119 resultados para NERVE BLOCK
Resumo:
Background and Objectives - Pulmonary aspiration of gastric content during induction of anesthesia for emergency surgical procedures is a serious complication; fast endotracheal intubation under these circumstances is of vital importance to secure the airways. Despite its numerous side effects, succinylcholine is used for this purpose. Rocuronium is the most recently introduced aminoesteroid neuromuscular blocking drug with short onset. The objective of this study was to compare the onset time and intubating conditions of rocuronium and succinylcholine. Methods - After informed consent, forty-five patients were randomly allocated into three groups of 15: Group I (GI) = succinylcholine 1 mg.kg-1; Group II (GII) = rocuronium 0.6 mg.kg-1; Group III (GIII) = rocuronium 0.9 mg.kg-1. Every patient was premedicated with midazolam 15 mg per os and induction of anesthesia was made with fentanyl 10 μg.kg-1 and etomidate 0.3 mg.kg-1. The neuromuscular block was monitored with the TOP-Guard neuromuscular transmission monitor. The TOP-Guard neuromuscular monitor uses an accelerometer to measure the response to nerve stimulation. The stimulating electrodes were placed close to the course of the ulnar nerve at the wrist. The onset time was considered as the time between the end of neuromuscular drug injection and the twitch height (T1) decrease to 10%. Heart rate and arterial blood pressure were registered at 6 moments before and after induction of anesthesia. Results - The onset time results were: Group I, 71 s; Group II, 120 s and Group III, 70 s or GI = GIII < GII (F = 8.862; p < 0.01). There were 43 patients exhibiting excellent intubating conditions and 2 with good intubating conditions. Heart rate and arterial blood pressure showed alterations due to induction of anesthesia and intubation. Conclusions - Rocuronium 0.9 mg.kg-1 can be used in rapid sequence induction because it has a short onset time which is similar to that of succnylcholine. It is likely that rocuronium would be a good indication in patients with high intracranial pressure, burns and neuromuscular diseases.
Resumo:
Nerve regeneration in a sensory nerve was obtained by the application of different techniques: inside-out vein graft (IOVG group) and standard vein graft (SVG group). These techniques provide a good microenvironment for axon regeneration in motor nerves, but their efficiency for regeneration of sensory nerves is controversial. The saphenous nerve was sectioned and repaired by the inside-out and standard vein graft techniques in rats. After 4, 12, and 20 weeks the graft and the distal stump were observed under electron microscopy. In each studied period, the pattern, diameters, and thickness of the myelin sheaths of the regenerated axons were measured in the graft and distal stump. A comparative study about the regenerated nerve fibers by these two different techniques was performed. Regenerated nerve fibers were prominent in both vein grafts 4 weeks after the surgical procedures. On the other hand, in the distal stump, regenerated nerve fibers were observed only from 12 weeks. In both inside-out vein graft and standard vein graft statistical difference was not observed about the diameters and thickness of the myelinated fibers after 20 weeks. On the other hand, the inside-out group had greater regenerated axon number when compared to the standard group. There is a capillary invasion in both graft and distal stump, especially in the IOVG group. The regenerated axons follow these capillaries all the time like satellite microfascicles. After 20 weeks, the diameters of regenerated fibers repaired by the standard vein graft technique were closer to the normal fibers compared to the inside-out vein graft. On the other hand, the pattern of these regenerated axons was better in the IOVG group.
Resumo:
Background and Objectives - Successful cadaver kidney transplantation relies on a fast procedure. Patients with chronic renal failure may present with a delayed gastric emptying making it critical a fast tracheal intubation and airway maintenance. Rocuronium a recently introduced nondepolarizing neuromuscular blocker with a fast onset. The aim of this study was to evaluate onset time and duration of rocuronium effects in patients undergoing renal transplantation. Methods - Sixty patients were allocated into two groups of 30: Group R (GR) = patients undergoing renal transplantation and Group N (GN) = patients with normal renal function. All patients were premedicated with oral midazolam (15 mg) and anesthesia was induced with 30 μg.kg-1 alfentanil, 0.3 mg.kg-1 etomidate and 0.6 mg.kg-1 rocuronium injected through a central venous catheter. neuromuscular block was monitored by acceleromyography in the ulnar nerve pathway. The following parameters were evaluated: time between administration of rocuronium and first twitch reduction to 5% after supra-maximal stimulation (T1) (onset time = OT); time for first twitch to return to 25% (clinical duration = R25); time elapsed between 25% and 75% recovery of first twitch (relaxation recovery time = R25-75). Heart rate (HR) and mean blood pressure (MBP) were recorded in 6 moments. Results - Median OT was 31 sec. in GR and 47 sec. in GN. Median R25 was 51.5 min in GR and 33.5 min in GN. Median R25-75 was 28 min in GR and 20 min in GN. MBP and HR were higher in GR. Tracheal intubation conditions were excellent for most patients in both groups. Conclusions - These results open the possibility of 0.6 mg.kg-1 rocuronium being injected through a central venous catheter when a faster onset is needed. Due to wide differences in individual responses, monitoring of neuromuscular block is recommended.
