173 resultados para Sensitivity and Specificity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the accuracy of Image Tool Software 3.0 (ITS 3.0) to detect marginal microleakage using the stereomicroscope as the validation criterion and ITS 3.0 as the tool under study.Materials and Methods: Class V cavities were prepared at the cementoenamel junction of 61 bovine incisors, and 53 halves of them were used. Using the stereomicroscope, microleakage was classified dichotomously: presence or absence. Next, ITS 3.0 was used to obtain measurements of the microleakage, so that 0.75 was taken as the cut-off point, and values equal to or greater than 0.75 indicated its presence, while values between 0.00 and 0.75 indicated its absence. Sensitivity and specificity were calculated by point and given as 95% confidence interval (95% CI).Results: The accuracy of the ITS 3.0 was verified with a sensitivity of 0.95 (95% CI: 0.89 to 1.00) and a specificity of 0.92 (95% CI: 0.84 to 0.99).Conclusion: Digital diagnosis of marginal microleakage using ITS 3.0 was sensitive and specific.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the efficacy of a dip slide test for mutans streptococci in caries risk assessment, when the microbiological results were compared to well-defined clinical criteria (DCC) for caries risk, clinically measured through high and low caries activity. Eighty-one volunteers from the 6(th) to 8(th) grades from public schools of Piracicaba, São Paulo, Brazil, were evaluated for dental caries. All free smooth surfaces were evaluated to check whether or not there were white spots. Based on the subjects' caries experience, a calibrated clinician divided them into groups of high and low caries activity. The subjects were submitted to a salivary test (CARITEST SM (R)) from the same batch number. Kappa statistics (kappa) were applied to verify the reproducibility of the simplified test, checked through interexaminer agreement when the results were classified by independent and blind means. The microbiological results were validated according to expressions of sensitivity and specificity. A moderate agreement was verified as the results were classified according to 6 scores (kappa =0.55), and the agreement was substantial when the results were classified according to high and low microbiological count (kappa =0.78). The sensitivity and specificity values were 0.59 and 0.85, respectively, showing that the test was more specific than sensitive, and could thus better identify the low caries risk subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Desequilíbrio é um dos muitos fatores de risco que aumenta a susceptibilidade de um idoso a quedas. O equilíbrio pode ser avaliado mediante testes posturais e de sensibilidade plantar. OBJETIVO: Avaliar a ocorrência de desequilíbrio e perda de sensibilidade cutânea plantar em idosos da comunidade e verificar a existência de associação entre ambas as alterações. CASUÍSTICA E MÉTODOS: Estudo transversal descritivo envolvendo 45 idosos submetidos à escala de equilíbrio de Berg (EEB) e ao teste de sensibilidade plantar com monofilamento de nylon. Foram utilizados os testes qui-quadrado e exato de Fisher e elaboradas curvas ROC para estudo da sensibilidade e especificidade da EEB. RESULTADOS: Idosos com alteração do equilíbrio e da sensibilidade cutânea foram em número de 2 e 4, respectivamente. Houve associação significativa entre queixa de desequilíbrio e perda da sensibilidade (p = 0,047) e ocorreu concordância razoável (Kappa: 0,6457) entre a EEB e o teste da sensibilidade. Verificou-se também associação significativa entre 6 dos 14 tarefas da EEB e o teste sensorial. CONCLUSÃO: Idosos vivendo com independência na comunidade, em sua maioria, apresentam equilíbrio e sensibilidade cutânea plantar normais. Quando alteradas estas funções mostram-se associadas de forma que, se os testes forem realizados conjuntamente, a precisão da avaliação do equilíbrio idoso aumenta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O sistema Diramic foi avaliado para o diagnóstico das infecções do trato urinário (ITU). O sistema Diramic foi desenvolvido em Cuba e possibilita resultados de diagnóstico das infecções do trato urinário (ITU) em quatro horas e baseia-se na variação da turvação do crescimento microbiano no meio de cultura após incubação a 37ºC/4 horas. 