139 resultados para electricity consumption per floor area
Resumo:
Improvement on yield potential of plants by crop management is the main research challenge due to the growing of food demand worldwide. The objective of this work was to study physiological and morphological traits and its relationship with yield components and yield of wheat as affected by sowing densities and plant growth regulators. The experimental design was a split-plot design with four replications. The plots were consisted by four sowing densities ( 30, 50 70 and 90 plants m(-1)) and the subplots were consisted by plant growth regulators [control, (IBA+GA+KT), Trinexapac-Ethyl e (IBA+GA+KT) + Trinexapac-Ethyl]. Dry matter accumulation, plant height, source-sink distance, gas exchange and yield were determined. Trinexapac-Ethyl application resulted in decreasing of plant height, source-sink distance and flag leaf length; however, the grain yield was not affected. The number of plants per unit area affected dry matter accumulation. Higher dry matter accumulation showed direct relationship with yield and yield components in lower plant densities.
Resumo:
The tertiary sector is largely responsible for the growth of electricity consumption in Brazil. The large commercial and public buildings, hypermarkets and shopping centers stand out as major consumers of electricity for lighting, power and thermal energy. Brazil presents significant potential for the deployment of small cogeneration plants, especially in the tertiary sector. Allied to this, the possibility of natural gas supply and the growing demands in favor of maintaining and preserving the environment favor the implementation of cogeneration plants. In this context, this paper presents a technical and economic analysis of installing a cogeneration plant using internal combustion engine with natural gas in a mall
Resumo:
In the industries of wood processing (sawmills), where timber is sawn in equipment such as band saws, circular saws, trowel, thicknessers, among others, that mechanically transform this resource and use of electric motors, which are not unusually poorly scaled working or overloaded, often a factor that is not found in these industries and has fundamental importance in the production process is energy efficiency that is achieved by both technological innovation and through all the practices and policies that aim to lower energy consumption, lowering energy costs and increasing the amount of energy offered no change in generation. For both during the design of an electrical installation, both overall and in various sectors of the installation, investigations are necessary, considerations and uses of variables and factors that put into practice the theme of energy efficiency. Therefore, in this paper, these factors were calculated and analyzed for a wood processing industry (sawmill) in the municipality of Taquarivaí - SP, namely: active power, power factor, demand factor and load factor. Where they were small in relation to the literature, these events that occur when devices are connected at the same time and due to the conditions of processing the wood, where the engines have large variations in electricity consumption during the unfolding of the same, due to efforts with the load and idle moments between each machining operation in the equipment
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
The optimization of energy generation systems has become a key issue for technological and social development, mainly in developing countries, where the electricity consumption rises sharply. Gas turbine cycle is an electricity generating system, which studies have demonstrated that inlet air cooling increases net power and thermal efficiency. Thus, this study intends to quantify these parameters for environments with different ambient temperature and relative humidity. Two types of air cooling were used: evaporative and absorption systems. The configuration parameters only with the gas turbine cycle were compared to those whose configuration allowed cooling. First, it was analyzed only evaporative cooling. Next, the absorption system was used for analysis. The last configuration mixed these two methods, dividing equally its flow. The results showed that thermal efficiency and net power increase in any case of cooling, with absorption system more advantageous in terms of generated energy, where an increase between 1 and 2 MW was observed, depending on the ambient conditions . When the two methods were working together at low relative humidity, it showed a thermal efficiency increase compared to absorption system, up to 2.4%. Evaporative cooling was less effective, but it is a good and cheap possibility to increase the cycle parameters at high temperature and low relative humidity
Resumo:
The population biology of Uca thayeri was studied in a subtropical mangrove in Ubatuba, State of São Paulo, Brazil. Two sampling techniques were used: transect sampling and catch-per-unit-effort. Size frequency distribution, sex-ratio, and reproductive period were analysed. For juvenile crabs (CW < 4.6 mm), the transect procedure was most efficient, while ovigerous females were most collected during the capture effort. Males were most numerous in the transect technique, while in the catch-per-unit-effort there was no difference between sexes. The species showed a different size frequency distribution for each sampling procedure. The reproduction of U. thayeri is seasonal, being more pronounced in the warmer months of the year. However, juveniles occurred all over the year, although more numerous in the colder months. The success of the species in reproductive activity and the constant colonization of the area can be attributed to the availability of food resources and differential occupation of the habitat by ovigerous females.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Treatment of urinary stress incontinence (USI) by intravaginal electrical stimulation (IES) and pelvic floor physiotherapy represents an alternative to other therapies. The purpose of this work was to evaluate the effectiveness of this treatment inpatients with urinary incontinence. From January 1998 to May 2000, 30 women (mean age 54 years) were studied. All patients had USI and 70% urge incontinence; average follow-up was 7 months. Selection criteria were based on clinical history, objective evaluation of perineal musculature by perineometry, and urodynamics. The treatment protocol consisted of three sessions of IES per week for 14 weeks using INNOVA equipment. Physiotherapy was initiated in the fifth week of IES. A significant decrease in the number of micturitions and urgency was observed after treatment (P<0.01). The pad test showed a reduction in urinary leakage from 13.9 to 5.9 g after treatment (P<0.01). Objective evaluation of perineal muscle strength showed a significant improvement in all patients after treatment (P<0.01). A positive correlation was observed between maximum flow rate (Q(max)) and all three variables: urethral pressure profile at rest and on straining (stop test), and abdominal leak-point pressure (ALPP). A positive correlation was also observed between ALPP and the stop test. Over 100 different surgical and conservative treatments have been tried to manage USI. The majority of these procedures reveal that despite progress already made in this area, there is no ideal treatment. Satisfactory results can be achieved with this method, especially with patients who are reluctant to undergo surgery because of personal or clinical problems.
Resumo:
This study proposes the development of thermal and energy consumption maps to generate useful planning information. A residential neighbourhood in a medium-sized city was selected as the study area. In this area, 40 points were taken as urban reference points where air temperatures at the pedestrian level were collected. At the same time, rural temperatures made available by the city meteorological station were registered. Data of electrical energy consumption of the building units (houses and apartments) were collected through a household survey that was also designed to identify the users' income levels. Then, maps were developed so that the configuration of urban heat islands and electrical energy consumption could be visualised, compared and analysed. The results showed that the income level was the most important variable influencing electrical energy consumption. However, a strong relationship of the consumption with the thermal environment was also observed.
Resumo:
Stevia rebaudiana is a traditional crop of Latin America, now rising to international interest thanks to its specific glycosides that are very sweet and still poor of calories making its potential interesting for dietary recommendations. Its short growing cycle makes this species possible as an annual crop also in non tropical areas, including the Mediterranean Basin and parts of Italy, where rainfall or irrigation is available during late spring and summer. One of the main concerns is the quantity of water necessary for the crop and the ideal number of plants per hectare in order to maximize water use efficiency. The present research was carried out in central Italy to compare yields and water consumption in plots with three plant densities (50, 25, 16 plants per square metre). The results show that the most dense plots can give the best results in the area of the trial.