127 resultados para Toughness.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
The 4340 are classified as ultra-high strength steels used by the aviation industry and aerospace applications such as aircraft landing gear and several structural applications, usually in quenched and tempered condition. In this situation occurs reduction of toughness, which encourages the study of multiphasic and bainitic structures, in order to maintain strength without loss of toughness. In this study, ferritic-pearlitic structure was compared to bainitic and martensitic structure, identified by the reagents Nital, LePera and Sodium Metabisulfite. Sliding wear tests of the type pin-on-disk were realized and the results related to the microstructure of these materials and also to their hardnesses. It is noted that these different microstructures had very similar behavior, concluding that all three tested pairs can be used according to the request level.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In constant searching for alternative biological material to perform implants and new options of experimental animal models, the objective of this investigation was to describe the mechanical properties of the peritoneum paca (Cuniculus paca Linnaeus, 1766) fresh and preserved in 98% glycerin. Samples of fresh and preserved in glycerin for periods of 30, 60 and 90 days were subjected to mechanical tests. Four adult animals, male or female, with mean body weight of eight kilograms, were used for collecting samples of the peritoneum. All tissues preserved in glycerin 98% showed a decrease in stiffness and increase in ductility and toughness. Considering the maximum force applied to the peritoneum, significant increase was observed in values (p<0.01) of samples stored for 60 and 90 days when compared to fresh material. In relation to the stretch variable, an increase was observed in all storage time of glycerin samples, verifying significant difference (p<0.01) when compared with the fresh samples. The variable area also showed significance (p <0.01) between the values of the fresh samples (5.40 mm(2)) and preserved in the glycerin by periods of 30 days (4.50 mm(2)), 60 days (9.00 mm(2)) and 90 days (7.20 mm(2)), thus indicating that the area of this membrane increased by 0.033 mm(2) per day. Generally, it was concluded that the 98% glycerin is a substance effective for the preservation of the peritoneum of the agouti paca, therefore improves its mechanical properties allowing the support membranes greater deformation forces. Thus, the results obtained in mechanical tests of the peritoneum of paca suggest its use as an alternative biological material.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Materiais estruturais utilizados no projeto de equipamentos e instalações industriais podem apresentar mudança de seu comportamento à fratura quando se varia a temperatura. Este tipo de comportamento caracteriza-se pela existência de uma curva de transição, onde 3 regiões ficam bem definidas: os patamares inferior e superior e a região de transição. Na região de transição, os resultados experimentais apresentam alto espalhamento e são bastante dependentes da geometria ensaiada. Para solucionar este problema, foi desenvolvido um modelo analítico experimental, que resultou na edição da norma ASTM E1921-97. O trabalho inclui um estudo da influência de diversas rotas de tratamentos térmicos aplicadas em um aço 4130 utilizado pela indústria aeronáutica, um aço de qualidade API utilizado pela indústria petrolífera e um aço da classe A516 atualmente utilizado pela indústria nacional de vasos de pressão, na microestrutura, propriedades mecânicas de tração e tenacidade à fratura. Os resultados mostraram que o aço 4130 A450, apresentou a melhor correlação entre resistência e tenacidade entre as microestruturas pesquisadas. Este comportamento deve estar associado a rota de tratamento térmico aplicada a esta condição. O tratamento de austêmpera possibilita a formação de bainita que, tradicionalmente é conhecida por apresentar elevados valores de tenacidade. O método proposto pela ASTM pode ser considerado viável para as diversas microestruturas pesquisadas ampliando a aplicação da metodologia que recomenda o ensaio apenas para aços ferríticos. No entanto, a metodologia da Curva Mestra em materiais tratados termicamente deve ser conduzida de forma a se estabelecer parâmetros que considerem as modificações microestruturais sofridas pelo material.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
2,25Cr-1Mo alloy steels are widely used in petrochemical plant equipments working in high temperature conditions because of their good mechanical proprieties in these conditions. Although, when exposed for a long time at high temperature, in the rage of 343 °C to 593 °C, may present the temper embrittlement phenomenon. The component named stripper of assembly converter of fluid catalytic cracking unit (UFCC) of studied plant is manufactured using this material, which is subject to temper embrittlement. The phenomenon of temper embrittlement refers to progressive lose of toughness, making the material brittle. With embrittlement, equipaments manufactured with this material are under risks to suffer brittle fracture in the cool down and start-up situations of them, which can cause catastrophic failures. By this reason, this research studies presence of temper ebrittlement phenomenon on this material. To verify the toughness of the material is conventionally used charpy V-notch test. However, this test requires the removing of samples of the material to make specimens. This fact becomes critical when talk about structural components of an equipment. So, this research also studies a non-destructive test that can be executes in-situ, known as instrumented indentation, as an alternative detection of the phenomenon at the component stripper, by comparative of the mechanical proprieties obtained by conventional tests in similar samples
Resumo:
This research project focused primarily on assessing the impact toughness of the weld and the base material of a steel pipe API 5L X70 submerged arc welded, used to conduct remote oil and gas (linepipes). The analysis followed strictly the Specification for Line Pipe - API 5L Standard, regarding the removal of the specimens of regions-of-proof-long section of the pipe, at 90o and 180o from the welded joint, and mechanical properties of toughness and Charpy-V, both the joint welded as the base material. Specimens of steel tube supplied by Tenaris Confab-SA were sized for tensile and Charpy-V, according to ASTM E 8M and ASTM E23, respectively. The result obtained showed that the API X70 steel tube has high Charpy-V toughness, near to each other at both 90o and 180o from the welded joint of the tube, and both higher than the weld metal. Microstructural and microhardness analysis complemented the present study
Resumo:
The fracture surfaces express the sequence of events of energy release due to crack propagation by linking the relief of the fracture to the loading stresses. This study aims to evaluate the heterogeneity of the critical zone for the advancement of the crack along its entire length in a thermoset composite carbon fiber and epoxy matrix, fractured in DCB testing (Double Cantilever Beam) and ENF (End-Notched Flexure). Investigations were made from image stacks obtained by optical reflection of extended depth from focus reconstruction. The program NIH Image J was used to obtain elevation map and fully focused images of the fracture surface, whose topographies were quantitatively analyzed. The monofractal behavior for DCB samples was assessed as being heterogeneous along the crack front and along the crack for all the conditionings. For the samples fractured in ENF test, there was a strong positive correlation to the natural condition, considering the fibers at 0° for the monofractal dimension and structural dimension (Df and Ds). For fibers at 90° to crack propagation, there was a moderate positive correlation for the textural dimension of natural condition. However, for the samples under ultraviolet condition and those subjected to thermal cycles, there was no correlation between the fractal dimension and fracture toughness in mode II