220 resultados para Ultrasonic NDE
Resumo:
Thin films of perovskite-type materials such as PbTiO3, BaTiO3, (Pb,La)TiO3, (Pb, La)(ZrTi)O-3, KNbO3, and Pb(Mg,Nb)03 have been attracting great interest for applications like non-volatile memories, ultrasonic sensors and optical devices. Thin film should be epitaxially grown or at least highly textured since the properties of this anisotropic material depend on the crystallographic orientation. For optical devices, in particular, an epitaxial thin film without defects are essential to reduce optical propagation losses. Pb1-xLaxTiO3 (PLT) where x=0, 13 and 27% thin films were prepared by a chemical method (polymeric precursors method), and deposited by the spin coating technique onto substrates of SrTiO3 (STO) and LaAlO3 (LAO). The films were then beat treated at 500 degrees C in a controlled atmosphere of 0,. The orientation degree of the thin films was obtained from rocking curve technique, by means of X-ray difftaction analysis. A microstructural study revealed that the films were crack-free, homogeneous and have low roughness. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
The ultrasound stimulated and oxalic acid-catalyzed hydrolysis of tetramethoxysilane (TMOS) was studied by means of a heat flux calorimetric method as a function of the initial water/TMOS molar ratio (r) ranging from 2 to 10. The method is based on the time recording of the hydrolysis exothermic heat peak. which takes place in acidulated heterogeneous water-TMOS mixtures under ultrasonic stimulation, accounting for the instantaneous hydrolysis rate. The hydrolysis rate increases from zero up to a maximum value during the heterogeneous step of the process and then diminishes naturally according to the reactant consumption. The total hydrolyzed quantity was found to be slightly increasing with r. The immiscibility gap of the TMOS- water system in the presence of the hydrolysis products has been inferred from the evaluation of the reacted quantity during the heterogeneous step of the reaction and it has been represented in a ternary diagram in the studied r-range.
Resumo:
The kidding intervals (IDP) of dairy goats raised in Southeastern Brazil were studied to quantify the influence of environmental factors and to estimate genetic parameters by means of least squares (MMQ) and restricted maximum likelihood (REML). The data analyzed were obtained from five farms and three breeds (Alpine, Saanen, and Toggenburg). The overall mean and standard error of IDP, as estimated by MMQ, were 339 +/- 12.70 days. The interaction of year x season of parturition influenced IDP. In two of the years studied, goats kidding at the end of the kidding season showed a shorter IDP when compared to those that were kidding after the end of the season. A quadratic trend of IDP over years was observed across the three kidding periods. For the three seasons. IDP increased from 1986 until mid-1989 and decreased thereafter. The heritability and repeatability of IDP, as estimated by MMQ and REML, were: 0.046 +/- 0.071 and 0.103 +/- 0.043, and 0.00026 and 0.08411, respectively. These estimates indicate that little genetic gain can be expected from selection for this trait.
Resumo:
This work describes an efficient, fast, and reliable analytical methodology for mercury determination in urine samples using stripping chronopotentiometry at gold film electrodes. The samples were sonicated in the presence of concentrated HCl and H2O2 for 15 min in order to disrupt the organic ligands and release the mercury. Thirty samples can be treated over the optimized region of the ultrasonic bath. This sample preparation was enough to allow the accurate stripping chronopotentiometric determination of mercury in the treated samples. No background currents and no passivation of the gold film electrode due to the sample matrix were verified. The samples were also analyzed by cold vapour atomic absorption spectrometry (CV-AAS) and good agreement between the results was verified. The analysis of NIST SRM 2670 (Toxic Metals in Freeze-Dried Urine) also validated the proposed electroanalytical method. Finally, this method was applied for mercury evaluation in urine of workers exposed to hospital waste incinerators. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
The aim of this study was to evaluate the number and the diameter of dentin tubules in root canals, in the cervical, middle, and apical thirds, of human and bovine teeth. Twenty-four single-rooted, human premolars were divided into four groups (n = 6): GH1, 10 to 15 years; GH2, 16 to 30 years; GH3, 31 to 45 years; and GH4, 46 to 80 years; and 24 bovine incisors were divided into four groups (n = 6): GB1, central; GB2, lateral first; GB3, lateral second; and GB4, lateral third. The crowns were removed from the specimens, which were then debrided, sectioned longitudinally in the vestibular-lingual direction, and submitted to ultrasonic cleaning. Scanning electron microscopic evaluations were made with 1,000x and 5,000x magnification. According to the root thirds, statistically significant differences were found both for the number and the diameter of dentin tubules, with the cervical third presenting the highest mean values for both specimen types. As regards the number of dentin tubules, it was observed that the bovine specimens presented a significantly higher mean value than the human specimens; this difference was not observed when the diameters of the two types were compared.
