89 resultados para Low cost piezoelectric sensor
Resumo:
The use of physical characteristics for human identification is known as biometrics. Among the many biometrics traits available, the fingerprint is the most widely used. The fingerprint identification is based on the impression patterns, as the pattern of ridges and minutiae, characteristics of first and second levels respectively. The current identification systems use these two levels of fingerprint features due to the low cost of the sensors. However, the recent advances in sensor technology, became possible to use third level features present within the ridges, such as the perspiration pores. Recent studies show that the use of third-level features can increase security and fraud protection in biometric systems, since they are difficult to reproduce. In addition, recent researches have also focused on multibiometrics recognition due to its many advantages. The goal of this research project was to apply fusion techniques for fingerprint recognition in order to combine minutia, ridges and pore-based methods and, thus, provide more robust biometrics recognition systems, and also to develop an automated fingerprint identification system using these three methods of recognition. We evaluated isotropic-based and adaptive-based automatic pore extraction methods, and the fusion of pore-based method with the identification methods based on minutiae and ridges. The experiments were performed on the public database PolyUHRF and showed a reduction of approximately 16% in the EER compared to the best results obtained by the methods individually
Resumo:
The gastrointestinal tract is the main route of nutrients absorption and drugs delivery. Is important to know the parameters related to the tract, like gastric emptying and gastrointestinal transit, in order to better understand the behavior of different kind of meals or drugs passing through the GIT. Many techniques are used to study these parameters, such as manometry, scintigraphy, phenol red, activated charcoal and carbon-13 reading. However, these methods use radiation, are invasive and require animal sacrifice. As an alternative proposal, the Alternate Current Biosusceptometry (ACB), a magnetic technique, has proved to be effective for these studies with small animals, in a noninvasive way, low cost, radiation free and avoiding the animal death. Associating the ACB to magnetic micro or nanoparticles used as tracers, it is possible to observe the meal behavior inside of the GIT. Focusing meanly on liquid meals digestion, this paper had the objective to evaluate the efficiency of the ACB technique in gastric emptying and gastrointestinal transit evaluation of liquid meals in rats. To perform the experiments, magnetic nanoparticles (ferrite, MgFe2O4) were used on a 1,5 ml solution introduced by gavage on similar weight and age rats. The sensor made by 2 pairs of coils, capable of generating and detecting magnetic fields, creates a field on the interest place and when this field is in contact with the marked meal, it changes, resulting on a variation of the measured voltage. The voltage variation is analyzed and is obtained a particle concentration on the interest region. The results showed that is possible to apply the ACB technique on the GIT evaluation of liquid particles digestion, gastric emptying and meal cecum arrival time curves were obtained and from that, is possible to observe a pattern of gastrointestinal transit. Both mean process time values were acquired, proving the technique capability of ...
Resumo:
This monograph proposes the implementation of a low cost PID controller utilizing a PIC microcontroller, and its application in a positioning system previously controlled by a dedicated integrated circuit for a positioning system. Applying the closed-loop PID control, the system instability was reduced, and its response was smoother, eliminating vibrations and mechanical wear compared to its response with the dedicated integrated circuit, which has a very limited control action. The actuator of the system is a DC motor, whose speed is controlled by the Pulse Width Modulation (PWM) technique, using a Full-Bridge circuit, allowing the shift of direction of rotation. The utilized microcontroller was the PIC16F684, which has an enhanced PWM module, with its analog converters used as reference and position feedback. The positioning sensor is a multiturn potentiometer coupled to the motor axis by gears. The possibility of programming the PID coefficients in the microcontroller, as well as the adjustment of the sampling rate, allows the implemented system achieving high level of versatility
Resumo:
The present work develops a residential automation system controlled by PIC microcontroller connected to a domestic network using the TCP/IP protocol. This was motivated by the viability of building an automation system to control basic elements of a house with low cost, which cannot be found nowadays. Initially is presented a brief history of the automation systems and an introduction about PIC microcontrollers. Afterwards is presented an overview of the system to be implemented. Then it is shown a suggested circuit and the sensor and actuator elements as well as the software to manage the system, this was all build and test in the laboratory. In the end are the results obtained from the prototype, like the energy consumption, the cost, efficiency and reliability
Resumo:
Objective: This article describes the application and the performance of a cheap, simple and portable device that can be used for colorimetric quantitative determination of captopril (CPT) in pharmaceutical preparations. Methods: The sensor is a light detector resistor (LDR) placed into a black PTFE cell and coupled to a low cost multimeter (Ohmmeter). The instrument has been tested and is easy and fast to use. The quantitative study is based mainly on reduction of ammonium molybdate by captopril, in the presence of sulphuric acid, producing a green-yellow compound (max 407 nm). The calibration curves were obtained by plotting the electric resistance of the LDR against the CPT concentration on the range of 4.60 x 10-4 to 1.84 x 10-3 mol l-1 with a good coefficient of determination (R2 = 0.9962). Results: Statistical analysis of the obtained results showed no significant difference between the proposed methodology and the official reported method as evident from the t-test and variance ratio at 95% confidence level. Conclusion: The results of this study demonstrate that the instrument can be used for simple, accurate, precise, fast, in situ and low-cost colorimetric analysis of captopril in pharmaceuticals products.
Resumo:
Pós-graduação em Desenvolvimento Humano e Tecnologias - IBRC
Resumo:
Pós-graduação em Ciência da Computação - IBILCE
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This work proposes the use of a simple voltage divider circuit composed by one potentiometer and one resistor to simulate the behavior of the electrical output signal of linear and nonlinear sensors. It is a low cost way to implement practical experiments in classroom and it also enables the analysis of interesting topics of electricity. This work induces naturally to a class guide where students can build and characterize a voltage divider to explore several concepts about sensors output signal. As the result of this teaching activity it is expected that students understand fundamentals of voltage divider, potentiometer operation, fundamental sensor characteristics, transfer function, and, besides, associate directly concepts of physics and mathematics with a practical approach.
Resumo:
Solar heaters are an appropriate technology in tropical and sub-tropical climates to heat bath water by solar energy. Low-cost solar heaters meet the demand of low-income rural communities which currently do not have access to this technology. Current research analyzes the economic viability of solar heaters, built with recyclable materials, to reduce electric energy bill. A solar heating system was built consisting of recyclable materials in accordance with the manuals provided by the Secretariat of Environment of the state of Paraná (SEMA). Duration of use of electric showers by families of rural properties was determined to calculate expenses and billing of electricity. Simulation and material costs showed that the system was feasible. Commercial solar heaters could be replaced at a cost of R$ 22.61 per month during 13 months.
Resumo:
This work focuses basically on the design and analysis of simple and low cost hardware systems efficiency for temperature measurement in agricultural area. The main objective is to prove quantitatively, through statistical data analysis, to what extent a simple hardware designed with inexpensive components can be used safely in the indoor temperature measurement in farm buildings, such as greenhouses, warehouse or silos. To verify the of simple hardware efficiency, its data were compared with data from measurements with a high performance LabVIEW platform. This work proved that a simple hardware based on a microcontroller and the LM35 sensor can perform well. It presented a good accuracy but a relatively low precision that can be improved when performed some consecutive signal sampling and then used its average value. Although there are many papers that explain these components, this work has the distinction of presenting a data analysis in numerical form and using high performance systems to ensure critical data comparison.