274 resultados para Muscular torque


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical approach for the spin stabilized satellite attitude propagation is presented using the non-singular canonical variables to describe the rotational motion. Two sets of variables were introduced for Fukushima in 1994 by a canonical transformation and they are useful when the angle between z-satellite axis of a coordinate system fixed in artificial satellite and the rotational angular momentum vector is zero or when the angle between Z-equatorial axis and rotation angular momentum vector is zero. Analytical solutions for rotational motion equations and torque-free motion are discussed in terms of the elliptic functions and by the application of some simplification to get an approximated solution. These solutions are compared with a numerical solution and the results show a good agreement for many rotation periods. When the mean Hamiltonian associated with the gravity gradient torque is included, an analytical solution is obtained by the application of the successive approximations' method for the satellite in an elliptical orbit. These solutions show that the magnitude of the rotation angular moment is not affected by the gravity gradient torque but this torque causes linear and periodic variations in the angular variables, long and short periodic variations in Z-equatorial component of the rotation angular moment and short periodic variations in x-satellite component of the rotation angular moment. The goal of this analysis is to emphasize the geometrical and physical meaning of the non-singular variables and to validate the approximated analytical solution for the rotational motion without elliptic functions for a non-symmetrical satellite. The analysis can be applied for spin stabilized satellite and in this case the general solution and the approximated solution are coincidence. Then the results can be used in analysis of the space mission of the Brazilian Satellites. (C) 2007 COSPAR. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine the accuracy of mechanical torque devices in delivering target torque values in dental offices in Salvador, Brazil. A team of researchers visited 16 dental offices, and the clinicians applied torque values (20 and 32 Ncm) to electronic torque controllers. Five repetitions were completed at each torque value and data were collected. When 20 Ncm of torque was used, 62.5% of measured values were accurate (within 10% of the target value). For 32 Ncm, however, only 37.5% of these values were achieved. Several of the tested mechanical torque devices were inaccurate. Int J Prosthodont 2011;24:38-39.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The aim of this study was to compare intrapulpal temperature increases produced by a high-speed high-torque (speed-increasing) handpiece, a high-speed low-torque handpiece (air-turbine) and an Er: YAG (Erbium: Yttrium-Aluminum-Garnet) laser. Subject and methods Thirty bovine incisors were reduced to a dentine thickness of 2.0 mm. Class V preparations were prepared to a depth of 1.5 mm, measured with a caliper or by a mark on the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (C). Analysis was performed on the following groups (n = 10) treated with: G1, low-torque handpiece; G2, high-torque handpiece; and G3, Er: YAG laser (2.94 mu m at 250 mJ/4 Hz), all with water cooling. The temperature increases were recorded with a computer linked to the thermocouples. Results The data were submitted to ANOVA and Tukey statistical test. The average temperature rises were: 1.92 +/- 0.80 degrees C for G1, 1.34 +/- 0.86 degrees C for G2, and 0.75 +/- 0.39 degrees C for G3. There were significant statistical differences among the groups (p = 0.095). All the groups tested did not have a change of temperature that exceeds the threshold of 5.5 degrees C. Conclusion Temperature response to the low and high torque handpieces seemed to be similar, however the Er: YAG laser generated a lower temperature rise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a canonical formulation, the stability of the rotational motion of artificial satellites is analyzed considering perturbations due to the gravity gradient torque. Here Andoyer's variables are used to describe the rotational motion. One of the approaches that allow the analysis of the stability of Hamiltonian systems needs the reduction of the Hamiltonian to a normal form. Firstly equilibrium points are found. Using generalized coordinates, the Hamiltonian is expanded in the neighborhood of the linearly stable equilibrium points. In a next step a