148 resultados para KOOP HARDNESS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orthodontic mini-implants are used in clinical practice to provide efficient and aesthetically-pleasing anchorage. AIM: To evaluate the hardness Vickers hardness and chemical composition of mini-implant titanium alloys from five commercial brands. METHODS: Thirty self-drilling mini-implants, six each from the following commercial brands, were used: Neodent NEO, Morelli MOR, Sin SIN, Conexão CON, and Rocky Mountain RMO. The hardness and chemical composition of the titanium alloys were performed by the Vickers hardness test and energy dispersive X-ray spectroscopy, respectively. RESULTS: Vickers hardness was significantly higher in SIN implants than in NEO, MOR, and CON implants. Similarly, VH was significantly higher in RMO implants than in MOR and NEO ones. In addition, VH was higher in CON implants than in NEO ones. There were no significant differences in the proportions of titanium and aluminum in the mini-implant alloy of the five commercial brands. Conversely, the proportion of vanadium differed significantly between CON and MOR/NEO implants. CONCLUSIONS: Mini-implants of different brands presented distinct properties of hardness and composition of the alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the cumulative effects of brushing (B) or immersion (I), using different cleansing agents, on the surface roughness, hardness and color stability of a heat-polymerized denture resin, Lucitone 550 (L), and a hard chairside reline resin, Tokuyama Rebase Fast II (T). Methods: A total of 316 specimens (10 x 2 mm) were fabricated. The specimens (n= 9) were divided into brushing or immersion groups according to the following agents: dentifrice/distilled water (D), 1% sodium hypochlorite (Na0C1), Corega Tabs (Pb), 1% chlorhexidine gluconate (Chx), and 0.2% peracetic acid (Ac). Brushing and immersion were tested independently. Assays were performed after 1, 3, 21, 45 and 90 blushing cycles or immersion of 10 seconds each. Data were evaluated statistically by repeated measures ANOVA. Tukey's honestly significant difference (HSD) post-hoc test was used to determine differences between means (a= 0.05). Results: For L there was no statistically significant difference in roughness, except a significant decrease in roughness by brushing with D. T showed a significant effect on the roughness after 90 immersions with Ac. Hardness values decreased for L when specimens were immersed or brushed in Na0C1 and Pb. The hardness of T decreased with increases in the repetitions (immersion or brushing), regardless of the cleaning method. Values of color stability for L resin showed significant color change after brushing with and immersion in Ac and Pb. Brushing with D exhibited a higher incidence of color change. For T there were no significant differences between cleaning agents and repetitions in immersion. A color change was noted after three brushings with the Ac, Chx, and D. Brushing with dentifrice decreased roughness of L. Immersion in or brushing with Na0C1 and Pb decreased the hardness of L. For T, hardness decreased with increases in immersions or brushing. Color changes after the immersion in or brushing with cleaning agents were clinically acceptable according to National Bureau of Standards parameters for both resins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze, through Vickers hardness test and photoelasticity analysis, pre-bent areas, manually bent areas, and areas without bends of 10-mm advancement pre-bent titanium plates (Leibinger system). The work was divided into three groups: group I-region without bend, group II-region of 90° manual bend, and group III-region of 90° pre-fabricated bends. All the materials were evaluated through hardness analysis by the Vickers hardness test, stress analysis by residual images obtained in a polariscope, and photoelastic analysis by reflection during the manual bending. The data obtained from the hardness tests were statistically analyzed using ANOVA and Tukey's tests at a significance level of 5 %. The pre-bent plate (group III) showed hardness means statistically significantly higher (P < 0.05) than those of the other groups (I-region without bends, II-90° manually bent region). Through the study of photoelastic reflection, it was possible to identify that the stress gradually increased, reaching a pink color (1.81 δ / λ), as the bending was performed. A general analysis of the results showed that the bent plate region of pre-bent titanium presented the best results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Indirect dental composites may have adequate clinical performance. However, the literature is scarce regarding indirect composite resins and these solutions should be considered to maintain their properties. The aim of the study was to evaluate the influence of beverages, mouthwashes and bleaching agents on the hardness of indirect composite resins. Methods: Five different brands of indirect composite resins were evaluated: Adoro, Resilab, Cristobal, Sinfony and Epricord. Ten specimens of each brand were immersed in eleven different solutions: four mouthwashes (Listerine, Oral-B, Plax, Periogard), four beverages (coke soft drink, red wine, coffee, orange juice), three dental bleaching agents (16% peroxide of carbamide, 7.5% and 38% peroxide of hydrogen) and artificial saliva (control group). The Knoop hardness was measured before (baseline) and after 12, 24, 36 and 60 hours of immersion in