109 resultados para fatigue


Relevância:

20.00% 20.00%

Publicador:

Resumo:

About 99% of mechanical failures are consequence of the phenomena of fatigue, which consists on the progressive weakening of the resistant section of a mechanical component due to the growing of cracks caused by fluctuating loadings. A broad diversity of factors influences the fatigue life of a mechanical component, like the surface finishing, scale factors, among others, but none is as significantly as the presence of geometric severities. Stress concentrators are places where fatigue cracks have a greater probability to occur, and so on, the intuit of this work is to develop a consistent and trustfully methodology to determine the theoretical stress concentration factor of mechanical components. Copyright © 2007 SAE International.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of post surface conditioning on the fatigue resistance of bovine teeth restored with resin-bonded fiber-reinforced composite (FRC). Root canals of 20 single-rooted bovine teeth (16 mm long) were prepared to 12 mm using a preparation drill of a double-tapered fiber post system. Using acrylic resin, each specimen was embedded (up to 3.0 mm from the cervical part of the specimen) in a PVC cylinder and allocated into one of two groups (n = 10) based on the post surface conditioning method: acid etching plus silanization or tribochemical silica coating (30 μm SiOx + silanization). The root canal dentin was etched (H2PO3 for 30 seconds), rinsed, and dried. A multi-step adhesive system was applied to the root dentin and the fiber posts were cemented with resin cement. The specimens were submitted to one million fatigue cycles. After fatigue testing, a score was given based on the number of fatigue cycles until fracture. All of the specimens were resistant to fatigue. No fracture of the root or the post and no loss of retention of the post were observed. The methodology and the results of this study indicate that tribochemical silica coating and acid etching performed equally well when dynamic mechanical loading was used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Standard Test Methods (e.g. ASTM, DIN) for materials characterization in general, and for fatigue in particular, do not contemplate specimens with complex geometries, as well as the combination of axial and in-plane bending loads in their methodologies. The present study refers to some patents and the new configuration or configurations of specimens (non-standardized by the status quo of test methods) and a device developed to induce axial and bending combined forces resultants from axial loads applied by any one test equipment (dynamic or monotonic) which possesses such limitation, towards obtaining more realistic results on the fatigue behavior, or even basic mechanical properties, from geometrically complex structures. Motivated by a specific and geometrically complex aeronautic structure (motor-cradle), non-standardized welded tubular specimens made from AISI 4130 steel were fatigue-tested at room temperature, by using a constant amplitude sinusoidal load of 20 Hz frequency, load ratio R = 0.1 with and without the above referred auxiliary fatigue apparatus. The results showed the fatigue apparatus was efficient for introducing higher stress concentration factor at the welded specimen joints, consequently reducing the fatigue strength when compared to other conditions. From the obtained results it is possible to infer that with small modifications the proposed apparatus will be capable to test a great variety of specimen configurations such as: squared tubes and plates with welded or melted junctions, as well as other materials such as aluminum, titanium, composites, polymeric, plastics, etc. © 2009 Bentham Science Publishers Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aramid fiber reinforced polymer composites have been used in a wide variety of applications, such as aerospace, marine, sporting equipment and in the defense sector, due to their outstanding properties at low density. The most widely adopted procedure to investigate the repair of composites has been by repairing damages simulated in composite specimens. This work presents the structural repair influence on tensile and fatigue properties of a typical aramid fiber/epoxy composite used in the aerospace industry. According to this work, the aramid/epoxy composites with and without repair present tensile strength values of 618 and 680MPa, respectively, and tensile modulus of 26.5 and 30.1 GPa, respectively. Therefore, the fatigue results show that in loads higher than 170 MPa, both composites present a low life cycle (lower than 200,000 cycles) and the repaired aramid/epoxy composite presented low fatigue resistance in low and high cycle when compared with non-repaired composite. With these results, it is possible to observe a decrease of the measured mechanical properties of the repaired composites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal transformations on microalloyed steels can produce multiphase microstructures with different amounts of ferrite, martensite, bainite and retained austenite. These different phases, with distinct morphologies, are determinant of the mechanical behavior of the steel and can, for instance, affect the crack path or promote crack shielding, thus resulting in changes on its propagation rate under cyclic loading. The aim of the present work is to evaluate the effects of microstructure on the tensile strength and fatigue crack growth (FCG) behaviour of a 0.08%C-1,5%Mn (wt. pct.) microalloyed steel, recently developed by a Brazilian steel maker under the designation