396 amostras de urinas provenientes de ambulatórios e enfermarias do HC da FMB-UNESP-Botucatu/SP foram analisadas pelo sistema Diramic. O método da alça calibrada (AC) foi adotado como método de referência. A taxa de coincidência entre os dois métodos foi de 96,46% (382 amostras de urina), não havendo diferença significativa entre os resultados obtidos nos dois métodos. Os resultados para sensibilidade e especificidade foram 84,37 e 98,80% respectivamente e 10 resultados no Diramic foram falsos negativos (2,5%) e 4 falso positivos (1,01%). Os microrganismos identificados nas urinas positivas foram Escherichia coli (68,75%), Klebsiella pneumoniae (10,94%), leveduras (6,25%), Pseudomonas aeruginosa (4,69%), Enterobacter cloacae (3,12%) e Proteus mirabilis, Staphyloccocus coagulase negativo, Morganella morganii e Citrobacter freundii também foram identificadas (1,56% para cada espécie). O método Diramic foi eficiente na triagem das urinoculturas, porém verificou-se algumas restrições quanto ao diagnóstico das infecções do trato urinário quando causadas por leveduras e em pacientes submetidos a antibioticoterapia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oxacillin is the main drug of choice for the treatment of S. aureus infections. However, S. aureus resistance to oxacillin has become a major problem in the recent decades. The study aimed assess the rates of oxacillin resistance in S. aureus samples obtained at the Botucatu Medical School Hospital, UNESP, and to compare phenotypic techniques for the detection of MRSA against the gold standard method (mecA gene detection) in these samples. A total of 102 samples, previously isolated between 2002 and 2006, and kept at the Culture Collection of the Department of Microbiology and Immunology, in the Botucatu Biosciences Institute, UNESP, were included. Oxacillin resistance was assessed by oxacillin and cefoxitin disk diffusion and agar dilution tests, screening tests using Mueller-Hinton agar with 6 mu g/mL of oxacillin and 4% NaCl, E-test, and mecA gene detection. of the samples analyzed, 46 (45.1%) were mecA-positive. Oxacillin disk sensitivity and specificity were 86.9% and 91.1%, respectively. Cefoxitin disk sensitivity and specificity were respectively 91.3% and 91.1%. The screening test with the cefoxitin disk showed almost the same level of sensitivity (91.3%) and specificity (91.1%). With E-test strips, sensitivity was higher (97.8%) and specificity was comparable to that found with the other methods (91.1%). Ninety-three percent of the samples produced beta-lactamase and five of them were mecA-negative. There was a gradual increase in the number of oxacillin-resistant S. aureus samples between 2002 and 2004. However, from 2004 to 2006, the number of resistant samples dropped from 55% of MRSA in 2004, to 45% in 2005 and 34.6% in 2006. The data obtained reveal that, among phenotypic methods, the E-test yielded the best results, with higher sensitivity levels when compared to the other methods. The decreased resistance rate observed over the most recent years may be explained by the rational use of antimicrobial agents associated with good practices in the control of hospital infection, or may be related to the diminished use of oxacillin as a treatment option.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

FUNDAMENTO: A obesidade está ligada à hipertensão arterial (HA) na infância. Entretanto, o papel da gordura como preditor de HA em adolescentes permanece desconhecido. OBJETIVO: Investigar a associação entre obesidade geral e abdominal com HA e identificar a sensibilidade e especificidade desses indicadores para detectar HA em adolescentes. MÉTODOS: A amostra consistiu em 1.021 adolescentes com idade de 10-17 anos. Os indivíduos foram classificados como normal, sobrepeso/obesidade, de acordo com as medidas do IMC, e como não-obeso com obesidade abdominal, de acordo com as medidas da circunferência da cintura (CC). A pressão arterial sistólica (PAS) e diastólica (PAD) foi avaliada através de um dispositivo oscilométrico. Regressão logística e curvas ROC foram usadas na análise estatística. RESULTADOS: A prevalência geral de HA foi 11,8% (13,4% em meninos e 10,2% em meninas). A prevalência de HA em meninos e meninas com sobrepeso/obesidade foi 10% e 11,1%, respectivamente. A prevalência de HA em meninos com obesidade abdominal foi 28,6%. Para ambos os sexos, o odds ratio (OR) para HA foi mais alto na obesidade abdominal do que no sobrepeso/obesidade geral (4,09 [OR IC95% = 2,57-6,51]) versus 1,83 [OR IC95% = 1,83-4,30]). O OR para HA foi mais alto quando sobrepeso/obesidade geral e obesidade abdominal estavam agrupados (OR = 4,35 [OR IC95% = 2,68 -7,05]), do que quando identificados como sobrepeso/obesidade geral ou obesidade abdominal apenas (OR = 1,32 [OR IC95% = 0,65- 2,68]). Entretanto, ambos os tipos de obesidade apresentavam baixo poder preditivo na detecção de HA. CONCLUSÃO: Obesidade geral e obesidade abdominal foram associadas com HA; entretanto, a sensibilidade e especificidade dessas variáveis na detecção de HA são baixas em adolescentes brasileiros.