93 resultados para Malón de Chaide, 1530-1589.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents three different numerical models for the evaluation of the stresses in corrugated sheets under bending. Regarding the numerical simulations different approaches can be considered, i.e., a elastic linear analysis or a physical nonlinear analysis, that considers criteria to fail for the sheet material. Moreover, the construction of the finite element mesh can be used shell elements or solid elements. The choice of each finite element must be made from the consideration of their representativity before behavior to be simulated. Thus, the numerical modelling in this manuscript was performed from the three-dimensional models using the SAP2000Nonlinear software, version 7.42, which has as base the finite elements method (FEM). It was considered shell elements in the build the mesh of finite elements and an analysis of type elastic linear in this case. Five mm thick sheets were evaluated considering three different longitudinal dimensions (spans), i.e., 1100 mm, 1530 mm and 1830 mm. The applied load to the models was 2500 N/m and it was verified that the spans of support of sheets have a significant influence on the results of stresses. The sheets with larger spans present larger stresses for the same applied load. The most intense values of tension occur in the troughs (low waves) of the sheets, on the lower surface, while the most intense values of compression occur in the crests (high waves), on the upper surface of the sheet. The flanks, which are the parts among the troughs and crests of the sheets, are submitted to low levels of stresses. The numeric results of the stresses showed a good agreement with the results obtained from other researchers(3) and these results can be used to predict the behavior of corrugated sheets under bending.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report, for the first time to our knowledge, experimental results on pedestal waveguides produced with Yb3+/Er3+ codoped Bi2O3-WO3-TeO2 thin films deposited by RF Sputtering for photonic applications. Thin films were deposited using Ar/O-2 plasma at 5 mTorr pressure and RF power of 40 W on substrates of silicon wafers. The definition of the pedestal waveguide structure was made using conventional optical lithography followed by plasma etching. Propagation losses around 2.0 dB/cm and 2.5 dB/cm were obtained at 633 and 1050 nm, respectively, for waveguides in the 20-100 mu m width range. Single-mode propagation was measured for waveguides width up to 10 mu m and 12 mu m, at 633 nm and 1050 nm, respectively; for larger waveguides widths multi-mode propagation was obtained. Internal gain of 5.6 dB at 1530 nm, under 980 nm excitation, was measured for 1.5 cm waveguide length (similar to 3.7 dB/cm). The present results show the possibility of using Yb3+/Er3+ codoped Bi2O3-WO3-TeO2 pedestal waveguide for optical amplifiers. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to examine tapping synchronization in children with and without Developmental Coordination Disorder (DCD). Participants were 27 children from which 13 diagnosed with motor difficulties composed the DCD group and 14 children with typical development (TD) the comparison group. The experimental task consisted of performing 25 continuous tapping on a surface of an electronic drum with the preferred hand. Participants were required to tap in synchrony with an auditory bip generated by customized software. Three interval values the tapping task were tested: 470 ms, 1000 ms, 1530 ms. The dependent variables were constant error (CE) and absolute error (AE) and standard deviation of absolute error (SD of AE). The ANOVA 2 x 3 x 3 (Group X Age x Interval) with repeated measures in the last factor for the CE indicated significant interaction among Group X Age X Interval. For the AE and SD of AE the ANOVAs yielded significant main effect of Interval and a significant interaction between Group X Interval. The results of the present study indicated that children with DCD were less accurate and more variable in the tapping synchronization than children with TD. Differences in performance between DCD and children with TD become larger as the interval of the auditory signal increases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This manuscript describes the use of a tooth indicated for extraction due
to orthodontic reasons as an anchorage aid to receive undesirable side effects caused by orthodontic uprighting of a contralateral molar tooth. The mandibular right second molar was mesially tipped as a result of loss of the adjacent first molar. Since the treatment plan involved extraction of the mandibular left first premolar, undesirable side effects associated with the molar uprighting movement were transferred to this tooth. Once the second molar was vertical, the premolar was extracted and the treatment continued. The results suggest that treatment time can be reduced if undesirable orthodontic mechanical side effects can be directed to a tooth whose extraction is indicated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When a T-loop is used in segmental mechanics, it is generally attached posteriorly to an auxiliary tube in the first molars and anteriorly to a crimpable cross tube or a Burstone canine bracket. This article illustrates the use of a crimpable tube with a 90-degree bend on the base wire to secure a T-loop in segmental retraction. Both of these approaches allow a T-loop to be reactivated in a simple manner without undesirable changes in the system of forces, which could happen if the T-loop is skewed posteriorly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[Purpose] Sit-to-walk performance is linked to proper proprioceptive information processing. Therefore, it is believed that an increase of proprioceptive inflow (using muscle vibration) might improve sit-to-walk performance. However, before testing muscle vibration effects on a frail population, assessment of its effects on healthy young people is necessary. Thus, the aim of this study was to investigate the effects of muscle vibration on sit-to-walk performance in healthy young adults. [Subjects and Methods] Fifteen young adults performed the sit-to-walk task under three conditions: without vibration, with vibration applied before movement onset, and with vibration applied during the movement. Vibration was applied bilaterally for 30 s to the tibialis anterior, rectus femoris, and upper trapezius muscles bellies. The vibration parameters were as follows: 120 Hz and 1.2 mm. Kinematics and kinetic data were assessed using a 3D motion capture system and two force plates. The coordinates of reflective markers were used to define the center-of-mass velocities and displacements. In addition, the first step spatiotemporal variables were assessed. [Results] No vibration effect was observed on any dependent variables. [Conclusion] The results show that stimulation of the proprioceptive system with local muscle vibration does not improve sit-towalk performance in healthy young adults.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the efficacy of minutia-based fingerprint matching techniques for good-quality images captured by optical sensors, minutia-based techniques do not often perform so well on poor-quality images or fingerprint images captured by small solid-state sensors. Solid-state fingerprint sensors are being increasingly deployed in a wide range of applications for user authentication purposes. Therefore, it is necessary to develop new fingerprint-matching techniques that utilize other features to deal with fingerprint images captured by solid-state sensors. This paper presents a new fingerprint matching technique based on fingerprint ridge features. This technique was assessed on the MSU-VERIDICOM database, which consists of fingerprint impressions obtained from 160 users (4 impressions per finger) using a solid-state sensor. The combination of ridge-based matching scores computed by the proposed ridge-based technique with minutia-based matching scores leads to a reduction of the false non-match rate by approximately 1.7% at a false match rate of 0.1%. © 2005 IEEE.