130 resultados para bandwidth 3.1 GHz to 10.6 GHz


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a search for the Standard Model Higgs boson with a mass of 105 GeV/c(2) to 145 GeV/c(2) in data corresponding to an integrated luminosity of approximately 450 pb(-1) collected with the D phi detector at the Fermilab Tevatron p (p) over bar collider at a center-of-mass energy of 1.96 TeV. The Higgs boson is required to be produced in association with a Z boson, and the Z boson is required to decay to either electrons or muons with the Higgs boson decaying to a b (b) over bar pair. The data are well described by the expected background, leading to 95% confidence level cross section upper limits sigma (p (p) over bar -> ZH) x B(H -> b (b) over bar) in the range of 3.1 pb to 4.4 pb. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Some 3 - 3 - 1 models predict the existence of a non-perturbative regime at the TeV scale. We study in these models and their supersymmetric extensions, the energy at which the non-perturbative limit and a Landau-like pole arise. An order of magnitude for the mass of the extra neutral vector boson, Z', present in these models is also obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The characteristics, performance, and application of an electrode, namely, Pt vertical bar Hg vertical bar Hg-2(FF)(2)vertical bar Graphite, where FF stands for flufenamate ion, are described. This electrode responds to FF with sensitivity of (-58.6 +/- 1.2) mV decade(-1) over the range 1.0 x 10(-6) - 1.0 x 10(-2) mol L-1 at pH 6.0-9.0 and a detection limit of 7.1 x 10(-7) mol L-1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-25 s) and can be used for a period of 5 months without any considerable change in its performance characteristics. The proposed electrode displayed good selectivity for flufenamate in the presence of several substances as well as in the presence of some carboxylate and inorganic anions. The electrode was successfully applied to the determination of flufenamic acid in pharmaceuticals and human serum samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cento e dez amostras de 11 diferentes marcas de leite ultra alta temperatura (UAT), comercializadas em São José do Rio Preto - SP, foram submetidas à contagem de microrganismos heterotróficos mesófilos viáveis e à pesquisa de bactérias do grupo do Bacillus cereus. A população de microrganismos mesófilos variou de <1,0´10² UFC/ml a >1,0´10(6) UFC/ml. Bactérias do grupo do Bacillus cereus foram verificadas em 13 (11,8%) amostras. Os resultados evidenciaram elevada população de microrganismos indicadores mesófilos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes an electroanalytical method for determining gold(I) thiomalate, aurothiomalate, widely used for treatment of reumatoid arthiritis, using a screen-printed carbon electrode (SPCE). Aurothiomalate (AuTM) was determined indirectly at the same electrode by accumulating it first at -1.5 V vs. printed carbon. At this potential in the adsorbed state, the AuTM is reduced to Au(0), which is then oxidized at two steps at -0.22 V and +0.54 V on SPCE. Using optimized conditions of 60 s deposition time, -1.5 V (vs. printed carbon) accumulation potential, 100 mV s(-1) scan rate, linear calibration graphs can be obtained by monitoring the peak at +0.54 V for AuTM in HCl 0.1 mol L-1 from 1.43 x 10(-6) to 1.55 x 10(-4) mol L-1. A limit of detection obtained was 6.50 x 10(-7) mol L-1, and the relative standard deviation from five measurements of 3.0 x 10(-5) mol L-1 AuTM is 4.5%. The method was successfully applied for AuTM determination in human urine sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The antimicrobial susceptibility of danofloxacin was compared in vitro with ciprofloxacin against mastitogenic Staphylococcus aureus. Danofloxacin was more active than ciprofloxacin, showing minimal inhibitory concentrations (MIC90), minimal bactericidal concentrations (MBC90) and MBC/MIC ratio lower than those of ciprofloxacin. Ciprofloxacin-resistant mutants occurred at higher frequencies (greater than or equal to 10(-6)) than for danofloxacin (10(-9)).