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coagulase-negative staphylococci (CNS) species identification is still difficult for most clinical laboratories. The scheme proposed by Kloos and Schleifer and modified by Bannerman is the reference method used for the identification of staphylococcal species and subspecies; however, this method is relatively laborious for routine use since it requires the utilization of a large number of biochemical tests. The objective of the present study was to compare four methods, i.e., the reference method, the API Staph system (bioMérieux) and two methods modified from the reference method in our laboratory (simplified method and disk method), in the identification of 100 CNS strains. Compared to the reference method, the simplified method and disk method correctly identified 100 and 99% of the CNS species, respectively, while this rate was 84% for the API Staph system. Inaccurate identification by the API Staph method was observed for Staphylococcus epidermidis (2.2%), S. hominis (25%), S. haemolyticus (37.5%), and S. warneri (47.1%). The simplified method using the simple identification scheme proposed in the present study was found to be efficient for all strains tested, with 100% sensitivity and specificity and proved to be available alternative for the identification of staphylococci, offering, higher reliability and lower cost than the currently available commercial systems. This method would be very useful in clinical microbiology laboratory, especially in places with limited resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: A sensibilidade de indicadores antropométricos e laboratoriais, na detecção da desnutrição protéico-energética de cirróticos foi estudada em 117 adultos, com gravidades (Child-Pugh), Child A (18), B (42) e C (57). RESULTADOS: Os indicadores antropométricos mais alterados foram: a circunferência braquial 61%, a prega cutânea tricipital 55% e a prega cutânea subescapular 53%, e os laboratoriais: albumina 93% e hemoglobina 90%. Com a combinação de indicadores circunferência braquial + prega cutânea subescapular + albumina ou hemoglobina, alcançaram-se 29% de déficit, valor idêntico ao da associação apenas de circunferência braquial + prega cutânea subescapular. Essa combinação (circunferência braquial e prega cutânea subescapular) detectou 63% de desnutrição protéico-energética, com predominância das formas moderada e grave em todos os graus Child. CONCLUSÃO: A desnutrição protéico-energética na cirrose hepática é predominantemente protéica, podendo ser caracterizada por indicadores laboratoriais (mais sensíveis) ou, com maior especificidade, pela circunferência braquial, embora inespecífica à discriminação da gravidade da desnutrição protéico-energética entre os grupos Child B e C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

No presente estudo pretendeu-se verificar a sensibilidade toxicológica e especificidade do Teste de Microfixação de Complemento (MCF) na detecção de toxinas botulínicas C e D no sobrenadante de cultivos bacterianos e em fígados de camundongos inoculados com doses letais e subletais. As toxinas foram produzidas em meio de cultura Hemoline, tituladas através da determinação da DL50 pelo Bioensaio em Camundongo e diluídas nas concentrações de 10, 1, 0,1, 0,01 e 0,001 DL50. Desta forma, foram utilizadas em dois modelos experimentais, onde foi determinada a sensibilidade toxicológica do MCF no sobrenadante do meio de cultura com as diluições descritas acima e ainda em extratos hepáticos de camundongos com peso corporal de 20g, inoculados com as mesmas diluições. A tentativa de evidenciação das toxinas botulínicas nos extratos hepáticos de camundongos foi realizada através da sua extração após a morte pela administração das doses letais e ainda pelo sacrifício dos animais inoculados com doses subletais, em intervalos de 5 dias. Os resultados evidenciaram uma sensibilidade toxicológica para o MCF de 100% para os dois tipos de toxinas ao nível de 