of RD480. This steel is being considered as a promising alternative to replace low carbon steel in wheel components for the automotive industry. Various microstructural conditions were obtained by means of heat treatments followed by water quench, in which the material samples were kept at the temperatures of 800, 950 and 1200 °C. In order to describe the FCG behavior, two models were tested: the conventional Paris equation and a new exponential equation developed for materials showing non-linear FCG behavior. The results allowed correlating the tensile properties and crack growth resistance to the microstructural features. It is also shown that the Region II FCG curves of the dual and multiphase microstructural conditions present crack growth transitions that are better modeled by dividing them in two parts. The fracture surfaces of the fatigued samples were observed via scanning electron microscopy in order to reveal the fracture mechanisms presented by the various material conditions. © 2010 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. Fatigue has been pointed as a fall risk in the elderly; however, the effects of prolonged gait on neuromuscular recruitment and on its pattern remain unknown. The aim of this study was to evaluate the effects of prolonged gait on neuromuscular recruitment levels and spatial-temporal gait variables. Methods. Eight healthy older women (age: 72.63 ± 6.55 years) walked at their preferred walking speed for twenty minutes on a treadmill. The Root Mean Square (RMS) from the vastus-lateralis, femoral biceps, tibialis anterior and lateral gastrocnemius muscles were determined at the first and last minute of the test during the moments of Heel Strike (HS), Terminal Stance and Terminal Swing (TS). In addition, coactivation in the knee and ankle as well as the stride cadence and length were measured in the test. The two RMS data (taken at the first and last minute) were compared by means of a Student's t-test. Results. Twenty minutes of walking induced fatigue in the subjects, as observed through an increase in RMS, notably during the HS and TS. Coactivation was also influenced by the prolonged gait test. The only gait phase where a risk of falling was enhanced was the HS. Nonetheless, subjects developed strategies to maintain a safe motor pattern, which was evidenced by an increase in stride length and a decrease in stride cadence. Conclusion. Tests lasting just twenty minutes on a treadmill were enough to induce fatigue in older adults. However, the level of fatigue was not enough to present a danger or fall risk to elderly individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aluminum alloy 2524 (Al-Cu-Mg) was developed during the 90s mainly to be employed in aircraft fuselage panels, replacing the standard Al 2024. In the present analysis the fatigue crack growth (FCG) behavior of 2524-T3 was investigated, regarding the influence of three parameters: load ratio, pre strain and crack plane orientation of the material. The pre strain of aluminum alloys is usually performed in order to obtain a more homogeneous precipitates distribution, accompanied by an increase in the yield strength. In this work, it was evaluated the resistance of Al 2524-T3 sheet samples to the fatigue crack growth, having L-T and T-L crack orientations. FCG tests were performed under constant amplitude loading at three distinct positive load ratios. The three material conditions were tested: as received(AR), pre strained longitudinally (SL) and transversally (ST) in relation to rolling direction. In order to describe FCG behavior, two-parameter kinetic equations were compared: a Paris-type potential model and a new exponential equation introduced in a previous work conducted by our research group. It was observed that the exponential model, which takes into account the deviations from linearity presented by da/dN versus AK data, describes more adequately the FCG behavior of Al 224-T3 in relation to load ratio, pre strain effects and crack plane orientation. © 2011 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the effect of fatigue induced by an exhaustive laboratory-based soccer-specific exercise on different hamstrings/quadriceps (H:Q) ratios of soccer players. Twenty-two male professional soccer players (23·1 ± 3·4 year) performed maximal eccentric (ecc) and concentric (con) contractions for knee extensors (KE) and flexors (KF) at 60° s-1 and 180° s-1 to assess conventional (Hcon:Qcon) and functional (Hecc:Qcon) ratios. Additionally, they performed maximal voluntary isometric contraction for KE and KF, from which the maximal muscle strength, rate of force development (RFD) and RFD H:Q strength ratio (RFDH:Q) were extracted. Thereafter, subjects were performed an exhaustive laboratory-based soccer-specific exercise and a posttest similar to the pretest. There was significant reduction in Hcon:Qcon (0·60 ± 0·06 versus 0·58 ± 0·06, P<0·05) and in Hecc:Qcon (1·29 ± 0·2 versus 1·16 ± 0·2, P<0·01) after the soccer-specific exercise. However, no significant difference between Pre and Post exercise conditions was found for RFDH:Q at 0-50 (0·53 ± 0·23 versus 0·57 ± 0·24, P>0·05) and 0-100 ms (0·53 ± 0·17 versus 0·55 ± 0·17, P>0·05). In conclusion, H:Q strength ratios based on peak force values are more affected by fatigue than RFDH:Q obtained during early contraction phase. Thus, fatigue induced by soccer-specific intermittent protocol seems not reduce the potential for knee joint stabilization during the initial phase of voluntary muscle contraction. copy; 2012 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stride before landing may be important during stepping down. The