surfaces, and the highest oxygen levels for the plasma, microblasted RBM, and AB/AE surfaces. Significantly higher torque was observed at 2 weeks for the microblasted RBM surface (P < 0.04), but no differences existed between surfaces at 4 weeks (P > 0.74). No significant differences in bone-implant contact and bone area fraction-occupied values were observed at 2 and 4 weeks.Conclusion: The five surfaces were osteoconductive and resulted in high degrees of osseointegration and biomechanical fixation. J Periodontol 2011;82:742-750.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)