Resumo:
The efficiency of methods for the determination of hexachlorobenzene (HCB) and pentachlorophenol (PCP) in soil samples was evaluated. An on-line method was applied for HCB determination. Soil samples were transferred to chromatographic columns prepacked with alumina. The HCB elution was processed with n-hexane. The PCP was extracted from soil samples with n-hexane-acetone in an ultrasonic bath. After re-extraction with K2CO3 solution PCP was acetylated with acetic anhydride. The pentachlorophenyl acetate derivative was then extracted with n-hexane. The HCB and PCP derivative were analyzed by gas chromatography with electron capture detection (GC-ECD). Mean recoveries obtained from soil samples fortified at levels of 0.5; 4 and 20 ng g(-1) ranged from 91 to 100% for HCB, and for PCP, at levels of 10; 40 and 200 ng g(-1), ranged from 88 to 101%. These results demonstrated the efficiency of the proposed methods. (C) 1998 Elsevier B.V. B.V. All rights reserved.
Resumo:
Aim To assess the histological response associated with grey mineral trioxide aggregate (GMTA) and zinc oxide eugenol (ZOE) as root-end filling materials in teeth where the root canals were not filled and the coronal access cavities were not restored.Methodology Periapical lesions were developed in 24 premolar teeth in three dogs. The root canals were prepared and half of them were dried, filled and the coronal access restored (closed). The remaining teeth were not root filled and no coronal restoration was placed (open). Apical root-end resections were performed 3 mm from the apex, and root-end cavities were prepared with ultrasonic tips. These were randomly filled with either ZOE or GMTA in the same number of specimens using MAPSYSTEM device. After 180 days the animals were killed and blocks of tissues removed and processed for histological examination. Periradicular tissue reaction was evaluated, including severity of inflammation and cementum formation. Statistical analysis was performed using ANOVA analysis and Tukey's test.Results A significant difference was found between the levels of inflammation in the periradicular tissues of the GMTA/closed group, compared with the ZOE/open and ZOE/closed groups (P < 0.05) but not between GMTA/closed and GMTA/open groups. Cementum formation was not found over any ZOE specimens but over MTA in all specimens. No microorganisms were found in the interface between the material and the dentinal walls.Conclusions GMTA was associated with less periapical inflammation and tissue response when used as a root-end filling material, even when no root filling or coronal restoration was present.
Resumo:
A kinetic study of the ultrasound-stimulated and acid-catalyzed sonohydrolysis of tetraethyl orthosilicate (TEOS) in solventless TEOS-water heterogeneous mixtures was carried out by means of a calorimetric method as a function of the ultrasound power. The hydrolysis reaction starts in acidulated heterogeneous water-TEOS mixtures after an induction period under ultrasonic stimulation. The ultrasound power seems to play a role on the dynamical coupling of the system originating a continuum upward shifting of the base line during the induction period of sonication. The rate in which the base line is upward shifted diminishes with the power. The best coupling between the ultrasound and the reactant heterogeneous mixtures for this experimental setup was found to occur at 50 W, for which the gelation time was found to be a minimum. The kinetics of the heterogeneous TEOS sonohydrolysis was studied on the basis of a dissolution and reaction modeling. The heterogeneous reaction pathway as deduced from the kinetic study was drawn in a ternary diagram as a function of the ultrasound power. (C) 2006 Elsevier B.V. All rights reserved.