aim of this study was to analyze variability of the kinematics and muscle activity in the final stride before stepping down a curb, with and without ankle and knee muscle fatigue. Ten young participants walked at self-selected speed and stepped down a height difference (10-cm) in ongoing gait. Five trials were performed before and after a muscle fatigue protocol (one day: ankle muscle fatigue, another day: knee muscle fatigue). The analysis focused on the trailing leg during the last but one and the last step on the higher level. Kinematics and muscle activity were recorded. Fatigue increased variability of foot-step horizontal distance in the last step on the higher level of the trailing limb, as well as in the first steps on the lower level for both limbs. This appeared due to an increase in the range of motion of the knee joint after both fatigue protocols. Participants additionally showed an increased ankle and hip ROM and decreased knee ROM. Our results suggest a loss of control under fatigue reflected in a higher variability of trailing and leading limb-step horizontal distances, with compensatory changes to limit fatigue effects, such as a redistribution of movement over joints. © 2012 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Artistic Gymnastics is a sport where athletes are frequently fatigued. One element that might influence this aspect is carbohydrate, an important energy substrate for the muscles and the CNS. Our goal was to investigate the influence of fatigue over artistic gymnastics athlete's performance and the effects of a carbohydrate supplementation on their performance. Methods: We evaluated 15 athletes divided in 2 groups (control and fatigue) from 12 to 14 years old in two different experimental days. On the first day (water day), they did 5 sets of exercises on the balance beam (experimental protocol) ingesting only water, CG (control group) warmed up before the experimental protocol and FG (fatigue group) did a fatigue circuit, warm up exercises and then the experimental protocol. On the second day (carbohydrate day), we used the same protocol but CG ingested a sugar free flavored juice and FG ingested a 20% concentration maltodextrin solution before the protocol on the balance beam. Results: We observed a greater number of falls from the balance beam from the FG on the first day (5.40 ± 1.14 FG vs 3.33 ± 1.37 CG; p = 0.024) and a decrease in the number of falls on the second day (2.29 ± 1.25 FG water day vs 5.40 ± 1.14 FG carbohydrate day; p = 0.0013). Carbohydrate solution was able to supply muscle demands and improve the athlete's focus showed by the reduced number of falls. © 2013 Batatinha et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This systematic review aimed to assess changes on spatiotemporal gait parameters due to fatigue. MATERIAL AND METHOD: A search was carried out in literature published from 1950 to December 2010 and retrieved 771 articles using terms referring to walking and fatigue in the title, abstract or keywords. Two researchers assessed the selection and quality of each article independently. RESULTS: Seven studies were selected for this systematic review, two of which reported on the same data set. Several spatiotemporal parameters were reported to change with fatigue, but the few variables studied in multiple studies, gait speed and stride or step length and stride time, were affected only in single studies. Fatigue appears to modulate spatiotemporal gait parameters, but the effects of fatigue appear to be dependent on the muscles that were fatigued, and age that appears to be a moderator of the effects of fatigue on gait. © 2013 - IOS Press and the authors. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The correlative light-electron fractography technique combines correlative microscopy concepts to the extended depth-from-focus reconstruction method, associating the reliable topographic information of 3-D maps from light microscopy ordered Z-stacks to the finest lateral resolution and large focus depth from scanning electron microscopy. Fatigue striations spacing analysis can be precisely measured, by correcting the mean surface tilting with the knowledge of local elevation data from elevation maps. This new technique aims to improve the accuracy of quantitative fractography in fatigue fracture investigations. Microsc. Res. Tech. 76:909-913, 2013. © 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the effect of muscle fatigue in active and inactive young adults on the kinematic and kinetic parameters of normal gait and obstacle crossing. Twenty male subjects were divided into active (10) and inactive (10), based on self-reported physical activity. Participants performed three trials of two tasks (normal gait and obstacle crossing) before and after a fatigue protocol, consisting of repeated sit-to-stand transfers until the instructed pace could no longer be maintained. MANOVAs were used to compare dependent variables with the following factors: physical activity level, fatigue and task. The endurance time in the fatigue protocol was lower for the inactive group. Changes of gait parameters with fatigue, among which increased step width and increased stride speed were the most consistent, were independent of task and physical activity level. These findings indicate that the kinematic and kinetic parameters of gait are affected by muscle fatigue irrespective of the physical activity level of the subjects and type of gait. Inactive individuals used a slightly different strategy than active individuals when crossing an obstacle, independently of muscle fatigue. © 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)