102 resultados para LIDAR (light detection and ranging)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phenotypic and genotypic SPM and IMP metallo-beta-lactamases (MBL) detection and also the determination of minimal inhibitory concentrations (MIC) to imipenem, meropenem and ceftazidime were evaluated in 47 multidrug-resistant Pseudomonas aeruginosa isolates from clinical specimens. Polymerase chain reaction detected 14 positive samples to either bla(SPM) or bla(IMP) genes, while the best phenotypic assay (ceftazidime substrate and mercaptopropionic acid inhibitor) detected 13 of these samples. Imipenem, meropenem and ceftazidime MICs were higher for MBL positive compared to MBL negative isolates. We describe here the SPM and IMP MBL findings in clinical specimens of P. aeruginosa from the University Hospital of Botucatu Medical School, São Paulo, Brazil, that reinforce local studies showing the high spreading of bla(SPM) and bla(IMP) genes among Brazilian clinical isolates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives:The aim of this in vitro study was to assess the inter- and intra-examiner reproducibility and the accuracy of the International Caries Detection and Assessment System-II (ICDAS-II) in detecting occlusal caries.Methods:One hundred and sixty-three molars were independently assessed twice by two experienced dentists using the 0- to 6-graded ICDAS-II. The teeth were histologically prepared and classified using two different histological systems [Ekstrand et al. (1997) Caries Research vol. 31, pp. 224-231; Lussi et al. (1999) Caries Research vol. 33, pp. 261-266] and assessed for caries extension. Sensitivity, specificity, accuracy and area under the ROC curve (A(z)) were obtained at D(2) and D(3) thresholds. Unweighted kappa coefficient was used to assess inter- and intra-examiner reproducibility.Results:For the Ekstrand et al. histological classification the sensitivity was 0.99 and 1.00, specificity 1.00 and 0.69 and accuracy 0.99 and 0.76 at D(2) and D(3), respectively. For the Lussi et al. histological classification the sensitivity was 0.91 and 0.75, specificity 0.47 and 0.62 and accuracy 0.86 and 0.68 at D(2) and D(3), respectively. The A(z) varied from 0.54 to 0.73. The inter- and intra-examiner kappa values were 0.51 and 0.58, respectively.Conclusions:ICDAS-II presented good reproducibility and accuracy in detecting occlusal caries, especially caries lesions in the outer half of the enamel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Malva sylvestris é comumente confundida com Pelargonium graveolens e Pelargonium odoratissimum devido às semelhanças na morfologia foliar. As folhas de M. sylvestris possuem antocianinas com propriedades citotóxicas, antiinflamatória, antitumoral e antioxidante já comprovadas cientificamente. As folhas de P. odoratissimum apresentam óleo essencial com propriedades antibacteriana e espasmolítica, e o óleo essencial da folha de P. graveolens possui atividade antimicrobiana e antifúngica. O objetivo deste estudo foi analisar morfo-anatomicamente as folhas destas espécies, apontando diferenças que possam ser utilizadas para esclarecer controvérsias na sua utilização como planta medicinal. Com a finalidade de se comparar anatomicamente a estrutura de cada planta, as amostras foram observadas por Microscopia de Luz e Microscopia Eletrônica de Varredura (MEV). A anatomia foliar entre as espécies foi bem distinta. Malva sylvestris apresentou tricomas do tipo capitado, estrelado e tector, além de drusas e células mucilaginosas. A distinção entre P. graveolens e P. odoratissimum foi observada em relação aos tricomas. Ambas as espécies apresentaram tricomas glandulares e tectores, sendo que P. graveolens se diferencia pela maior altura dos tricomas tectores e menor quantidade destes em relação ao P. odoratissimum. Este trabalho permitiu constatar diferenças anatômicas, auxiliando na taxonomia e classificação entre estas espécies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective-To develop and apply the liquid-phase blocking sandwich ELISA (BLOCKING-ELISA) for the quantification of antibodies against foot-and-mouth disease virus (FMDV) strains O-1 Campos, A(24) Cruzeiro, and C-3 Indaial.Design-Antibody quantification.Sample Population-158 water buffalo from various premises of São Paulo Stale-Brazil. The sera were collected either from systemically vaccinated or nonvaccinated animals.Procedure-The basic reagents of BLOCKING-ELISA (capture and detector antibodies, virus antigens, and conjugate) were prepared and the reaction was optimized and standardized to quantify water buffalo antibodies against FMDV. An alternative procedure based on mathematical interpolation was adopted to estimate more precisely the antibody 50% competition liters in the BLOCKING-ELISA. These titers were compared with the virus-neutralization test (VNT) titers to determine the correlation between these techniques. The percentages of agreement, cutoff points, and reproducibility also were determined.Results-The antibody liters obtained in the BLOCKING-ELISA had high positive correlation coefficients with VNT, reaching values of 0.90 for O-1 Campos and C-3 Indaial, and 0.82 for the A(24) Cruzeiro (P < 0.0005). The cutoff points obtained by use of the copositivity and conegativity curves allowed determination of high levels of agreement between BLOCKLNG-ELISA and VNT antibody titers against the 3 FMDV strains analyzed.Conclusions-The results characterized by high cor relation coefficients, levels of agreement, and reproducibility indicate that the BLOCKING-ELISA may replace the conventional VNT for detection and quantification of antibodies from water buffalo sera to FMDV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diabetes mellitus can lead to reproductive disorders that in turn result in weakened fertility brought about by morphofunctional changes in the testes and accessory sex glands. However, doubts persist concerning the basic biology of the secretory epithelial cells and the stroma of the coagulating gland of diabetic mice. Thus, the objective of the present study was to analyze the histological and