243 resultados para Total hip arthroplasty revision surgery · tabular reconstruction · Bone loss · Ceramics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of mentoplasty is to improve chin projection. Traditionally, this is accomplished by either mandibular osteotomy or alloplastic implants. However, these procedures are not free of complications. This report describes gliding mentoplasty, a novel, simple technique for chin projection.The 12 patients in this study underwent gliding mentoplasty. By means of a 2-cm intraoral incision, a subcutaneous dissection was made in the caudal direction. The dissection then proceeded in the subperiosteal plane, leaving a 1-cm cuff of muscle attached to the bone, and advanced toward the lower border of the chin. Subsequently, the dissection was extended laterally, and the whole mental area was dissected from the surrounding tissue. Three 2-0 monofilament nylon sutures were placed in the submandibular periosteum and connected through the remaining muscle cuff to the periosteum. These key sutures allowed the submandibular region to slide forward, project the subcutaneous tissue and mentalis muscle, define the labiomental fold, and improve the pogonion projection.Gliding mentoplasty resulted in a symmetric projection of the chin in all cases. In two patients, a submandibular dimple developed, which spontaneously resolved in 1 month. No revision surgery was performed, and no tissue relapse was noted. The mean follow-up period was 24.7 +/- A 5.17 months (range 19-33 months). All the patients were satisfied with the result.Gliding mentoplasty is a simple, easy-to-perform, rapid surgical technique of chin projection that produces low pain, rapid recovery, and excellent cosmetic results.This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have compared the results of the external irrigation technique with those of a double irrigation technique with continuous intermittent movement. Maximum thermal measurements were made in the cortical part of 10 samples of bovine ribs during osteotomy to simulate the preparation of a surgical bed for the installation of dental implants at a depth of 10 mm Twenty specimens were drilled for each group: external irrigation and continuous movement (control group 1, CG1); external irrigation and intermittent movement (control group 2, CG2); double irrigation and continuous movement (test group 1, TG1); and double irrigation and intermittent movement (test group 2, TG2). The double irrigation technique gave significantly better results regardless of the drilling movement used. Thermal increases between samples was 19.2% in group CG1, 10.4% in CG2, 5.4% in TG1, and 3.4% in TG2. The double irrigation technique produced a significantly smaller increase in temperature in the cortical bone during both types of drilling (p = 0.001), which illustrated its greater efficiency compared with that of the external irrigation technique. (C) 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the clinical survival rate of osseointegrated implants placed in the atrophic maxilla that has been reconstructed by means of autogenous bone grafts harvested from a cranial calvarial site. Further, we sought to analyse the level of pen-implant bone after prosthetic rehabilitation and to determine subjective patient satisfaction with the treatment performed. This study conformed to the STROBE guidelines regarding retrospective studies. Twenty-five patients who had received osseointegrated implants with late loading in the reconstructed atrophic maxilla were included in the study. The survival rate and level of pen-implant bone loss were evaluated. A questionnaire related to the surgical and prosthetic procedures was completed. The observed implant survival rate was 92.35%. The mean bone loss recorded was 1.76 mm in the maxilla and 1.54 mm in the mandible. The results of the questionnaire indicated a high level of patient satisfaction, little surgical discomfort, and that the patients would recommend the procedure and would undergo the treatment again. From the results obtained, it is concluded that the cranial calvarial site is an excellent donor area; calvarial grafts provided stability and maintenance of bone volume over the course of up to 11 years.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Craniofacial trauma can lead to several complications. The combined fractures of anterior and posterior walls of the frontal bone are almost always followed by lesions in nasofrontal orifices and disruption of nasofrontal ostia or ducts, a significant factor for the development of early and late complications after sinus fractures. This article reports a case of trauma patient, who underwent neurological evaluation and at first showed good general condition. Computed tomography noted fracture of the anterior and posterior walls of the frontal sinus and small foci of pneumocephalus in the cerebral cortex. The patient was monitored periodically and 9 days after trauma showed increased areas of pneumocephalus in prefrontal cortex, cerebrospinal fluid draining, and large dura mater lesion, with signs of necrosis and inflammation (meningitis). The necrotic tissues were removed, and dura mater was repaired through the approximation with resorbable wire polyglactin 910 5-0, oxidized cellulose application, and bonding with human fibrin sealant (fibrinogen, thrombin, and calcium chloride). Sinusectomy, frontal sinus, and nasofrontal duct obliteration with pedicled pericranium flap were performed. Tomographically, a reanatomization was noted in frontal region, and a 12-month follow-up showed no complication. The use of fibrin glue to repair dura mater lacerations, as well as the pedicle pericranium flap for frontal sinus and nasofrontal duct obliteration, is an efficient method for treating fractures of the frontal bone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Profile enhancement most frequently involves mentoplasty. For this purpose, the author performs conchal grafts to the chin. A total of 28 women aged 15 to 76 years (mean age, 38.11 ± 15.11 years) requested mentoplasty by itself or combined with rhinoplasty, rhytidoplasty, or submental lipoplasty. The conchal cartilage was harvested subperichondrally through a posterior 3-cm incision. The specimen measured 3 x 1 cm, which was sufficient to project the chin 2 to 3 mm. For 4 to 5 mm of projection, both cartilages