109 resultados para electrical and mechanical stresses
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Titanium alloys are among the most important and frequently used class of biomaterials. In addition to biocompatibility, it is important that an implant material present satisfactory mechanical properties that allow long term use in the body. To improve such properties, different heat treatments are used, as well as doping with oxygen. The presence of interstitial oxygen in the crystal lattice causes deformation, increases the hardness, and causes modifications in anelasticity, thereby decreasing the elastic modulus. In this study, an alloy was prepared by arc melting precursor metals, heat and mechanically treated, and doped with oxygen, resulting in samples with different processing conditions. In each condition, the alloy was characterised in terms of amount of oxygen, X-ray diffraction, and optical microscopy. In addition, properties of the alloy, such as hardness and elastic modulus, were analysed.
Resumo:
In this research the aim was produce a particleboard with alternative materials and evaluated its physical and mechanical characteristics. The raw materials used are residues from sucarcane bagasse (SC) (Saccharum officinarum) and stem leaves of bamboo (B) (Dendrocalamus giganteus), bonded with a bi component adhesive based on castor oil. It was produced particleboards with five different traces: 100% SC, 75% SC+25% B, 50% SC+50% B, 25% SC +75%B and 100 % B. Their physical and mechanical characteristics were evaluated accordingly to Brazilian standard NBR 14810-3. Regarding the results obtained, it can be detached that for physical and mechanical evaluation it is evident a negative relation among the amount the sugarcane bagasse and their physical and mechanical characteristics, that is particleboards with low concentrations of sugarcane bagasse had better results. However all particleboards could be recommended for use as sealing particleboards in the segment of civil construction.
Resumo:
Background and Objectives: Bone remodeling is characterized as a cyclic and lengthy process. It is currently accepted that not only this dynamics is triggered by a biological process, but also biochemical, electrical, and mechanical stimuli are key factors for the maintenance of bone tissue. The hypothesis that low-level laser therapy (LLLT) may favor bone repair has been suggested. The purpose of this study was to evaluate the bone repair in defects created in rat lower jaws after stimulation with infrared LLLT directly on the injured tissue.Study Design/Materials and Methods: Bone defects were prepared on the mandibles of 30 Holtzman rats allocated in two groups (n = 15), which were divided in three evaluation period (15, 45, and 60 days), with five animals each. control group-no treatment of the defect; laser group-single laser irradiation with a GaAlAs semiconductor diode laser device (lambda = 780 nm; P = 35 mW t = 40 s; circle minus = 1.0 mm; D = 178 J/cm(2); E = 1.4 J) directly on the defect area. The rats were sacrificed at the preestablished periods and the mandibles were removed and processed for staining with hematoxylin and eosin, Masson's Trichrome and picrosirius techniques.Results: the histological results showed bone formation in both groups. However, the laser group exhibited an advanced tissue response compared to the control group, abbreviating the initial inflammatory reaction and promoting rapid new bone matrix formation at 15 and 45 days (P < 0. 05). on the other hand, there were no significant differences between the groups at 60 days.Conclusion: the use of infrared LLLT directly to the injured tissue showed a biostimulating effect on bone remodeling by stimulating the modulation of the initial inflammatory response and anticipating the resolution to normal conditions at the earlier periods. However, there were no differences between the groups at 60 days.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This work aims at presenting a no-break system for microcomputers using ultracapacitors in replacement of the conventional chemical batteries. We analyzed the most relevant data about average power consumption of microcomputers, electrical and mechanical characteristics of ultracapacitors and operation of no-break power circuits, to propose a configuration capable of working properly with a microcomputer switching mode power supply. Our solution was a sixteen-component ultracapacitor bank, with a total capacitance of 350 F and voltage of 10.8 V, adequate to integrate a low-capacity no-break system, capable of feeding a load of 180 Wh, during 75 s. Our proposed no-break increases the reliability of microcomputers by reducing the probability of user data losses, in case of a power grid failure, offering, so, a high benefit-cost ratio. The replacement of the battery by ultracapacitors allows a quick no-break recharge and low maintenance costs, since these modern components have a lifetime longer than the batteries. Moreover, this solution reduces the environmental impact and eliminates the constant recharge of the energy storage device.
