416 resultados para energia nuklearra
Resumo:
A model for preventive control in electrical systems is presented, taking into account the dynamic aspects of the network. Among these aspects, the effects provoked by perturbations which cause oscillations in synchronous machine angles (transient stability), such as electric equipment outages and short circuits, are presented. The energy function is used to measure the stability of the system using a procedure defined as the security margin. The control actions employed are load shedding and generation reallocation. An application of the methodology to a system located in southern Brazil, which is composed of 10 synchronous machines, 45 busses, and 72 transmission lines. The results confirm the theoretical studies.
Resumo:
This paper presents the Benders decomposition technique and Branch and Bound algorithm used in the reactive power planning in electric energy systems. The Benders decomposition separates the planning problem into two subproblems: an investment subproblem (master) and the operation subproblem (slave), which are solved alternately. The operation subproblem is solved using a successive linear programming (SLP) algorithm while the investment subproblem, which is an integer linear programming (ILP) problem with discrete variables, is resolved using a Branch and Bound algorithm especially developed to resolve this type of problem.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this study was to examine the agreement between the results of body fat (BF and BF%), fat-free mass (FFM) and FFM index (FFMI= FFM/height2) as estimated by skinfold anthropometry (ANT), bioelectrical impedance (BIA) and dual-energy X-ray absorptiometry (DXA) in two groups of men (> or = 50 y), one comprising healthy individuals (n=23) and the other, patients with chronic obstructive pulmonary disease (COPD) (n=24). Comparisons between body composition techniques were done by repeated measures ANOVA; the Bland & Altman procedure was used to analyse agreement. RESULTS AND CONCLUSIONS: 1) comparison between healthy and COPD groups showed significant differences between all studied variables; 2) in the healthy group, values for BF, BF%, FFM and FFMI were not significantly different when BIA or ANT was compared to DXA; however, in COPD, values for BF and BF% were significantly higher and for FFM and FFMI significantly lower when BIA was compared to DXA; in contrast, no differences were shown between values for these variables when ANT was compared with DXA; 3) Bland & Altman test, in both groups, showed no agreement between BIA and DXA and between ANT and DXA; it was also shown that body fat was overestimated and fat free mass underestimated by BIA in relation to DXA.
Energia digestível para larvas de tilápia-do-nilo (oreochromis niloticus) na fase de reversão sexual
Resumo:
This experiment was conducted to evaluate different levels of digestible energy on the performance of Nile tilapia larvae (Oreochromis niloticus) during the sexual reversion phase. Three hundred and seventy-five larvae with initial average length and weight of 21.0±4.0 mg and 1.19±0.72 cm, respectively, were allotted to 25 30L-aquarium. A completely randomized design with five treatments and five replicates was used. The aquarium with 15 larvae was the experimental unit. The diets were formulated to contain levels of 3,300, 3,525, 3,750, 3,975, and 4,200 kcal/kg of digestible energy and to be isoprotein (38.6% digestible protein). The animals were fed ad libitum five times a day. At the end of the experiment, the averages of weight (PF), survival rate (SO), condition factor (FC) and length (CF) were analyzed. Linear reduction of fishes PF and CF, as the dietary digestible energy levels increased, was observed. No differences on fish SO and FC of different treatments were observed. Deleterious effects on performance due to the increasing dietary digestible energy levels were noticed for Nile tilapia larvae during the sexual reversion.
Resumo:
This work aimed to study the energy distribution in protected environment during the winter of 2005. A plastic tunnel (27.5 m long, 7.5 m wide, 3.2 m high in the center and 2.00 m high in both lateral sides) was covered with polyethylene 100 micra and black shadow screen (sombrite) in lateral sides at the FCA/UNESP, Botucatu - SP. 142 minievaporimeters (500 ml volume and 147 cm2 area) were evenly distributed and set up at three heights: 0.40 m; 0.80 m and 1.20 m from soil surface in order to analyze energy distribution along the studied area. The greenhouse longitudinal axis was northwest/southeast, based on true north. Geosatistics principles and the GS+ Program were adopted to compare variables. From obtained results, it was concluded that there were significant evaporation variations at different points anf heights; the highest values were the ones closest to the soil surface (0.40m) in July and at highest heights (0.80 and 1.20m). Highest evaporations occurred in the southeastern side of the greenhouse.
Resumo:
This research aims to measure the energy spending in parturient women of low gestation risk. Participants were selected randomly and submitted to fasting (n=15; Group I) or honey ingestion (n = 15; Group II). Data were collected by means of capillary blood values and heart frequency monitoring. The paired t-test with a 5% significance level and Tukey's method were used in statistical analysis. The results showed that honey ingestion did not promote an overload in the mother's glucose; the lactate response demonstrated that the substrate offered was well used; the cardiorespiratory rate demonstrated good performance for both groups; the total energy spent during labor demonstrated that carbohydrate ingestion exerts significant influence, improving maternal anaerobic performance; the group which remained in fasting presented, immediately after labor, higher levels of lactate, showing the organism's efforts to compensate for the energy spent.
