149 resultados para Statistical evaluation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study morphological changes occurring in the neuromuscular junctions (NMJ) of the extensor digitorum longus (EDL) and soleus muscles from albino rats (Rattus norvegicus) submitted to experimental chronic alcoholism were evaluated. Seventy two male animals aged 4 months and weighing on average 400 g were divided into three groups: control, alcoholic and isocaloric. Six rats from each group were anesthetized and sacrificed after 5, 10, 15 and 18 months. The NMJ did not show detectable morphological changes in either muscle after treatment when examined by light microscopy. With respect to the dimensions, statistical analysis demonstrated a tendency to a statistically significant treatment x time interaction for the length of soleus muscle NMJ. The ultrastructural study, however, revealed that the NMJ of the soleus muscle of animals submitted to 18 months of experimental alcoholism presented important morphological alterations. Characteristically, the NMJ of these muscles is located on an elevation on the surface of the muscle fiber, presenting a regular round, oval or elliptical shape and continuous and not very deep synaptic grooves. Approximately 30% of the NMJ of alcoholic rats are irregular in shape, with the sarcolemmal elevations typical of the synapse region being flattened on at least one side, with discontinuous synaptic grooves, and deep and punctiform contacts of the synaptic buds. These data suggest that, although skeletal muscle has a greater natural resistance against the direct or indirect effects of alcohol, some submicroscopic morphological alterations are detectable in the NMJ, especially in muscles with oxidative metabolism (soleus) following long periods of ingestion of alcohol. (C) 2002 Elsevier B.V. Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present study was to evaluate radiographically and bacteriologically apical and periapical repair in dogs' teeth with induced chronic periapical lesions with the use of two different operative techniques (techniques 1 and 2). The study was conducted on 40 root canals of upper and lower premolars from two dogs aged approximately 12 months. Periapical lesions were induced by leaving the root canals exposed to the oral environment for 5 days and then sealing them with zinc oxide-eugenol for 45 days. After this period, radiographic examination revealed the occurrence of a radiolucent lesion and endodontic treatment was started. The two techniques did not differ in terms of chemomechanical preparation, final filling, or type of cement, but differed in terms of irrigating solution and the presence of an antibacterial dressing. Thus 4% to 6% hypochlorite and hydrogen peroxide (10 volumes) were used in technique 1 during chemomechanical preparation and an antibacterial dressing based on calcium hydroxide was applied between sessions, whereas Dakin's fluid (0.5% sodium hypochlorite solution) and a final filling with no antibacterial dressing were used in technique 2. After chemomechanical preparation, the root canals were filled with gutta-percha cones and Sealapex (Sealapex-Sybron, Kerr, Sao Paulo, Brazil), and the animals were killed 270 days after the final filling. Blocks were cut into 6-μm sections and stained by the Brown and Brenn method. Radiographic, histomicrobiologic and statistical analysis permitted us to conclude the following: radiographically there was a marked reduction or even the disappearance of the radiolucent area present before treatment with greater success in the group treated with technique 1 (group I) than in the group treated with technique 2 (group II); the extent of bacterial invasion of dentinal tubules was greater and more intense in group II than in group I; and the amount of microorganisms detected in the ramifications of the apical delta and in the lumen of the root canal was intense in group II and mild or absent in group I. © 1994.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Platelet function and plasma fibrinogen levels were evaluated in 14 patients, 10 males and 4 females, aged 13-59 years bitten by Bothrops genus snakes. There was a statistical difference (p < 0.05) among plasma fibrinogen levels evaluated 24 and 48 hours after envenomation. There was a tendency towards normalization after 48 hours of treatment. The low platelet number was clear in 24-48 hour evaluations with a tendency towards normalization after 48 hours of treatment (p < 0.05). When platelet function was stimulated by collagen and epinephrine, it appeared to be within normal values. On the other hand, when it was stimulated by adenosine diphosphate (ADP), platelet function was hypoaggregated by a single micromol concentration until 48 hours after treatment. At a 3 micromol concentration, there