canonical linear transformation is used to diagonalize the matrix associated to the linear part of the system. The quadratic part of the Hamiltonian is normalized. Based in a Lie-Hori algorithm a semi-analytic process for normalization is applied and the Hamiltonian is normalized up to the fourth order. Once the Hamiltonian is normalized up to order four, the analysis of stability of the equilibrium point is performed using the theorem of Kovalev and Savichenko. This semi-analytical approach was applied considering some data sets of hypothetical satellites. For the considered satellites it was observed few cases of stable motion. This work contributes for space missions where the maintenance of spacecraft attitude stability is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Comparar a atividade muscular antes e após o contato com o solo entre as aterrissagens unilateral (AU) e bilateral (AB) em atletas do sexo masculino. PARTICIPANTES: Quinze atletas masculinos de voleibol sem sinais e sintomas de lesões nas extremidades inferiores (13 ± 1 ano, 1,70 ± 0,12m, 60 ± 12kg). MENSURAÇÕES:Os participantes realizaram dois saltos verticais, aterrissando unilateralmente e bilateralmente. A atividade mioelétrica do reto femoral (RF), bíceps femoral (BF), adutores de quadril (AQ) e a relação BF/RF foram comparados entre as duas aterrissagens e entre as fases caracterizadas por 100ms antes (PRE) e 100ms após (POS) o contato com o solo. RESULTADOS: Em ambas as aterrissagens, a ativação do RF foi maior na fase POS em relação à PRE. Na comparação entre as aterrissagens dentro da mesma fase não encontramos diferenças estatísticas. Apesar de o BF não ter apresentado diferenças entre as fases PRE e POS em cada aterrissagem, sua ativação foi maior na AU. Os AQ apresentaram maior ativação na fase POS durante a AU, no entanto não houve diferenças quando comparadas as duas aterrissagens. A relação BF/RF apresentou valores maiores em ambas as aterrissagens na fase PRE. No entanto, não encontramos diferenças entre as aterrissagens. CONCLUSÃO: Os resultados sugerem que cada músculo apresenta um papel diferente durante a fase de aterrissagem em homens. Enquanto que o RF possui como principal função a frenagem da articulação do joelho e do movimento descendente, caracterizada pelo aumento da ativação na fase pós-contato, o BF parece atenuar a tensão articular do joelho em atividades de maior impacto, mantendo-se mais ativo durante todo o ciclo da AU. Já a maior ativação dos AQ após o contato com solo na AU evidencia a importância da região lombo-pélvica na estabilização pélvica em situações de grande instabilidade. Estudos futuros são necessários para determinar os efeitos da ativação muscular apresentada na imposição de cargas mecânicas potencialmente lesivas no joelho em atletas do sexo masculino.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of anthropometric measurements of triceps (TSF) and subscapular skinfolds (SSF) and mid-upper arm muscle circumference (MAMC) was examined as far as the diagnosis of energy-protein malnutrition (EPM) is concerned. The study was undertaken in five groups of patients (n = 231): arterial hypertension (AH, n = 63), chronic obstructive pulmonary disease (COPD, n = 17), hemodialyzed chronic renal failure (CRF, n = 19), critically ill patients with an acute event (CA, n = 42) and critically ill patients with chronic diseases (CCD, n = 90). The results were compared to those obtained in a group of healthy individuals (control group, n = 102). The control group and the group of patients were allocated in subgroups according to sex and age (less than 50 and more than 50 years). It was expected that significant differences would be found for the anthropometric values between the control subgroups and the COPD, the CRF and the CCD subgroups of patients. For the skinfold thicknesses (TSF and SSF), significant differences were found between CRF, CCD subgroups and the control subgroups under fifty years of age; however, the differences were not significant when the subgroups over fifty were analyzed. Concerning the MAMC, significant differences were found: 1 degree) between the CRF subgroups (males and females) and the control subgroups under fifty years of age; 2 degrees) between the CCD male subgroups (younger and older subgroups) and the respective control subgroups and 3 degrees) between the COPD and the control subgroups.