Resumo:
The ulnar-to-median nerve anastomosis in the forearm is a very rare occurrence, not mentioned in many anatomical text books. We found only 4 cases cited in medical literature. Here we describe 2 new cases, for which diagnosis was suspected when the compound muscle action potential of the abductor pollicis brevis muscle (APB), obtained by maximal stimulation of the median nerve at the elbow, was lower than that obtained at the wrist. The diagnosis was confirmed by stimulation of the ulnar nerve at the elbow, which evoked a compound muscle action potential of the APB with a clear negative initial deflection without volume-conducted potential.
Resumo:
BACKGROUND AND OBJECTIVES: Before epídural steroids were used in chronic lumbar pain, subarachnoid injection of these agents was the treatment of choice. Although still preconized by some authors, this technique may lead to severe complications with neurological sequelae. This report aimed at describing a case of accidental subarachnoid injection of steroid associated to local anesthetics during epidural puncture to treat lumbar pain. CASE REPORT: Male patient, 46 years old, followed byneuro-surgery for presenting right sciatic pain for 9 month, refractory to clinical treatment due to L 4-L 5 disk protrusion confirmed by CT scan, without neurological deficit. Epidural puncture for pain treatment was performed in L 4-L 5 with 17G needle and 10 mL solution were injected containing 4 mL of 0.25% bupivacaine, 80 mg methylprednisolone and 4 mL of 0.9% saline. Although there has not been CSF reflux, 5 minutes after injection there were sensory block in T 4 and motor block in T 6, associated to blood pressure and heart rate decrease. CONCLUSIONS: Accidental subarachnoid injections with the association of steroids for pain relief may cause adverse effects. There are several risks, varying from mild transient symptoms to nervous injuries, including spinal cord injuries. Our patient had no sequelae from the accidental subarachnoid injection, probably because it has been a single injection.
Resumo:
In this work 3 new cases of suprascapular nerve mononeuropathy are described. ENMG diagnosis criteria were: a) normal sensory conduction studies of the ipsolateral ulnar, median and radial nerves; b) bilateral suprascapular nerve latencies with bilateral compound muscle action potential, obtained from the infraspinatus muscle with symmetrical techniques; and c) abnormal neurogenic infraspinatus muscle electromyographic findings, coexisting with normal electromyographical data of the ipsolateral deltoideus and supraspinatus muscles. These 3 cases of suprascapular mononeurpathy were found in 6,080 ENMG exams from our University Hospital. For us this mononeuropathy is rare with a 0.05% occurrence.
Resumo:
The effect of Microcurrent Electrical Nerve Stimulation (MENS) was evaluated and compared with occlusal splint therapy in temporomandibular disorders (TMD) patients with muscle pain. Twenty TMD patients were divided into four groups. One received occlusal splint therapy and MENS (I); other received splints and placebo MENS (II); the third, only MENS (III) and the last group, placebo MENS (IV). Sensitivity derived from muscle palpation was evaluated using a visual analogue scale. Results were submitted to analysis of variance (p<0.05). There was reduction of pain level in all groups: group I (occlusal splint and MENS) had a 47.7% reduction rate; group II (occlusal splint and placebo MENS), 66.7%; group III (MENS), 49.7% and group IV (placebo MENS), 16.5%. In spite of that, there was no statistical difference (analysis of variance / p<0.05) between MENS and occlusal splint therapy regarding muscle pain reduction in TMD patients after four weeks.
