378 resultados para espectroscopia de impedância


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The materials designed to be used in electroluminescent (EL) devices construction are studied and improved since 1936. Great interests in the development of this kind of devices are mainly due to its low power consumption, flexibility, low cost and easy processing. One class of ELs devices with these characteristics are produced by employing a organic-polymeric/inorganic composite from a conductive polymer blend and an inorganic electroluminescent material (Zn2SiO4:Mn) dispersed in the polymeric matrix. This kind of device operates in d.c. or a.c. potentials, with EL of hundreds candela in the green region of the visible spectrum. However, few studies on the light emission were performed for these devices. In order to characterize devices made from composites, in this work is proposed a method of characterizing the electroluminescence associated with the impedance spectroscopy technique. To implement the technique of impedance spectroscopy was employ an experimental setup consisting of a source of a.c. voltage, an oscilloscope, and a reference resistor. Associated with this system, was use a photo diode and an analog electrometer to characterize the emitted light signal from the sample. The system was implemented allows characterization by impedance spectroscopy in the frequency range from 0.2 Hz up to 2 MHz and voltage amplitudes of 5 mV up to 20 kV. This system permits, at the same time, measurement of the RMS value of the luminance for devices in frequency range from 20 Hz up to 2 MHz. To test the system efficiency, an EL device was characterized showing analogous results to those reported in literature. By doing this, was demonstrated the efficiency of the system for electroluminescence characterization associated with the electrical characterization by impedance spectroscopy, for devices

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Biotecnologia - IQ

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Despite the great development of organic and polymeric electroluminescent materials, the large scale commercial application of devices made with these materials seems conditioned to specific cases, mainly due to the high cost and the low durability, in compared to conventional technologies. In this study was produced electroluminescent devices by a process simple, drop casting. Were produced electroluminescent films containing Zn2SiO4:Mn immersed in a conductive polymer blend with different thicknesses. The morphological characteristics of these films were studied by scanning electronic microscopy. These films were used in the manufacture of electroluminescent devices, in which the light emission properties of the developed material were evaluated. The blend was composed of the conductive polymer Poly(o-methoxyaniline), doped with p-toluene sulfonic acid, and an insulating polymer, Poly(vinylidene fluoride) and its copolymer Poly(vinylidene fluoride-cotrifluoroethylene). To this blend was added Zn2SiO4:Mn, thereby forming the composite. A first set of devices was obtained using composites with different weight fraction of polymeric and inorganic phases, which were deposited by drop casting over ITO substrates. Upper electrodes of aluminum were deposited by thermal evaporation. The resulting device architecture was a sandwich type structure ITO/ composite/ Al. A second set of devices was obtained as self-sustaining films using the best composite composition obtained for the device of the first set. ITO electrodes were deposited by RF-Sputtering, in both faces of these films. The AC electrical characterization of the devices was made with impedance spectroscopy measurements, and the DC electrical characterization was performed using a source/ meter unit Keithley 2410. The devices light emission was measured using a photodiode coupled to a digital electrometer, Keithley 6517A. The devices electrooptical characterization showed that the...

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Using the sol-gel process, organic-inorganic hybrid coatings were synthesized by incorporation of different concentrations of functionalized carbon nanotubes, to improve their mechanical strength and thermal resistance without changing its passivation character. The siloxane-PMMA hybrids were prepared by radical polymerization of methyl methacrylate (MMA) with 3-methacryloxipropiltrimethoxisilane (MPTS) using the thermal initiator benzoyl peroxide (BPO), followed by acid catalyzed hydrolysis and condensation of tetraethoxysilane (TEOS). The analysis of pristine and functionalized carbon nanotubes was carried out using Scanning Electron Microscopy, X-ray Photoelectron Spectroscopy and Raman Spectroscopy. Structural analysis of hybrids was performed by Nuclear Magnetic Resonance, Atomic Force Microscopy and Raman Spectroscopy. For analysis of mechanical strength and thermal stability were performed mechanical compression tests and thermogravimetric analysis, respectively. Electrochemical Impedance Spectroscopy was used to evaluate the corrosion resistance in saline environment. The results showed an effective functionalization of carbon nanotubes with carboxyl groups and conservation of its structure. The hybrids showed high siloxane network connectivity and roughness of approximately 0.3 nm. The incorporation of carbon nanotubes in the hybrid matrix did not change significantly their thermal stability. Samples containing carbon nanotubes exhibit good corrosion resistance (on the order of MΩ in saline environment), but the lack of complete dispersion of carbon nanotubes in the hybrid, resulted in a loss of mechanical and corrosion resistance compared to hybrid matrix.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work introduces the results from the performing of impedance spectroscopy on the transition metals oxide Ca1.2La0.8FeIrO6. It was sought to understand the behavior of one sample from its impedance spectra for different AC voltages and temperature values and if an applied external magnetic field at room temperature would cause some change on it. The results revealed that the Ca1.2La0.8FeIrO6 at high temperatures shows conductive and inductive behavior and that the resistance increases with frequency, phenomenon known as Kelvin effect. At 150 K, the spectrum real part no longer consists with the theoretical prediction of Kelvin effect, starting to be influenced by the utilized voltages, condition that inexists on theory. At low temperatures (10, 20, 30 K) it was observed resistive and capacitive behavior, being possible on these conditions, associate to the sample a paralel RC circuit in series with a contact resistance with a fitting from the ZSim software. This fitting allowed the obtaining of capacitance, DC resistance and contact resistance values. The application of a 700G magnetic field at room temperature didn't cause changes on the spectra

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiography (conventional and contrasted - canalography) and audioelectrophysiologic (impedance audiometry) tests were correlated with otitis media in 12 middle ear affected and 12 healthy dogs. When comparing both diagnostic methods, it was found that the reliability in the detection of otitis media in dogs was 100% for the first and 58.3-60.0% for the latter. Thus, it was possible to attest that the impedance audiometry was the most accurate method in the identification of otitis media in dogs when compared with radiographic assessments.