Resumo:
The main variables found on procedure of the dissolution silicate rocks using acid dissolution in teflon open vessel for analysis of micro elements by ICP-AES has been determined. The results obtained for some samples showed strong dependence of the rock mineralogical composition, then it was recommended an alkaline fusion step after acid dissolution. The decomposition procedure use 20 mi of an acid mixture of HF:HNO3 in the proportion 3:1 for a fraction of 250 mg pulverized sample. The recommended temperatures were 60 degrees C for attack and 90 degrees C for acid volatilization. The fusion step with 50 mg LiBO2 at 1000 degrees C may be used if non-attacked residue is observed in the solution. The whole time was 6 h per sample. Nine types os silicate rocks that show mineralogical and chemical different compositions were chosen for obtaining the optimization of the variables. The elements used were Ce, Y, Yb and Zr. In addition, ultrassonic nebulization has been used. The percentual standard deviations obtained for five determinations were 0.7 and 1.4 for triplicate samples. The mineralogical and textural information from the petrographical analysis of the samples indicated the need of increasing the fusion step on the optimized procedure.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The effects of ultrasound on the wound healing process after teeth extractions were studied histologically. The right upper incisor was extracted in 56 rats. They were divided into 2 groups, one control (I) and one experimental (II). Group II received ultrasound stimulation that was applied with the frequency of repetition of 1,000 Hz and pulse length of 2,000 us continuously, during five minutes daily since the extraction day until 24 hours before the death. The rats were sacrificed at 3, 6, 9, 12, 15, 18, and 21 postoperative days. The results showed a precocious granulation tissue formation, faster remodeling of osseous ridges, and consequently acceleration of the alveolar wound healing process.
Resumo:
In the last 30 years several studies have been made to understand the relaxation mechanisms of the hydrogen atoms present in transition metals and their alloys. In this work, we observed the stress-induced ordering of hydrogen atoms around the interstitial oxygen atoms near the niobium matrix atoms. We studied this relaxation process by measuring the attenuation of longitudinal ultrasonic waves. These measurements were made in Nb1.0%Zr polycrystalline alloys at 10 and 30 MHz, pure and doped with 0.7 and 4.2 at.% hydrogen. The results revealed a thermally activated relaxation structure around 202 K and 235 K for 10 MHz and 30 MHz respectively. This relaxation structure increases with increasing hydrogen concentration. © 1994.
Resumo:
Objective: To examine the basis for local wall motion abnormalities commonly seen in patients with ischemic heart disease, computer-controlled isolated muscle studies were carried out. Methods: Force patterns of physiologically sequenced contractions (PSCs) from rat left ventricular muscle preparations under well-oxygenated conditions and during periods of hypoxia and reoxygenation were recorded and stored in a computer. Force patterns of hypoxic-reoxygenating and oxygenated myocardium were applied to oxygenated and hypoxic-reoxygenating myocardium, respectively. Results: Observed patterns of shortening and lengthening closely resemble those obtained from ischemic and non-ischemic myocardial segments using ultrasonic crystals in intact dog hearts during coronary occlusion and reperfusion, and are similar to findings reported in angiographic studies of humans with coronary artery disease. Conclusion: The current study, demonstrating motions of oxygenated isolated muscle preparations which are similar to those in perfused segments of intact hearts with regional ischemia, supports the concept that the multiple motions of both ischemic and non-ischemic segments seen in regional myocardial disease can be explained by interactions of strongly and weakly contracting muscle during the physiologic cardiac cycle.