102 resultados para Unified Power Quality Conditioner (UPQC)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The public consultation n° 018/2014, for review the Module 8 of Procedures of Electricity Distribution (PRODIST), conducted by National Agency of Electric Energy (ANEEL), aims to improve the regulation of power quality, considering the phenomena harmonic distortion, voltage unbalance, voltage fluctuation and short term voltage variation. These regulatory changes impact in the way of analysis and treatment, of power quality disruption, by the electricity distribution. The developed work makes a study about the applications of these new regulatory requests and hopes to contribute with a better understanding. Through power quality measurements, in distribution substations, with different load profiles (industrial, urban and rural), was obtained a real view of the system, under the aspect of power quality, to evaluate the regulation adherence to the current version and proposed. In this case study, although being in accordance with the current methodology, happened a transgression of propose. With a comparative analysis, was possible to identify some phenomena that were more flexible in the proposed revision and others with more severe monitoring

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work evaluates the environmental impact resulting from the natural gas and diesel combustion in thermoelectric power plants that utilize the combined cycle technology (CC), as regarding to Brazilian conditions according to Thermopower Priority Plan JPP). In the regions where there are not natural gas the option has been the utilization of diesel and consequentily there are more emission of pollutants. The ecological efficiency concept, which evaluates by and large the environmental impact, caused by CO2, SO2, NOx and particulate matter (PM) emissions. The combustion gases of the thermoelectric power plants working with natural gas (less pollutant) and diesel (more pollutant) cause problems to the environment, for their components harm the human being life, animals and directly the plants. The resulting pollution from natural gas and diesel combustion is analyzed, considering separately the CO2, SO2, NO2 and particulate matter gas emission and comparing them with the in use international standards regarding the air quality. It can be concluded that it is possible to calculate thermoelectric power plant quantitative and qualitative environment factor, and on the ecological standpoint, for plant with total power of 41441 kW, being 27 170 kW for the gas turbine and 14271 kW for the steam turbine. The natural gas used as fuel is better than the diesel, presenting ecological efficiency of 0.944 versus 0.914 for the latter, considering a thermal efficiency of 54% for the combined cycle. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a new approach and coding scheme for solving economic dispatch problems (ED) in power systems through an effortless hybrid method (EHM). This novel coding scheme can effectively prevent futile searching and also prevents obtaining infeasible solutions through the application of stochastic search methods, consequently dramatically improves search efficiency and solution quality. The dominant constraint of an economic dispatch problem is power balance. The operational constraints, such as generation limitations, ramp rate limits, prohibited operating zones (POZ), network loss are considered for practical operation. Firstly, in the EHM procedure, the output of generator is obtained with a lambda iteration method and without considering POZ and later in a genetic based algorithm this constraint is satisfied. To demonstrate its efficiency, feasibility and fastness, the EHM algorithm was applied to solve constrained ED problems of power systems with 6 and 15 units. The simulation results obtained from the EHM were compared to those achieved from previous literature in terms of solution quality and computational efficiency. Results reveal that the superiority of this method in both aspects of financial and CPU time. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents the application of a multiobjective evolutionary algorithm (MOEA) for optimal power flow (OPF) solution. The OPF is modeled as a constrained nonlinear optimization problem, non-convex of large-scale, with continuous and discrete variables. The violated inequality constraints are treated as objective function of the problem. This strategy allows attending the physical and operational restrictions without compromise the quality of the found solutions. The developed MOEA is based on the theory of Pareto and employs a diversity-preserving mechanism to overcome the premature convergence of algorithm and local optimal solutions. Fuzzy set theory is employed to extract the best compromises of the Pareto set. Results for the IEEE-30, RTS-96 and IEEE-354 test systems are presents to validate the efficiency of proposed model and solution technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The number of citations of a scientific publication or of an individual scientist has become an important factor of quality assessment in science. We report a study of the statistical distribution of the citation index of both scientific publications and scientists. We give numerical evidence that Tsallis (power law) statistics explains the entire distribution over eight orders of magnitude (10-4 to 10(4)). Also, we draw Zipf plots in order to analyze the statistical distribution