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A semi-analytical approach is proposed to study the rotational motion of an artificial satellite under the influence of the torque due to the solar radiation pressure and taking into account the influence of Earth's shadow. The Earth's shadow is introduced in the equations for the rotational motion as a function depending on the longitude of the Sun, on the ecliptic's obliquity and on the orbital parameters of the satellite. By mapping and computing this function, we can get the periods in which the satellite is not illuminated and the torque due to the solar radiation pressure is zero. When the satellite is illuminated, a known analytical solution is used to predict the satellite's attitude. This analytical solution is expressed in terms of Andoyer's variables and depends on the physical and geometrical properties of the satellite and on the direction of the Sun radiation flux. By simulating a hypothetical circular cylindrical type satellite, an example is exhibited and the results agree quite well when compared with a numerical integration. © 1997 COSPAR. Published by Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To identify the electromyographic fatigue threshold in the erector spinae muscle. Methods: Eight 19 to 24-year-old male volunteers participated in this study, in which surface electrodes were used, as well as a biological signals acquisition module (Lynx) with a sampling frequency of 1000Hz, a 1000 times gain, a 20Hz high pass filter and a 500Hz low pass filter. The test consisted of repeated isometric contractions of the erector spinae muscle in a 45° hip flexion posture, with 30%, 40%, 50% and 60% of the maximum voluntary isometric contraction. Results: A positive correlation of the RMS (root mean square) value as a function of time was found for most of the subjects with 40% (N = 6), 50% (N = 7) and 60% (N = 8) loads of the maximum voluntary isometric contraction. Conclusions: It was concluded, from this study, that the proposed protocol provides evidence, through the electromyographic signal, of the development of fatigue in the erector spinae muscle with loads of 40%, 50% and 60% of the maximum voluntary isometric contraction. The protocol also allows the electromyographic fatigue threshold and its probable applicability in the diagnosis of this phenomenon during repetitive activities to be determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to analyze the relationship of maximal aerobic power and the muscular strength (maximal isotonic strength and vertical jump explosive power) with the running economy (RE) in endurance athletes. Twenty-six male runners (27.9 ± 6.4 years; 62.7 ± 4.3 kg; 168.6 ± 6.1 cm; 6.6 ± 3.1% of body fat) performed in different days the following tests: a) incremental test to determine the maximal oxygen uptake (V̇O2max) and the intensity corresponding to the V̇O2max (IV̇O2max); b) constant-velocity treadmill run to determine RE; c) 1-RM test in the leg press and; d) maximal vertical jump test (VJ). V̇O2max (63.8 ± 8.3 ml/kg/min) was significantly correlated (r = 0.63; p < 0.05) with RE (48.0 ± 6.6 ml/kg/min). However, the IV̇O2max (18.7 ± 1.1 km/h), the maximal isotonic strength (230.3 ± 41.2 kg) and the VJ (30.8 ± 3.8 cm) were not significantly correlated with RE. One concludes that the maximal aerobic power can explain in part the inter-individual RE variability in endurance athletes. However, maximal isotonic strength and explosive strength seem not to be associated with RE values observed in this group of athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since Ranzini suggested supplementing the SPT test with measurement of the torque required to turn the split spoon sampler after driving, many Brazilian engineers have been using this in the design of pile foundations. This paper presents a study of the rod length influence in the torque measurement. A theoretical study of material resistance considering torsion and bending in a thin wall tubular steel shaft was performed. It makes possible to conclude that the shearing tension caused by the proper weight represents less than 1% of the shearing tension caused by the turning moment. In addition, an experimental study was done with electric torquemeters fixed in a horizontal rod system. The tests were being carried out to analyze rods of one meter to twenty meters in length and the measurements were collected at the ends of each rod length verifying the efficiency data. As a result, it is possible to verify that the torque difference through rod length is lower than minimum scales of mechanical torquemeters that are used on practical engineering. Also a fact to be considered is a big torque loss for values under 20 N.m of applied torque. This way, the SPT-T is not adequate to low consistency soil. Copyright ASCE 2007.