Resumo:
Zinc (Zn ++) has been shown as an important physiological inhibitor of pituitary PRL release, and Zn ++ and PRL could be involved in a negative feedback regulatory loop. However, this inhibitory effect has not been detected in humans with regard to thyrotropin releasing hormone (TRH), dopamine (DA) and histamine (HA) neurotransmitters. In order to investigate this topic, Zn ++ was acutely and chronically administered to five healthy men to observe the probable inhibitory effect on PRL release during insulin-induced hypoglycemia. The positive PRL response to hypoglycemia has generally been considered to be mediated via the hypothalamus by adrenergic, serotoninergic, histaminergic, opioid-peptidergic and TRH neurotransmitters. The results showed that Zn ++ was not able to inhibit the PRL release during insulin-induced hypoglycemia. Under these conditions, Zn ++ does not block hypothalamic neurotransmitters stimulated by hypoglycemia, thus excluding its clinical application in human beings. On the other hand, the effect of acute stress, such as hypoglycemia, on the serum Zn ++ profile was not observed. ©2006 Dustri-Verlag Dr. K. Feistle.
Resumo:
Purpose: We evaluated the somatic and autonomic innervation of the pelvic floor and rhabdosphincter before and after nerve sparing radical retropubic prostatectomy using neurophysiological tests and correlated findings with clinical parameters and urinary continence. Materials and Methods: From February 2003 to October 2005, 46 patients with prostate cancer were enrolled in a controlled, prospective study. Patients were evaluated before and 6 months after nerve sparing radical retropubic prostatectomy using the UCLA-PCI urinary function domain and neurophysiological tests, including somatosensory evoked potential, and the pudendo-urethral, pudendo-anal and urethro-anal reflexes. Clinical parameters and urinary continence were correlated with afferent and efferent innervation of the membranous urethra and pelvic floor. We used strict criteria to define urinary continence as complete dryness with no leakage at all, not requiring any pads or diapers and with a UCLA-PCI score of 500. Patients with a sporadic drop of leakage, requiring up to 1 pad daily, were defined as having occasional urinary leakage. Results: Two patients were excluded from study due to urethral stricture postoperatively. We evaluated 44 patients within 6 months after surgery. The pudendo-anal and pudendo-urethral reflexes were unchanged postoperatively (p = 0.93 and 0.09, respectively), demonstrating that afferent and efferent pudendal innervation to this pelvic region was not affected by the surgery. Autonomic afferent denervation of the membranous urethral mucosa was found in 34 patients (77.3%), as demonstrated by a postoperative increase in the urethro-anal reflex sensory threshold and urethro-anal reflex latency (p <0.001 and 0.0007, respectively). Six of the 44 patients used pads. One patient with more severe leakage required 3 pads daily and 23 showed urinary leakage, including 5 who needed 1 pad per day and 18 who did not wear pads. Afferent autonomic denervation at the membranous urethral mucosa was found in 91.7% of patients with urinary leakage. Of 10 patients with preserved urethro-anal reflex latency 80% were continent. Conclusions: Sensory and motor pudendal innervation to this specific pelvic region did not change after nerve sparing radical retropubic prostatectomy. Significant autonomic afferent denervation of the membranous urethral mucosa was present in most patients postoperatively. Impaired membranous urethral sensitivity seemed to be associated with urinary incontinence, particularly in patients with occasional urinary leakage. Damage to the afferent autonomic innervation may have a role in the continence mechanism after nerve sparing radical retropubic prostatectomy.
Resumo:
The objective of this study was to determine the mean distance between the infraorbital foramen and the infraorbital margin, as well as the mean distance between the infraorbital foramen and the piriform aperture on both sides of dry human skulls, with the aim of improving the efficiency in clinical situations, such as surgery and anesthetic procedures. Two hundred ninety-five skulls were used (590 sides), located in the Frankfurt Plane through a craniostat. The measurements were collected by two distinct operators, with a dry tip compass and carried to a caliper. The general mean obtained between the infraorbital foramen and the infraorbital margin was 6.37 mm (±1.69 mm), with a mean of 6,28 mm (±1.79 mm) on the right side and 6.45 mm (±1.76 mm) on the left side. The general mean obtained between the infraorbital foramen and the piriform aperture was 17.67 mm (±1.95 mm), being 17.75 mm (±2.10 mm) on the right side and 17.60 mm (±2.04 mm) on the left side. There were statistically significant differences between the right and left distances of the infraorbital foramen and the infraorbital margin, verified by the Student's-t test. The results of this study allow a more precise location of the infraorbital foramen, particularly as regards the infraorbital margin, since this distance is of relevant importance as a repair point during surgical procedures involving this anatomical structure.
Resumo:
Introduction: Impacted knife injuries in the maxillofacial region are rare and infrequently reported. In cases of injury involving orbit or eye, these reports are even rarer. Discussion: Damage to the orbital contents may result in a rupture of the globe, extraocular muscle injury, lacrimal gland damage, and others. Orbital foreign bodies are not only difficult to detect, and clinical features vary according to its size, characteristics, shape, penetrating method, and site. In this report, a case of abducens nerve palsy after orbitoethmoidal knife injury is presented. © 2010 Springer-Verlag.