of the citation index of Brazilian and international physicists and chemists. The relatively small group of Brazilian scientists seems more adequate to explain the dynamics of the citation index. In this case, we find that the distribution of the citation index can also be explained by a gradually truncated power law with similar parameters. We finally discuss possible mechanisms behind the citation index of scientists and scientific publications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O parcelamento da secagem pode ser eficiente tanto no que diz respeito à qualidade final do café, quanto na redução do consumo específico de energia. Diante disso, objetivou-se, com o presente trabalho, avaliar o efeito do teor de água dos frutos no momento da interrupção da secagem e do período de repouso até a retomada da secagem na qualidade do café natural, por meio da análise sensorial e dos testes de condutividade elétrica e lixiviação de potássio. Frutos de café maduros foram colhidos manual e seletivamente e, em seguida, secados ao sol em terreiros de concreto por dois dias e, então, submetidos à secagem mecânica em secadores de camada fixa. Quando o café atingiu os teores de água de 20%, 17% e 14% (base úmida, bu), a secagem foi interrompida e o café permaneceu em repouso por cinco, quinze e trinta dias e, posteriormente, foi secado em secadores mecânicos até o teor de água de 11% (bu). O controle constituiu-se na secagem completa em terreiro. Observou-se que as combinações entre o menor teor de água e o maior período de repouso e entre o maior teor de água e o menor período de repouso, proporcionam menores valores de lixiviação de potássio. A qualidade da bebida melhora progressivamente com o aumento do período de repouso. A interrupção da secagem com teores de água de 17% e 20% (bu) não altera a qualidade do café natural, comparativamente à secagem completa em terreiro.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The physicochemical (pH, fat and total solids content), sensory (appearance, consistency and taste), and rheological characteristics of five different commercial brands of lactic beverages were determined. Rheological measurements were obtained at 5 degreesC and 25 degreesC using a Brookfield rheometer. The experimental data were described by the power law and Herschel-Bulkley models. The ANOVA of the results were conducted using an incomplete block design, and using Tukey test. Samples showed a significant difference (P less than or equal to 0.05%) for fat content and pH. There was a significant difference in total solids content only among Nestle (A), Batavo (C), and Parmalat (D) samples. Sensory evaluation showed more global acceptability for Nestle; however, Nestle and Vigor (E) lactic beverages obtained better results for appearance than for consistency and taste. Batavo obtained the best score for taste. All test samples exhibited non-Newtonian behavior, with thixotropy. Upward curves showed pseudoplastic behavior, while downward curves showed dilatant behavior with the exception of the Nestle sample, at 25 degreesC. Lactic beverages from all brands analyzed showed similar rheological behavior. (C) 2001 Elsevier B.V. Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A total of 1,800 incubating eggs produced by a commercial flock of Cobb broiler breeders was used to determine the effects of storage duration (3 or 18 d) on spread of hatch and chick quality. Chick relative growth (RG) at the end of 7 d of rearing was also determined as a measure of the chick performance. Chick quality was defined to encompass several qualitative characteristics and scored according to their importance. Eggs stored for 3 d hatched earlier than those stored for 18 d (P < 0.05). Hatching was normally distributed in both categories of eggs, and the spread of hatch was not affected by storage time (P = 0.69). Storage duration of 18 d reduced the percentage of day-old chick with high quality as well as average chick quality score (P < 0.05). RG varied with length of egg storage, quality of day-old chick, and the incubation duration (P < 0.05). Eighteen-day storage of eggs not only resulted in longer incubation duration and lower quality score but also depressed RG. Chick quality as defined in this study was correlated to RG and storage time. It was concluded that day-old chick quality may be a relatively good indicator of broiler performance. The results suggest however that in order to improve performance prediction power of chick quality, it would be better to define it as a combination of several qualitative aspects of the day-old chick and the juvenile growth to 7 d.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An optimisation technique to solve transmission network expansion planning problem, using the AC model, is presented. This is a very complex mixed integer nonlinear programming problem. A constructive heuristic algorithm aimed at obtaining an excellent quality solution for this problem is presented. An interior point method is employed to solve nonlinear programming problems during the solution steps of the algorithm. Results of the tests, carried out with three electrical energy systems, show the capabilities of the method and also the viability of using the AC model to solve the problem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes a methodology for power factor control and correction of the unbalanced currents in four-wire electric circuits. The methodology is based on the insertion of two compensation networks, one wye-grounded neutral and other in delta, in parallel to the load. The mathematical development has been proposed in previous work [3]. In this paper, however, the determination of the compensation susceptances is based on the instantaneous values of load currents. The results are obtained using the MatLab-Simulink enviroment