Resumo:
This paper discusses the importance of the voltage referential for power quality monitoring and power systempsilas instrumentation. Considering the operating conditions of simple power circuits, it will be demonstrated that an incorrect choice of the voltages referential may result in erroneous quantification of some power quality indices, especially in three-phase four wire circuits. The use of a virtual reference point and the neutral conductor as reference have been considered and the simulation results confirm the influence of the voltage reference selection in the evaluation of total harmonic distortion, unbalance factors and voltage sags. Finally a way of linking both methods will be discussed by means of Blakesleypsilas theorem. © Copyright 2010 IEEE - All Rights Reserved.
Resumo:
The incentive for consumption and production in large quantity in modern society generates enormous amounts of urban solid residues in the form of municipal solid waste (MSW). With the intention of reducing these residues of the municipal waste tips and to generate energy, briquettes with mixtures of MSW and residues of Eucalyptus grandis were produced. The briquettes were manufactured with 0, 5, 10, 15, 20 and 25% of MSW in the mixture with wood waste and 12% of moisture content. The analyzed parameters used to choose the best treatments were combustion analysis versus ash content, mechanical strength and energy content. The briquettes up to 10% of MSW showed low resistance, and above 15% showed large increase in ash content. Therefore, the treatment that fulfilled the requirements for combustion versus ash content and mechanical resistance was of at least 15% of MSW, since the source of the ash is unidentified. Considering the net energy content, the best treatment was 25% of MSW, with 17,175 kJ kg-1. Nevertheless, it is strongly advised that further studies related to gas emissions are necessary.
Resumo:
The objective of this work was to analyze the consumption, electric energy cost, and economic results of irrigated citrus (Citrus sinensis). The treatments consisted of a dripping irrigation system with one and two lateral distribution lines, a micro sprinkler irrigation system and a treatment without irrigation. For each irrigation system, three water depths were used: 100%, 75% and 50% of Etc (citrus evapotranspiration). The electric energy cost for two tariff groups, Group A and Group B, was studied. For Group A, the expenses with energy were determined for the Conventional Binomial Structure tariff, the Hour-seasonal tariff (green and blue) and the special tariff for nocturnal irrigation. The kWh cost for the tariff systems were obtained from the website of CPFL (São Paulo State Power and Light Company, Brazil). The best relation between the electric energy consumption (kWh.ha -1) and productivity (t.ha -1) occurred in the treatment irrigated with 50% of the Etc. The irrigated treatments increased productivity. The biggest productivity was observed in the irrigation treatments with 50% of the Etc when compared to the ones with 100% of the Etc. The blue and green Hour-seasonal tariff system of Group A (nocturnal irrigation) was the best option. A biggest economic turnover occurred in the treatments irrigated with 50% of the Etc.
Resumo:
An economical electricity generating system is developed, i.e., a boiler and turbine with a capacity ≤ 100 kw, to occupy a niche market where the existing steam systems are not economically viable. A Tesla turbine is used. It has been modified to provide greater torque, outperforming the deficiency inherent in the original Tesla turbine. It can operate with saturated steam produced by a boiler heated by biomass, gas, biodiesel, etc. The microgenerator consumes locally available fuel and can bring energy to millions of rural living Brazilians, where some kind of biomass is abundant. The Tesla turbine is compact, has no moving parts, and has endless application possibilities. A prototype system is also created to produce electricity with a boiler and generator.
Resumo:
This paper presents a methodology and software for hazard rate analysis of induction type watt-hour meters, considering the main variables related with the degradation process of these meters, for the Elektro Electricity and Services SA. The modeling developed to calculate the watt-hour meters hazard rate was implemented in a tool through a user friendly platform, in Delphi language, enabling not only hazard rate analysis, but also a classification by risk range, localization of installation for the analyzed meters, and, allowing, through an expert system, the sampling of induction type watt-hour meters, based on the model risk developed with artificial intelligence, with the mainly goal of follow and manage the process of degradation, maintenance and replacement of these meters. © 2010 IEEE.
Resumo:
This experiment was conducted to evaluate the use of different energy levels and amino acid recommendations on performance, carcass yield and intestinal morphometry of broilers from 42 to 57 days of age. We used 1,600 one-day old male broilers (Cobb 500) in a completely randomized design arranged in a 2x4 factorial scheme with 3,200 and 3,600 kcal ME/kg and four different feed programs. The metabolizable energy levels and the feed programs did not determine significant differences in carcass characteristics for choosing a level of energy or a feed program, thus the energy level and the recommendations of amino acids that determine the highest cost-benefit ratio should prevail. It was observed that 3,600 kcal ME/kg resulted in some improvement on performance and morphometry of the intestinal mucosa, also the fractioning of digestible amino acid requirements during two periods resulted in worse performance and intestinal villi height.
Resumo:
The growing concern for renewable and cleaner energy sources has increased the demand for biofuels, pointing out the ethanol from sugarcane. The aim of this study was quantify the partition of energy balance components and monitor the physiological development indexes of the sugarcane, relating them to water availability conditions of climate and soil in Campos dos Goytacazes, Norte Fluminense, Brazil. To this end, a micrometeorological station was settled in an area of 13 ha in commercial cultivation. The culture was regularly monitored at 85, 102, 128, 149, 174, 194, 215, 235, 255 and 280 days after cutting (DAC). The variations in water availability directly influenced the rates of crop growth and energy balance. Under the conditions studied most of the available energy (53%) was consumed by the latent heat flux.