were alterations only before specific treatment (p < 0.05). Fibrinogen levels and fibrin degradation product (FDP) levels appeared to be altered in 83.33% of patients evaluated. The authors suggest that platelet hypoaggregation is related to decreased fibrinogen and increased FDP levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the microleakage of pit and fissure sealants after different surface preparation (invasive technique and laser irradiation) and the use of different materials (fluoride resin-filled sealant, resin-modified glass ionomer cement and adhesive system). Eighty-four pre molars were used in this study, which were divided into seven groups. After the accomplishment of the different treatments, these were submitted to thermocycling process and assess for microleakage by examination under an epifluorescent microscope and scored zero to seven. Two specimens of each group were observed under scanning electron microscope (SEM). The results showed that laser irradiation did not lessen microleakage in pit and fissures when using a filled-resin sealant with fluoride or a resin-modified glass ionomer cement. The use of laser irradiation and adhesive system, followed by a resin-filled sealant with fluoride, showed the lowest microleakage scores in pit and fissures. Comparing this group to the resin-modified glass ionomer cement group, there was statistical significance. The use of a adhesive system decreased microleakage when using a fluoride resin-filled sealant with or without previous laser irradiation; although it was not statistically significant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Seed ageing is natural phenomenon that occurs in all seeds, including those stored in dry and low temperature rooms. Phaseolus vulgaris L. cv. 'Carioca' seeds harvested in five different years were stored in at 15°C. Seed samples were germinated and evaluated according to The Brazilian Rules for Testing Seeds. The newest seed sample was submitted to artificial ageing. Small (∼1g) samples of all materials (naturally and artificially aged) were ground and proteins extracted. Equal quantities of protein were loaded onto the gels and electrophoresis carried out. Although seeds submitted to 24, 48, 72 and 96 hours of artificial ageing did not show any statistical difference (5%) in relation to unaged seeds in physiological parameters related to emergence, some statistically different parameters related to dry matter and length of shoots and roots occurred. A 24 h of artificial ageing at 41°C improved these factors. Protein patterns were changed after 72 h of artificial ageing and naturally aged seeds showed alterations after two years storage at 15°C. Aged seeds, naturally and artificially, had decreasing germination, vigour, and changes in the characteristic banding pattern of proteins. Physiological parameters and electrophoresis examination showed that for naturally aged seeds physiological parameters were more sensitive while artificially aged seeds, (41°C/100% RH), had electrophoretic profiles that were more efficient for seed lot discrimination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The goal of the present study was to evaluate the microleakage on the cementum/dentin and enamel surfaces in Class II restorations, using different kinds of resin composite (microhybrid, flowable, and compactable). Method and materials: Forty human caries-free molars were extracted and selected. Eighty Class II standardized cavities were made in the cervical wall at the cementoenamel junction (CEJ) and at the mesial and distal surfaces. The teeth were divided into four groups: G1 - adhesive system + microhybrid resin composite Z100; G2 - adhesive system + compactable resin composite Prodigy Condensable; G3 - adhesive system + flowable resin composite Revolution + Z100 resin composite; G4 - adhesive system + Revolution fluid resin + compactable resin composite Prodigy Condensable. The adhesive system used in this study was Scotchbond Multi-Purpose Plus. The specimens were thermocycled in baths of 5°C and 55°C for 1,000 cycles and immersed in 50% silver nitrate solution. The specimens then were sectioned and evaluated on degree of dye penetration. Results: The results were evaluated using the nonparametric Kruskall-Wallis test, which showed a statistically significant difference between groups G1 and G4, G2 and G4, and G3 and G4. Conclusions: None of the materials was able to eliminate the marginal microleakage at the cervical wall; the application of a low-viscosity resin composite combined with a compactable resin composite significantly decreased the microleakage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Many studies concluded that the behavior of babies complicated dental care because of child immaturity or the difficulty of