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rain acidity may be ascribed to emissions from power station stacks, as well as emissions from other industry, biomass burning, maritime influences, agricultural influences, etc. Rain quality data are available for 30 sites in the South African interior, some from as early as 1985 for up to 14 rainfall seasons, while others only have relatively short records. The article examines trends over time in the raw and volume weighted concentrations of the parameters measured, separately for each of the sites for which sufficient data are available. The main thrust, however, is to examine the inter-relationship structure between the concentrations within each rain event (unweighted data), separately for each site, and to examine whether these inter-relationships have changed over time. The rain events at individual sites can be characterized by approximately eight combinations of rainfall parameters (or rain composition signatures), and these are common to all sites. Some sites will have more events from one signature than another, but there appear to be no signatures unique to a single site. Analysis via factor and cluster analysis, with a correspondence analysis of the results, also aid interpretation of the patterns. This spatio-temporal analysis, performed by pooling all rain event data, irrespective of site or time period, results in nine combinations of rainfall parameters being sufficient to characterize the rain events. The sites and rainfall seasons show patterns in these combinations of parameters, with some combinations appearing more frequently during certain rainfall seasons. In particular, the presence of the combination of low acetate and formate with high magnesium appears to be increasing in the later rainfall seasons, as does this combination together with calcium, sodium, chloride, potassium and fluoride. As expected, sites close together exhibit similar signatures. Copyright © 2002 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A low-voltage low-power 2nd-order CMOS pseudo-differential bump-equalizer is presented. Its topology comprises a bandpass section with adjustable center frequency and quality factor, together with a programmable current amplifier. The basic building blocks are triode-operating transconductors, tunable by means of either a DC voltage or a digitally controlled current divider. The bump-equalizer as part of a battery-operated hearing aid device is designed for a 1.4V-supply and a 0.35μm CMOS fabrication process. The circuit performance is supported by a set of simulation results, which indicates a center frequency from 600Hz to 2.4kHz, 1≤Q≤5, and an adjustable gain within ±6dB at center frequency. The filter dynamic range lies around 40dB. Quiescent consumption is kept below 12μW for any configuration of the filter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phasor Measurement Units (PMUs) optimized allocation allows control, monitoring and accurate operation of electric power distribution systems, improving reliability and service quality. Good quality and considerable results are obtained for transmission systems using fault location techniques based on voltage measurements. Based on these techniques and performing PMUs optimized allocation it is possible to develop an electric power distribution system fault locator, which provides accurate results. The PMUs allocation problem presents combinatorial features related to devices number that can be allocated, and also probably places for allocation. Tabu search algorithm is the proposed technique to carry out PMUs allocation. This technique applied in a 141 buses real-life distribution urban feeder improved significantly the fault location results. © 2004 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper a comparative analysis of the environmental impact caused by the use of natural gas and diesel in thermoelectric power plants utilizing combined cycle is performed. The objective is to apply a thermoeconomical analysis in order to compare the two proposed fuels. In this analysis, a new methodology that incorporates the economical engineering concept to the ecological efficiency once Cardu and Baica [1, 2], which evaluates, in general terms, the environmental impacts caused by CO2, SO2, NOx and Particulate Matter (PM), adopting as reference the air quality standards in vigour is employed. The thermoeconomic model herein proposed utilizes functional diagrams that allow the minimization the Exergetic Manufacturing Cost, which represents the cost of production of electricity incorporating the environmental impact effects to study the performance of the thermoelectric power plant [3,4], It follows that it is possible to determine the environmental impact caused by thermoelectric power plants and, under the ecological standpoint, the use of natural gas as a fuel is the best option compared to the use of the diesel, presenting ecological efficiency values of 0.944 and 0.914 respectively. From the Exergoeconomic point of view of, it was found out that the EMC (Exergetic Manufacturing Cost) is better when natural gas is used as fuel compared to the diesel fuel. Copyright © 2006 by ASME.