mouthwashes; after 7, 14 and 21 days of immersion in beverages and after 7 and 14 days of immersion in dental bleaching agents. The results were analyzed using 3-way repeated measures ANOVA and Tukey’s test (p<0.05). Results: All resins presented significant decrease on hardness values after immersion process whereas this reduction was higher for Resilab and Sinfony. The latter exhibited the lowest initial values of hardness while Cristobol resin presented the highest hardness values. The mouthwashes promoted a significant decrease in the hardness of specimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical performance of composite resins depends largely on their mechanical properties,and those are influenced by several factors,such as the light-curing mode. The purpose of this study was to evaluate the influence of different light sources on degree of conversion(DC), Knoop hardness(KHN) and plasticization(P) of a composite resin. Disc-shaped specimens (5 x 2 mm) of Esthet-X(Dentsply) methacrylate-based microhybrid composite were light-cured using quartz-tungsten-halogen (QTH) Optilight Plus(Gnatus) or light-emitting diode(LED) Ultraled(Dabi Atlante) curing units at 400 and 340 mW/cm2 of irradiance, respectively. After 24 h, absorption spectra of composite were obtained using Nexus 670(Nicolet)FT-IR spectrometer in order to calculate the DC.The KHN was measured in the HMV-2000(Shimadzu) microhardness tester under 50 g loads for 15 s, and P was evaluated by percentage reductio of hardness after 24 h of alcohol storage. Data were subjected to t-Student test(alpha=0.05).QTH device showed lower P and higher KHN$ than LED (p<0.05), and no difference between the light-curing units was found for DC (p>0.05). The halogen-curing unit with higher irradiance promoted higher KHN and lower softening in alcohol than LED.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Water quality of a fish pond used by UNESP, at Jaboticabal, SP, Brazil, for both fishing and irrigation has been evaluated according to certain limnological parameters and to its phytoplankton composition. During the year, four sampling sites were assigned at the pond: P(1)=inlet water in the pond; P(2)=inlet water from a shrimp pond; P(3)=irrigation spot; and P(4)=outlet water (water flowing directly into another pond). The collected data show a water pond with high concentration of nutrients and chlorophyll-a, and high values of electrical conductivity, total hardness and total dissolved solids, proceeding from the above pond. These factors affected substantially some biological parameters, such as chlorophyll-a and phytoplankton. In P(3), whereas class Zygnematophyceae showed the highest specimens richness, with 34.01%, the Chlorophyceae, that had the highest number of genera, comprehended 33.52% of the total number of individuals. The use of the water fish pond for irrigation must be re-evaluated, due to eutrophic conditions of the water, the presence of potentially toxic cyanobacteria, so as the proper management employed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Com o objetivo de verificar a influência de remanescentes de vegetação ciliar e da ação antrópica na qualidade da água, estudaram-se quatro nascentes, sendo duas com a presença de vegetação natural remanescente e duas com predominância de atividades agrícolas. Essas nascentes fazem parte da bacia hidrográfica do Córrego Rico, estando localizadas nos municípios de Taquaritinga e de Guariba - SP, em duas classes de solo: Argissolo e Latossolo, respectivamente. Definiram-se pontos de coleta da água nas nascentes e ao longo dos cursos d'água (entre 0 a 50 m da nascente), em dois períodos (chuvoso e seco). Foram analisadas as seguintes variáveis: cor, pH, temperatura, turbidez, alcalinidade, dureza total, dureza em magnésio, dureza em cálcio, fósforo, nitrogênio e demanda bioquímica de oxigênio. de maneira geral, ocorreu agrupamento por nascentes e também por períodos, confirmando que os períodos de amostragem, assim como as características e diferentes usos do solo influenciam na qualidade da água das microbacias. As variáveis cor, turbidez, alcalinidade e nitrogênio total foram as que apresentaram maior importância relativa nas variáveis canônicas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O Z. joazeiro é uma espécie florestal de grande importância socioeconômica para a Região Nordeste do Brasil e apresenta dificuldades na germinação das unidades de dispersão, causada pela impermeabilidade à água. Este estudo avaliou tratamentos pré-germinativos de superação de dormência de unidades de dispersão de Z. joazeiro. O experimento foi conduzido em casa de vegetação, no Centro de Ciências Agrárias da Universidade Federal da Paraíba, em Areia, PB, Brasil. Os tratamentos consistiram em: testemunha (unidades de dispersão intactas), escarificação mecânica com lixa d'água, imersão em água, à temperatura ambiente, por 24, 48, 72, 96 e 120 h, imersão em água à temperatura de 70 ºC, por 3 min, e imersão em ácido sulfúrico concentrado por 30, 60, 90, 120 e 150 min. As variáveis avaliadas foram porcentagem de emergência, primeira contagem e velocidade de emergência, comprimento e massa seca de plantas. Os tratamentos que propiciaram máxima emergência de plântulas de Z. joazeiro foram imersão de unidades de dispersão em água fria por 48 h, imersão em água a 70 ºC por 3 min e escarificação manual com lixa, por superar a dureza tegumentar das unidades de dispersão dessa espécie.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)