273 resultados para Split tensile strength


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study evaluated the effect of heat treatment on CrNi stainless steel orthodontic archwires. Half of forty archwires of each thickness - 0.014 (0.35 mm), 0.016 (0.40 mm), 0.018 (0.45 mm) and 0.020 (0.50 mm) (totalling 160 archwires) - were subjected to heat treatment while the remainder were not. All of the archwires had their individual thickness measured in the anterior and posterior regions using AutoCad 2000 software before and after compressive and tensile strength testing. The data was statistically analysed utilising multivariance ANOVA at a 5% significance level. All archwires without heat treatment that were subjected to tensile strength testing presented with anterior opening, which was more accentuated in the 0.020 archwires. In the posterior region, the opening produced by the tensile force was more accentuated in the archwires without heat treatment. There was greater stability in the thermally treated archwires, especially those subjected to tensile strength testing, which indicates that the heat treatment of orthodontic archwires establishes a favourable and indispensable condition to preserve the intercanine width.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: To characterize the interaction of 1-Ethyl-3-[3-dimethylaminopropyl] carbodiimide Hydrochloride (EDC) with dentin matrix and its effect on the resin-dentin bond. Methods: Changes to the stiffness of demineralized dentin fragments treated with EDC/N-hydroxysuccinimide (NHS) in different solutions were evaluated at different time points. The resistance against enzymatic degradation was indirectly evaluated by ultimate tensile strength (UTS) test of demineralized dentin treated or not with EDC/NHS and subjected to collagenase digestion. Short- and long-term evaluations of the strength of resin-dentin interfaces treated with EDC/NHS for 1 h were performed using microtensile bond strength (mu TBS) test. All data (MPa) were individually analyzed using ANOVA and Tukey HSD tests (alpha = 0.05). Results: The different exposure times significantly increased the stiffness of dentin (p < 0.0001, control-5.15 and EDC/NHS-29.50), while no differences were observed among the different solutions of EDC/NHS (p = 0.063). Collagenase challenge did not affect the UTS values of EDC/NHS group (6.08) (p > 0.05), while complete degradation was observed for the control group (p = 0.0008, control-20.84 and EDC/NHS-43.15). EDC/NHS treatment did not significantly increase resin-dentin mu TBS, but the values remained stable after 12 months water storage (p < 0.05). Conclusions: Biomimetic use of EDC/NHS to induce exogenous collagen cross-links resulted in increased mechanical properties and stability of dentin matrix and dentin-resin interfaces. (C) 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 94B: 250-255, 2010.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives. The purpose of this paper is to modify the conventional calcium fluoro-aluminosilicate glass, which is used in the formation of glass ionomer cements (CIGs) by the niobium addition and to study the properties of GICs obtained.Materials and methods. Sol-gel process was used to prepare the powder at lower temperature than fusion method. Glass-ceramic powder obtained in this way was used to prepare the GICs. The properties such as working and setting times, microhardness and diametral tensile strength were evaluated for the experimental GICs and a commercial luting cement.Results. The ideal powder:liquid (P:L) ratio determined to prepare the experimental GICs was equal to 1:1. The cements prepared using this ratio showed working and setting times similar to the commercial GICs. in mechanical tests it was observed that microhardness and diametral tensile strength of the experimental GICs decreased significantly with the reduction of P:L ratio. on the other hand, the results obtained in microhardness tests indicated that the presence of niobium was a positive factor.Significance. The chemical process allows the development of glass-ceramic powder at 600 degrees C which is the goal of the present paper. It was concluded that GICs containing niobium might be used in dental applications and these results encourage further researches on other compositions. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this paper is to compare the fluoride-releasing and mechanical properties of an experimental luting glass ionomer cement, which has a modified composition and a commercial luting cement. The experimental powder was obtained by sol-gel process and then, it was used to prepare the experimental cements. The properties of cement pastes, such as setting time and working time, microhardness and diametral tensile strength were determined. Fluoride release from GICs was evaluated at time intervals of 1, 7, 14, 21 and 28 days in deionized water. Atomic force microscopy (AFM) analyses showed that the surface of the experimental cements is more homogeneous than commercial GICs. The mechanical properties and the measure of liberation of fluoride of the two cements were influenced by ratio powder:liquid and chemical composition of the precursor powders. Experimental cements released less fluoride than commercial cements. However, this liberation was more constant during the analyzed period. Thus, the results obtained in this study indicated that the composition of the experimental powder modified by the niobium can lead the formation of the polysalt matrix with good mechanical properties. In other words, we can say that experimental powder offered considerable promise for exploitation in dental field.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este trabalho teve por objetivo avaliar a quantidade de finos gerada por diferentes reagentes de branqueamento e seu efeito nas propriedades físicas e mecânicas da celulose kraft de eucalipto. A polpa foi branqueada por quatro sequências diferentes. Parte das amostras foi classificada em equipamento Bauer-McNett, sendo a parte não classificada (global) refinada para 40 ºSR, em moinho laboratorial PFI. As duas maiores porções de cada amostra proveniente da classificação foram também refinadas com o mesmo número de revoluções que a sua amostra global. Realizaram-se ensaios físicos e mecânicos das amostras refinadas, e suas fibras foram analisadas em equipamento FQA (Fiber Quality Analyser), antes e depois do refino. A maior quantidade de finos foi observada nas polpas refinadas e na sequência-referência. Os resultados de tração foram mais elevados e significativos nas amostras globais; as polpas classificadas não apresentaram diferença entre si, sendo atribuída a maior resistência à tração na presença de finos. A resistência ao rasgo foi afetada pelo comprimento das fibras e não pelo teor de finos. Os maiores valores de ascensão capilar Klemm ocorreram nas amostras classificadas em razão da ausência de finos e do maior comprimento de fibras.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo deste experimento foi comparar a sutura contínua e a sutura com pontos separados no fechamento da parede abdominal. Foram utilizados 48 ratos machos Wistar, submetidos a laparotomia com técnica de diérese padronizada, 24 submetidos a sutura da parede abdominal por técnica contínua e 24 com pontos separados, com fio polidioxanona. No 7º e 14º dia de pós-operatório foram submetidos a eutanásia 12 animais de cada grupo e deles retirados a camada músculo-fascial abdominal envolvendo a cicatriz operatória e dividida aleatoriamente em dois segmentos (cranial e caudal), um para ser submetido a avaliação da força de rotura mediante o uso de tensiômetro e outro para exame histológico, onde foi realizada a avaliação quantitativa de colágeno na linha de sutura. Os resultados encontrados foram analisados estatisticamente. Concluiu-se que no 7º dia de pós-operatório a parede abdominal suturada com pontos separados é mais resistente, porém sem diferenças significantes na quantidade de colágeno, do que a suturada por técnica contínua, e no 14º dia, ambas se equivalem nos dois parâmetros estudados, em ratos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este trabalho avaliou a ação do Diclofenaco de Sódio (DS) na cicatrização de anastomoses realizados no íleo terminal de ratos, tendo sido analisados os seguintes parâmetros: evolução clínica, resistência mecânica, colágeno tecidual e alterações histopatológicas. Foram utilizados 519 ratos Wistar divididos em 4 grupos experimentais. O Grupo 1: Controle sem anastomose, 52 ratos tratados com solução fisiológica (SF)3 ml/kg de peso, administrada por via intra-muscular (IM) por 4 dias; Grupo 2: 110 ratos submetidos à anastomose no íleo terminal + SF; Grupo 3: 52 ratos tratados com DS na dose de 3 mg/kg de peso por dia, IM, por 4 dias e o Grupo 4: 295 ratos tratados com DS e submetidos à anastomose no íleo terminal, recebendo DS de maneira idêntica ao grupo anterior. Dez animais sem manipulação, foram utilizados para medidas da força de ruptura e dosagens bioquímicas, com obtenção de parâmetros caracterizados como MO. Os parâmetros foram analisados no 4o, 7o, 14o e 21o dia de pós-operatório. Os animais do Grupo 1 não apresentaram alterações clínicas durante o período de acompanhamento. No Grupo 3, 15,4% dos animais apresentaram diarréia. Neste grupo houve uma diminuição do colágeno tecidual e da força de ruptura quando comparados com o grupo 1. Entre os animais submetidos à anastomoses no íleo terminal, observou-se taxa de mortalidade maior nos animais que receberam DS, além de retardo na cicatrização, caracterizado por uma maior reação inflamatória polimorfonuclear, retardo na regeneração da mucosa, diminuição de macrófagos e do colágeno tecidual. Pelos resultados obtidos concluiu-se que o DS é deletério à evolução cicatricial de anastomoses realizadas no íleo terminal de ratos

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)