Resumo:
The association of unilateral trochlear nerve palsy with Claude Bernard-Horner syndrome represents a rare clinical condition. We present the case of a patient with this unusual presentation. The investigation performed implicated cerebrovascular disease as the underlying cause of the condition in this patient. © 2011 S. Karger AG, Basel.
Resumo:
The texture of concrete blocks is very important and is often the decisive factor when choosing a product, particularly if the building specifications call for high-strength blocks allied to low-cost finish, in which case exposed blocks with a closer texture are often preferred. Furthermore, a closer texture, especially for exteriors, may be a vital factor in ensuring the building's durability. At present, however, there is no standard to quantify the texture of a structural block. Further, when studying masonry blocks compressive strength should never be overlooked. This article discusses a procedure to produce concrete block textures with and without the addition of lime, but still to achieve the required compressive strength. The method used in this study, to evaluate texture, proved to be simpler and cheaper than methods reported by other authors in the literature. The addition of small quantities of lime proved beneficial for both texture and compressive strength. Increasing the amount of lime further, however, only improved texture.
Resumo:
Understanding the biological activity profile of the snake venom components is fundamental for improving the treatment of snakebite envenomings and may also contribute for the development of new potential therapeutic agents. In this work, we tested the effects of BthTX-I, a Lys49 PLA2 homologue from the Bothrops jararacussu snake venom. While this toxin induces conspicuous myonecrosis by a catalytically independent mechanism, a series of in vitro studies support the hypothesis that BthTX-I might also exert a neuromuscular blocking activity due to its ability to alter the integrity of muscle cell membranes. To gain insight into the mechanisms of this inhibitory neuromuscular effect, for the first time, the influence of BthTX-I on nerve-evoked ACh release was directly quantified by radiochemical and real-time video-microscopy methods. Our results show that the neuromuscular blockade produced by in vitro exposure to BthTX-I (1 μM) results from the summation of both pre- and postsynaptic effects. Modifications affecting the presynaptic apparatus were revealed by the significant reduction of nerve-evoked [3H]-ACh release; real-time measurements of transmitter exocytosis using the FM4-64 fluorescent dye fully supported radiochemical data. The postsynaptic effect of BthTX-I was characterized by typical histological alterations in the architecture of skeletal muscle fibers, increase in the outflow of the intracellular lactate dehydrogenase enzyme and progressive depolarization of the muscle resting membrane potential. In conclusion, these findings suggest that the neuromuscular blockade produced by BthTX-I results from transient depolarization of skeletal muscle fibers, consequent to its general membrane-destabilizing effect, and subsequent decrease of evoked ACh release from motor nerve terminals. © 2012 Elsevier Ltd.
Resumo:
Objectives: To compare autogenous bone (AT) and fresh-frozen allogeneic bone (AL) in terms of histomorphometrical graft incorporation and implant osseointegration after grafting for lateral ridge augmentation in humans. Materials and methods: Thirty-four patients were treated with either AL (20 patients) or AT (14 patients) onlay grafts. During implant installation surgery 6 months after grafting, cylindrical biopsies were harvested perpendicularly to the lateral aspect of the augmented alveolar ridge. Additionally, titanium mini-implants were installed in the grafted regions, also perpendicularly to the ridge; these were biopsied during second-stage surgery. Histological/histomorphometric analysis was performed using decalcified and non-decalcified sections. Results: Histological analysis revealed areas of necrotic bone (NcB) occasionally in contact with or completely engulfed by newly formed vital bone (VB) in both AT and AL groups (55.9 ± 27.6 vs. 43.1 ± 20.3, respectively; P = 0.19). Statistically significant larger amounts of VB (27.6 ± 17.5 vs. 8.4 ± 4.9, respectively; P = 0.0002) and less soft connective tissue (ST) (16.4 ± 15.6 vs. 48.4 ± 18.1, respectively; P ≤ 0.0001) were seen for AT compared with AL. No significant differences were observed between the groups regarding both bone-to-implant contact (BIC) and the bone area between implant threads (BA) on the mini-implant biopsies. Conclusion: Allogeneic bone block grafts may be an option in cases where a limited amount of augmentation is needed, and the future implant can be expected confined within the inner aspect of the bone block. However, the clinical impact of the relatively poor graft incorporation on the long-term performance of oral implants placed in AL grafts remains obscure. © 2013 John Wiley & Sons A/S.