0,01 DL50, quando testados os sobrenadantes de meio de cultura, portanto 100 vezes superior ao Bioensaio em Camundongo. A sensibilidade toxicológica do MCF, quando examinados extratos hepáticos de camundongos inoculados com 1 e 10 DL50 de toxinas botulínicas C e D, foi inferior, com valores de 100, 80, 89 e 72%, respectivamente. Pelo teste foi possível detectar toxinas botulínicas tipos C e D nos extratos hepáticos de camundongos inoculados com doses subletais até 15 dias após a sua inoculação. A especificidade do MCF foi de 88 e 92%, quando testados extratos hepáticos de camundongos sadios, e confrontados com as antitoxinas C e D; e 100% no sobrenadante do meio de cultura. Os resultados apontam para uma possível utilização do teste como importante instrumento de pesquisa e ainda na eventual substituição dos testes in vivo pelas suas implicações éticas e limitações práticas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Uma prova de imunoadsorção enzimática (ELISA) para detecção de anticorpos contra Babesia bovis foi desenvolvida e avaliada em comparação à imunofluorescência indireta (IFI). A sensibilidade e especificidade do ELISA, determinadas pela análise de 100 soros positivos de bovinos infectados experimentalmente com B. bovis e 108 soros negativos colhidos de bovinos livres de infecção por este hemoparasito, foram de 98,0% e 98,1%, respectivamente. Os valores preditivos positivo e negativo foram, respectivamente, 98,0% e 98,1% e a precisão do teste foi de 98,1%. Não foram detectadas reações cruzadas com 80 soros de bezerros experimentalmente inoculados com Babesia bigemina. O ELISA foi comparado à IFI usando 110 soros de rebanhos de área de estabilidade endêmica e 168 soros de rebanhos de áreas de instabilidade endêmica. em ambos os casos, houve concordância significativa (P=0,631 e 0,4725, respectivamente) entre os resultados demonstrados pelos dois testes. em um estudo epidemiológico realizado com o ELISA na região do Pantanal de Mato Grosso do Sul, com 1.365 soros de bovinos, 83,9% foram positivos para anticorpos contra B. bovis, caracterizando a região estudada como endemicamente estável.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Com o intuito de se estudar a presença de suínos portadores renais de leptospiras foram colhidas 131 amostras sanguíneas e os respectivos rins de animais durante o abate em abatedouro da região de Botucatu-SP. Pela prova de Soroaglutinação Microscópica obteve-se 48 amostras sorológicas positivas para um ou mais sorovar de Leptospira spp., com uma taxa de ocorrência de anticorpos anti-leptospira de 36,64%, e maior importância para o sorovar icterohaemorrhagiae. Para a pesquisa do agente nos rins, das 88 amostras renais submetidas a cultura em meio de EMJH e analisadas pela prova de PCR, foi isolado e detectado o agente em uma única amostra renal, pertencente a um animal soropositivo. Embora não tenha sido possível a comparação estatística, em termos de sensibilidade e especificidade das duas provas de detecção do agente a partir de amostras renais, a PCR mostrou-se mais rápida e prática na pesquisa de portadores renais. Pelo isolamento obtido, ressalta-se a importância desses animais como possíveis transmissores da doença para trabalhadores de abatedouro e inspetores de carne.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to 'detect occlusal caries.Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site.Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy far the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly.Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the Sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure.Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and sensitive chemiluminescence assay for the demonstration of the activity of intracellular myeloperoxidase (MPO) is described, which is useful for the distinction between myeloid and lymphoid commitment in blasts from acute leukemia patients. When the cut-off point was settled at 13 mV of chemiluminescence all cases of acute myeloid leukemia (AML) were distinguished from those of acute lymphoid leukemia. In addition, this technique was able to demonstrate MPO activity in AML poorly differentiated (FAB-M0) which usually does not stain for MPO in classical cytochemistry preparations and could be negative also by immunocytochemistry with anti-MPO monoclonal antibody. Therefore the method here described presented a higher sensitivity than the immunocytochemistry procedure with anti-MPO.