Resumo:
The objective of this work is to analyze the viability of incorporation in a microcomputer box of a nobreak with an ultracapacitor as energy storage device, substituting the conventional chemical battery. An advantage of this inclusion is cost reduction because a specific metallic or plastic frame won’t be necessary to protect the components of the nobreak; the microcomputer metallic frame offers the necessary protection for both equipments. Moreover, a large quantity of internal space of microcomputers box isn’t used, and is possible to use it to wrap up the nobreak. This work uses data about average power consumption of microcomputers; operation of switching mode power supplies for microcomputers; electrical and mechanical characteristics of ultracapacitors and operation of power circuits of nobreaks, with the purpose of present a study of energy storage capacity that an ultracapacitor should have to allow a safe switching off of a microcomputer in case of electrical network fail. It was noticed that the use of ultracapacitors is feasible to feed an 180 W load for 75 s, using a capacitive bank with sixteen ultracapacitors, with a total capacitance of 350 F and voltage of 10,8 V. The use of the proposed nobreak increases the reliability of the microcomputer by reducing the probability of user data losses in case of an electrical network fail, offering a high cost/benefit product. The substitution of the battery by an ultracapacitor allows a quick nobreak recharge, with low maintenance costs, since ultracapacitors have a lifetime bigger than batteries; beyond reducing the environmental impact, because they don’t use potentially toxic chemical compounds
Resumo:
Several hormonal and physiological changes that occur during pregnancy directly affect gastrointestinal motility (GI), however, very little is known about the relationship between the electrical and mechanical activities of the stomach and its implications. The aim of this study was to compare the female sex hormones, with profiles of gastrointestinal motility using AC biosusceptometry (BAC) in pregnant rats. Seven female Wistar rats (weighing 250-350 g) were used and all procedures were approved by the local Ethics Committee of animal. Laparotomy was performed on anesthetized rats and a magnetic marker (3.5 mm in diameter and 3.0 mm height) was implanted in the distal stomach. After 10 days of recuperation, the mice were put to mate until confirmation of pregnancy. Fed animals were anesthetized (mg pentobarbital 30 / kg) and kept supine for recording the signal with a sensor 30 min BAC placed on the abdominal surface on days 0, 7, 14 and 20 of gestation. Statistical analysis was performed by Student's t test statistical Newman-Keuls and a P value of .05 was considered statistically significant. The frequency of contraction of the stomach was 74 mHz ± 3, 67 ± 7 mHz, 59 mHz ± 6 (p <0.05 vs day -1) and 71 ± 5 mHz on days -0, -7, -14, and -20, respectively. The values of 44 ± 15 pg / mL and 31 ± 9 pg / ml 25 ± 6 pg / ml, 22 ± 9 pg / ml on days -0, -7, -14 and -20, respectively, obtained by 17ß- estradiol were not statistically significant. The values of progesterone were 13 ± 6 pg / ml at 54 ± 15 pg / ml, 127 ± 42 pg / ml (p <0.05 vs day-1), 22 ± 13 pg / mL on day -0, - 7, -14 and -20, respectively. A linear correlation (Pearson's test) between the lower frequency gastric and increased levels of progesterone was 80% (p <0.0000001). Until then, the relationship between changes in motility and hormone were not described in detail, but with the work that we were able to demonstrate the high correlation between progesterone concentration ...
Resumo:
Pós-graduação em Biologia Geral e Aplicada - IBB
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Effects of meperidine or saline on thermal, mechanical and electrical nociceptive thresholds in cats
Resumo:
Objective To measure cutaneous electrical nociceptive thresholds in relation to known thermal and mechanical stimulation for nociceptive threshold detection in cats.Study design Prospective, blinded, randomized cross-over study with 1-week washout interval.Animals Eight adult cats [bodyweight 5.1 +/- 1.8 kg (mean + SD)].Methods Mechanical nociceptive thresholds were tested using a step-wise manual inflation of a modified blood pressure bladder attached to the cat's thoracic limb. Thermal nociceptive thresholds were measured by increasing the temperature of a probe placed on the thorax. The electrical nociceptive threshold was tested using an escalating current from a constant current generator passed between electrodes placed on the thoracic region. A positive response (threshold) was recorded when cats displayed any or all of the following behaviors: leg shake, head turn, avoidance, or vocalization. Four baseline readings were performed before intramuscular injection of meperidine (5 mg kg(-1)) or an equal volume of saline. Threshold recordings with each modality were made at 15, 30, 45, 60, 90, and 120 minutes post-injection. Data were analyzed using ANOVA and paired t-tests (significance at p < 0.05).Results There were no significant changes in thermal, mechanical, or electrical thresholds after saline. Thermal thresholds increased at 15-60 minutes (p < 0.01) and mechanical threshold increased at 30 and 45 minutes after meperidine (p < 0.05). Maximum thermal threshold was +4.1 +/- 0.3 degrees C above baseline at 15 minutes while maximum mechanical threshold was 296 +/- 265 mmHg above baseline at 30 minutes after meperidine. Electrical thresholds following meperidine were not significantly different than baseline (p > 0.05). Thermal and electrical thresholds after meperidine were significantly higher than saline at 30 and 45 minutes (p < 0.05), and at 120 minutes (p < 0.05), respectively. Mechanical thresholds were significantly higher than saline treatment at 30 minutes (p <= 0.05).Conclusion and clinical relevance Electrical stimulation did not detect meperidine analgesia whereas both thermal and mechanical thresholds changed after meperidine administration in cats.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)