establishing acceptable communication and comprehension. Methods: The records of 696 babies were randomly selected from the baby clinic of Araçatuba in Brazil. Patient age ranged from 0 to 36 months. They were divided into 6 groups according to age: Group I-0 to 6 months; Group II-7 to 12 months; Group III-13 to 18 months; Group IV-19 to 24 months; Group V-25 to 30 months; Group VI-31 to 36 months. The behavior of the child was evaluated upon entrance in the dental office and during the first 4 clinical appointments with a clinical exam and oral physiotherapy. The baby was classified as collaborator (C) or noncollaborator (NC). Statistical analysis was performed using Pearson's chi-square method (P< .05). Results: The percentage of NC for Groups II, III, IV, and V (66%), was significantly higher than for groups I (30%) and VI (50%). Conclusions: Babies from 0 to 6 months showed a collaborative behavior; babies from 7 to 30 months showed noncollaborative behavior; and babies from 31 to 36 months showed no statistically significant difference between the percentage of C and NC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present parallel, double-blind investigation was to evaluate the effect of using systemic metronidazole alone or associated to scaling and root planing on adult chronic periodontal disease, monitored at baseline, 30, 60 and 90 days. Twelve subjects were divided into three groups: the first group (Group I - 22 sites) was submitted to scaling and root planing (SRP) alone; the second group (Group II - 30 sites) received SRP and 250 mg of metronidazole (3 times a day for 10 days), and the third group (Group III - 31 sites) was treated with metronidazole alone. The clinical parameters evaluated were probing depth (PD), clinical attachment level (CAL), plaque index (PlI), gingival index (GI) and bleeding upon probing (BP). Microbiological (BANA test) and enzymatic (Pocket Watch) tests were also performed. All three proposed treatments produced significant improvements in clinical conditions of subjects, from baseline, 30, 60 and 90-day period, except for clinical attachment level. The results obtained by microbiological and enzymatic tests did not show statistical differences among the groups for the 90-day period (r = 0.7924 and r = 0.7757, respectively). In relation to clinical parameters, statistical differences among groups were observed only for the gingival index (p = 0.0261) between Groups I and II, and probing depth (p = 0.0124) between Group I and the others. We conclude that the use of systemic metronidazole did not produce additional effects on the microbiological conditions of these patients with chronic periodontal disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Tissue reactions to 4 different implant surfaces were evaluated in regard to the development and progression of ligature-induced peri-implantitis. Materials and Methods: In 6 male mongrel dogs, a total of 36 dental implants with different surfaces (9 titanium plasma-sprayed, 9 hydroxyapatite-coated, 9 acid-etched, and 9 commercially pure titanium) were placed 3 months after mandibular premolar extraction. After 3 months with optimal plaque control, abutment connection was performed. Forty-five days later, cotton ligatures were placed around the implants to induce peri-implantitis. At baseline and 20, 40, and 60 days after placement, the presence of plaque, peri-implant mucosal redness, bleeding on probing, probing depth, clinical attachment loss, mobility, vertical bone loss, and horizontal bone loss were assessed. Results: The results did not show significant differences among the surfaces for any parameter during the study (P > .05). All surfaces were equally susceptible to ligature-induced peri-implantitis over time (P < .001). Correlation analysis revealed a statistically significant relationship between width of keratinized tissue and vertical bone loss (r 2 = 0.81; P = .014) and between mobility and vertical bone loss (r 2 = 0.66; P = .04), both for the titanium plasma-sprayed surface. Discussion and Conclusions: The present data suggest that all surfaces were equally susceptible to experimental peri-implantitis after a 60-day period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This study evaluated the effectiveness of proximal contacts in Class II restorations using two types of matrix bands (steel and polyester) with two different restoration techniques (incremental and with prepolymerized particles). Method and materials: Eighty-eight Class II adjacent restorations using Prodigy resin composite were performed: 44 with the incremental technique (22 with steel matrix bands, 22 with polyester matrix bands) and 44 utilizing prepolymerized resin particles (22 steel matrix, 22 polyester matrix). The restorations were clinically evaluated at baseline