ultrastructural changes associated with stereology of the coagulating gland of mice with alloxan-induced diabetes, and of spontaneously diabetic mice. Sixteen mice of the C57BL/6J strain, and eight non-obese diabetic (NOD) mice were used. The animals were divided into three groups: 1) control (C), 2) alloxan diabetic (AD), and 3) NOD. Thirty days after the detection of diabetic status in group 2, all of the animals were killed and then perfused with Karnovsky's solution through the left cardiac ventricle. The coagulating gland was then removed and processed for morphometric study by light microscopy and electron microscopy. The results showed thickening of the stroma, atrophy of secretory epithelial cells, and disorganization of the organelles involved in the secretory process in both NOD and alloxan-induced mice. Thus, it may be concluded that the coagulating gland suffered drastic morphological changes, and consequently impaired glandular function, in the presence of diabetes mellitus type I in both NOD and AD mice. (C) 2003 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report optical gain at 382 and 414 nm from Nd3+-doped fluroindate glasses after excitation with lasers operating either at 583 or 532 nm. Stimulated emission due to a frequency upconversion process results in increase of the emitted violet and blue light intensity and emission line narrowing. Large optical gain is measured by pump-probe spectroscopy using samples with various Nd3+ concentrations. © 1999 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work uses a monitoring system based on a PC platform, where the acoustic emission and electric power signals generated during the grinding process are used to investigate superficial burning occurrence in a surface grinding operation using two types of steel, three grinding conditions and an Al203 vitrified grinding wheel. Acoustic emission signals on the workpiece and grinding power were measured during a surface plunge operation until the grinding burn happened. From the results the standard deviation of the acoustic emission signal and the maximum electric power were calculated for each grinding pass. The proposed DPO parameter is the product between the power level and acoustic emission standard deviation. The results show that both signals can be used for burning detection, and the parameter DPO is the best indicator for the burning studied in this work. This can be explained by the high dispersion of the acoustic emission RMS level associated to the high power consumption when the grinding wheel lose its sharpness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work it was developed a procedure for the determination of vanadium in urine samples by electrothermal atomic absorption spectrometry using successive injections for preconcentration into a preheated graphite tube. Three 60 μL volumes were sequentially injected into the atomizer preheated to a temperature of 110°C. Drying and pyrolysis steps were carried out after each injection. A chemical modifier, barium difluoride (100 mg L-1), and a surfactant, Triton X-100 (0.3% v v-1), were added to the urine sample. When injecting into a hot graphite tube, the sample flow-rate was 0.5 μL s-1. The limits of detection and quantification were 0.54 and 1.82 without preconcentration, and 0.11 and 0.37 μg L-1 with preconcentration, respectively. The accuracy of the procedure was evaluated by an addition-recovery experiment employing urine samples. Recoveries varied from 96.0 to 103% for additions ranging from 0.8 to 3.5 μg L-1 V. The developed procedure allows the determination of vanadium in urine without any sample pretreatment and with minimal dilution of the sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of pre-heating resin composite photo-cured with light-curing units (LCU) by FT-IR. Twenty specimens were made in a metallic mold (4 mm diameter × 2 mm thick) from composite resin-Tetric Ceram® (Ivoclar/Vivadent) at room temperature (25°C) and pre-heated to 37, 54, and 60°C. The specimens were cured with halogen curing light (QTH) and light emitted by diodes (LED) during 40 s. Then, the specimens were pulverized, pressed with KBr and analyzed with FT-IR. The data were submitted to statistical analysis of variance and Kruskal-Wallis test. Study data showed no statistically significant difference to the degree of conversion for the different light curing units (QTH and LED) (p > 0.05). With the increase of temperature there was significant increase in the degree of conversion (p < 0.05). In this study were not found evidence that the light curing unit and temperature influenced the degree of conversion. © 2010 Pleiades Publishing, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Authors - Magno AFF, Martins RP, Vaz LG, Martins LP Objectives - Evaluate the shear bond strength (SBS) and the adhesive remnant index (ARI) of indirect bonded lingual brackets using xenon plasma arc light, light-emitting diode (LED) and conventional quartz-tungsten-halogen light. Material and Methods - Lingual brackets were bonded indirectly to 60 premolars divided to three groups according to the curing light used: Group 1, plasma arc for 6 s; Group 2, LED for 10 s; and Group 3, halogen light for 40 s. After bonding, the specimens were subjected to a shear force until debonding. The debonding pattern was assessed and classified according to the ARI scores. The mean shear bond strengths were accessed by anova followed by the Student-Newman-Keuls test for multiple comparisons. ARI scores were assessed using the chi-square test. Results - The three groups showed significant differences (p < 0.001), with the averages of group 1 < group 2 < group 3. Groups showed no differences regarding ARI scores. Conclusion - Bonding lingual brackets indirectly with plasma arc, during 60% of the time used for the LED, produced lower SBS than obtained with the latter. Using LED during 25% of the time of the halogen light produced lower SBS than obtained with the latter. These differences did not influence the debonding pattern and are clinically acceptable according to the literature. © 2010 John Wiley & Sons A/S.