were used. The graft was positioned under the periosteum and held with two 5-0 nylon sutures. In these cases, the conchal cartilage graft was a suitable option for chin augmentations up to 5 mm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: In view of reports in the literature on the benefits achieved with the use of platform switching, described as the use of an implant with a larger diameter than the abutment diameter, the goal being to prevent the (previously) normal bone loss down to the first thread that occurs around most implants, thus enhancing soft tissue aesthetics and stability and the need for implant inclination due to bone anatomy in some cases, the aim of this study was to evaluate bone stress distribution on peri-implant bone, by using three-dimensional finite element analysis to simulate the influence of implants with different abutment angulations (0 and 15 degrees) in platform switching. METHODS: Four mathematical models of an implant-supported central incisor were created with varying abutment angulations: straight abutment (S1 and S2) and angulated abutment at 15 degrees (A1 and A2), submitted to 2 loading conditions (100 N): S1 and A1-oblique loading (45 degrees) and S2 and A2-axial loading, parallel to the long axis of the implant. Maximum (σmax) and minimum (σmin) principal stress values were obtained for cortical and trabecular bone. RESULTS: Models S1 and A1 showed higher σmax in cortical and trabecular bone when compared with S2 and A2. The highest σmax values (in MPa) in the cortical bone were found in S1 (28.5), followed by A1 (25.7), S2 (11.6), and A2 (5.15). For the trabecular bone, the highest σmax values were found in S1 (7.53), followed by A1 (2.87), S2 (2.85), and A2 (1.47). CONCLUSIONS: Implants with straight abutments generated the highest stress values in bone. In addition, this effect was potentiated when the load was applied obliquely.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the efficacy of platelet-rich plasma regarding healing, pain and hemostasis after total knee arthroplasty, by means of a blinded randomized controlled and blinded clinical study. Methods: Forty patients who were going to undergo implantation of a total knee prosthesis were selected and randomized. In 20 of these patients, platelet-rich plasma was applied before the joint capsule was closed. The hemoglobin (mg/dL) and hematocrit (%) levels were assayed before the operation and 24 and 48hours afterwards. The Womac questionnaire and a verbal pain scale were applied and knee range of motion measurements were made up to the second postoperative month. The statistical analysis compared the results with the aim of determining whether there were any differences between the groups at each of the evaluation times. Results: The hemoglobin (mg/dL) and hematocrit (%) measurements made before the operation and 24 and 48hours afterwards did not show any significant differences between the groups (p > 0.05). The Womac questionnaire and the range of motion measured before the operation and up to the first two months also did not show any statistical differences between the groups (p > 0.05). The pain evaluation using the verbal scale showed that there was an advantage for the group that received platelet-rich plasma, 24hours, 48hours, one week, three weeks and two months after the operation (p < 0.05). Conclusions: In the manner in which the platelet-rich plasma was used, it was not shown to be effective for reducing bleeding or improving knee function after arthroplasty, in comparison with the controls. There was an advantage on the postoperative verbal pain scale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a evolução e a classificação do peso corporal em relação aos resultados da cirurgia bariátrica em mulheres submetidas ao procedimento cirúrgico há mais de dois anos. SUJEITOS E MÉTODO: Foram avaliadas 141 mulheres submetidas à derivação gástrica em Y de Roux (DGYR) com anel de contenção. As participantes foram divididas de acordo com o tempo de pós-operatório e conforme o percentual da perda do excesso de peso (%PEP): < 50; 50 ┤ 75; e, > 75. RESULTADOS: As mulheres do grupo com %PEP < 50 (15,6%) se mantiveram obesas, enquanto aquelas que apresentaram %PEP > 75 (36,2%) situaram-se entre a eutrofia e préobesidade e tiveram menor índice de recuperação tardia de peso em relação aos demais grupos. CONCLUSÃO: A evolução de peso após dois ou mais anos da cirurgia mostrou sua esperada redução com variados graus de resposta, apontando a necessidade de monitoramento, investigação e intervenção para obtenção dos resultados esperados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Veia cava inferior dupla é uma variação anatômica rara cuja prevalência é de 0,2-3%. O implante de filtro de veia cava, quando indicado em casos com duplicidade da veia cava inferior, pode ser realizado de diferentes formas: em ambas as veias cavas; em uma delas, embolizando a anastomose entre ambas; em somente uma delas; ou por implante supra-renal. Relatamos um caso de trombose venosa profunda no pós-operatório de implante de prótese de quadril com contra-indicação para tratamento anticoagulante e cuja cavografia evidenciou duplicidade de veia cava inferior. O implante de filtro de veia cava inferior realizado em posição supra-renal mostrou-se opção adequada e segura.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An 8-year-old male Boxer with a severely contaminated open fracture of the left radius and ulna fracture, produced by a helicopter propeller, was treated using bone transport by the Ilizarov method. Extensive diaphyseal bone loss and soft-tissue vascular damage were present. The radius and ulna were stabilised with an Ilizarov ring external fixator. The bone defect was partially shortened and restored by gradual transport of a bone segment created from proximal segments of the radius and ulna. The external fixator was removed 4fi months after the beginning of the latency period, due to instability caused by osteolysis around the wires. A cast was placed for 3 weeks. Although the bone transport had resulted in formation of approximately 4 cm of bone, the antebrachium showed approximately 50% shortening when compared to the contralateral limb. The infection was eradicated, and the dog was able to bear weight on the operated limb when walking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.