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The oxidation of a reactive dye, Cibacron Blue F3GA, CB, (C.I. 61211), widely used in the textile industries to color natural fibers, was studied by electrochemical techniques. The oxidation on glassy carbon electrode occurs in two steps at 2.0 < pH < 10 involving one electron transfer each to the amine group leading to the imide derivative. Stable films of poly-L-lysine (PLL) in the presence of glutaraldehyde (GA) 97.5%:2.5% on glassy carbon electrode can be used to detect low levels of dye using its oxidation peak at +0.75V by voltammetry. Linear calibration graphs were obtained for the CB reactive dye, from 1.0 X 10(-6) to 1.0 X 10(-5) mol L-1 in B-R buffer, pH 2.0, using a pre-concentration off-line during 10 min. The detection limit (3 sigma/slope) was calculated to be 4.5 X 10(-8) mol L-1. Films of PLL can readily be applied for the determination of CB dye bearing aminoanthraquinone as chromophore and chlorotriazinyl as reactive group at concentrations at least 100 times lesser than using a glassy carbon electrode without modification. The method described was applied for the determination of CB dye in tap water and raw water collected from the municipal treatment plant with a recovery of 89.2% +/- 5.4 and 88.0% +/- 6.5, respectively. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Six Welsh gelding ponies were premedicated with 0.03 mg/kg of acepromazine intravenously (i.v.) prior to induction of anaesthesia with midazolam at 0.2 mg/kg and ketamine at 2 mg/kg i.v.. Anaesthesia was maintained for 2 h using 1.2% halothane concentration in oxygen. Heart rate, electrocardiograph (EGG), arterial blood pressure, respiratory rate, blood gases, temperature, haematocrit, plasma arginine vasopressin (AVP), dynorphin, beta-endorphin, adrenocorticotropic hormone (ACTH), cortisol, dopamine, noradrenaline, adrenaline, glucose and lactate concentrations were measured before and after premedication, immediately after induction, every 20 min during anaesthesia, and at 20 and 120 min after disconnection. Induction was rapid, excitement-free and good muscle relaxation was observed. There were no changes in heart and respiratory rates, Decrease in temperature, hyperoxia and respiratory acidosis developed during anaesthesia and slight hypotension was observed (minimum value 76 +/- 10 mm Hg at 40 mins), No changes were observed in dynorphin, beta-endorphin, ACTH, catecholamines and glucose, Plasma cortisol concentration increased from 220 +/- 17 basal to 354 +/- 22 nmol/L at 120 min during anaesthesia; plasma AVP concentration increased from 3 +/- 1 basal to 346 +/- 64 pmol/L at 100 min during anaesthesia and plasma lactate concentration increased from 1.22 +/- 0.08 basal to 1.76 +/- 0.13 mmol/L at 80 min during anaesthesia, Recovery was rapid and uneventful with ponies taking 46 +/- 6 min to stand. When midazolam/ketamine was compared with thiopentone or detomidine/ketamine for induction before halothane anaesthesia using an otherwise similar protocol in the same ponies, it caused slightly more respiratory depression, but less hypotension. Additionally, midazolam reduced the hormonal stress response commonly observed during halothane anaesthesia and appears to have a good potential for use in horses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the relationship between Candida and denture wear during the night. Twenty-four edentulous volunteers were randomly divided into two groups. Group I (GI, n = 11) was composed of volunteers who wore their complete dentures day and night and Group H (GII, n = 13) was composed of volunteers who wore their complete dentures only during the day. Three examination periods were performed for both groups. In GI, the first examination (A) was carried out after overnight denture wearing. Subsequent examinations were conducted after one (B) and seven nights (C) without denture use during sleep. In GII, the first (A) was done without previous use during sleep, and the following were carried out after one (B) and seven nights (C) of overnight denture wearing. Total un-stimulated saliva was collected in a sterile container and cultured in duplicate inside Petri dishes. The values of colony forming units (CFU mL(-1) +/- s.d.) were obtained: GI A - 10.1 x 10(3) +/- 1.2 x 10(4), B - 2.0 x 10(3) +/- 2.6 x 10(3), and C - 2.6 x 10(3) +/- 5.9 x 10(3) and GII: A - 0.4 x 10(3) +/- 0.6 x 10(3), B - 9.4 x 10(3) +/- 17.7 x 10(3) and C - 6.3 x 10(3) +/- 15.3 x 10(3). The mean counts for Candida sp. were expressed as log (CFU + 1) mL(-1) and statistical significance of differences among groups was tested by ANOVA (alpha = 0.05). Multiple comparisons were performed according to Bonferroni test and indicated significant differences between A-B and A-C, but not between B and C for both groups. It was concluded that there is a significant relationship between continuous denture wear and Candida sp.