and at 6, 12, and 18 months. Proximal contacts obtained immediately after restoration procedure in all restorations were satisfactory. Results: No statistically significant alterations were found in 18 months of evaluation. Conclusion: Regardless of the utilized resin composite, there were no differences in the amount of proximal contact variations with respect to tested techniques and matrices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this experiment is to evaluate the development in height of the plants of four accessions (2 from Parana - accession 1 and 2, one from São Paulo - accession 3, and one from Mato Grosso do Sul State- accession 4). The experimental design was made of randomized blocks, with four treatments (accessions) and four replications. In each plot were planted 24 seedlings. Five evaluations of the height were accomplished, with an interval of two months, starting from the second month after the planting of the seedlings. The results show a significant difference between accession 4 and other three accessions in first evaluation (141.42 % higher than accession 2, the lowest of three and 44.16 % higher than accession 3, the highest of three), demonstrating a higher vigour of this accession on initial stage of its development. In the second and third evaluation, all accessions have no statistical difference, demonstrating a similar level of development at intermedial stages of development. At 5 th evaluation, all accessions have almost the same result, with no statistical difference among them. This is a clear result of similar level of development of this species in these accessions, representing a stabilization of their height development at the end of first year. We concluded that fáfia possesses a strong initial growth, with visible difference among the accessions in the first months. From the eight month on, we observed a slight decrease in the height. This suggests the end of annual cycle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Alkaline materials have shown incompatibility with methylene blue dye in leakage experiments. The goal of the present study was to analyze the effect of different dyes on the evaluation of the apical sealing ability of Mineral Trioxide Aggregate root-end fillings. Fifty-six extracted human canines were submitted to root canal instrumentation and obturation. After apical resection, retrograde cavities were prepared and teeth were randomly divided into four experimental (n = 13) and two control groups (n = 2). The following root-end filling materials were used: groups 1 and 2--Pro Root MTA (Dentsply), groups 3 and 4--zinc oxide-eugenol cement (ZOE). Teeth in groups 1 and 3 were immersed in 2% methylene blue solution, while teeth in groups 2 and 4 were immersed in 0.2% rhodamine B in a reduced pressure environment for 48 hours. Teeth were then longitudinally sectioned and leakage was evaluated. Results were submitted to statistical analysis (ANOVA and Tukey's test). Group 1 presented the least leakage (p < 0.05). It was concluded that the evaluation of the sealing ability of MTA is influenced by the dye used, since this material presented better sealing ability when evaluated with Methylene Blue, but was similar to ZOE when evaluated with rhodamine B.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate the influence of coronal filling and apical perforation on the induction of periapical inflammation. Methodology: Fifty-eight root canals in the teeth of dogs were divided into four groups. Groups I and II: root canals were exposed for 180 days; groups III and IV: root canals were exposed for 7 days and then the access cavity filled for 53 days. The root apices of groups I and III were perforated after the coronal opening, whilst those of groups II and IV remained intact. Standard radiographs were taken before and after the experimental periods. Digital images of the radiographs were created and then analysed by three examiners. After induction of periapical inflammation, the root canal contents were collected using paper points. Microbiologic evaluation of the type of microorganism was carried out by culture in different growth media. The radiographic and microbiologic data were statistically analysed using ANOVA at a 5% significance level. Results: There were a greater total number of microorganisms in groups I and II (P < 0.05). The number of anaerobes was greater than the number of aerobes (P < 0.05). The size of the periapical radiolucencies were not significantly different between the experimental groups. Conclusions: The different methods analysed induced similar areas of periapical radiolucency in dogs with predominantly anaerobic bacteria. However, the time required for induction was less when the method with coronal filling was used. © 2005 International Endodontic Journal.