121 resultados para Implants, Experimental


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This four-experiment series sought to evaluate the potential of children with neurosensory deafness and cochlear implants to exhibit auditory-visual and visual-visual stimulus equivalence relations within a matching-to-sample format. Twelve children who became deaf prior to acquiring language (prelingual) and four who became deaf afterwards (postlingual) were studied. All children learned auditory-visual conditional discriminations and nearly all showed emergent equivalence relations. Naming tests, conducted with a subset of the: children, showed no consistent relationship to the equivalence-test outcomes.. This study makes several contributions: to the literature on stimulus equivalence. First; it demonstrates that both pre- and postlingually deaf children-can: acquire auditory-visual equivalence-relations after cochlear implantation, thus demonstrating symbolic functioning. Second, it directs attention to a population that may be especially interesting for researchers seeking to analyze the relationship. between speaker and listener repertoires. Third, it demonstrates the feasibility of conducting experimental studies of stimulus control processes within the limitations of a hospital, which these children must visit routinely for the maintenance of their cochlear implants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AimTo study osseointegration and bone-level changes at implants installed using either a standard or a reduced diameter bur for implant bed preparation.Material and methodsIn six Labrador dogs, the first and second premolars were extracted bilaterally. Subsequently, mesial roots of the first molars were endodontically treated and distal roots, including the corresponding part of the crown, were extracted. After 3 months of healing, flaps were elevated and recipient sites were prepared in all experimental sites. The control site was prepared using a standard procedure, while the test site was prepared using a drill with a 0.2 mm reduced diameter than the standard one used in the contra-lateral side. After 4 months of healing, the animals were euthanized and biopsies were obtained for histological processing and evaluation.ResultsWith the exception of one implant that was lost, all implants were integrated in mineralized bone. The alveolar crest underwent resorption at control as well as at test sites (buccal aspect similar to 1 mm). The most coronal contact of bone-to-implant was located between 1.2 and 1.6 mm at the test and between 1.3 and 1.7 mm at the control sites. Bone-to-implant contact percentage was between 49% and 67%. No statistically significant differences were found for any of the outcome variables.ConclusionsAfter 4 months of healing, lateral pressure to the implant bed as reflected by higher insertion torques (36 vs. 15 N cm in the premolar and 19 vs. 7 N cm in the molar regions) did not affect the bone-to-implant contact.To cite this article:Pantani F, Botticelli D, Garcia IR Jr., Salata LA, Borges GJ, Lang NP. Influence of lateral pressure to the implant bed on osseointegration: an experimental study in dogs.Clin. Oral Impl. Res. 21, 2010; 1264-1270.doi: 10.1111/j.1600-0501.2009.01941.x.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AimTo evaluate the influence (i) of various implant platform configurations and (ii) of implant surface characteristics on peri-implant tissue dimensions in a dog model.Material and methodsMandibular premolars and first molars were extracted bilaterally in six Labrador dogs. After 3 months of healing, two implants, one with a turned and a second with a moderately rough surface, were installed on each side of the mandible in the premolar region. on the right side of the mandible, implants with a tapered and enlarged platform were used, while standard cylindrical implants were installed in the left side of the mandible. Abutments with the diameter of the cylindrical implants were used resulting in a mismatch of 0.25 mm at the tapered implant sites. The flaps were sutured to allow a non-submerged healing. After 4 months, the animals were sacrificed and ground sections were obtained for histometric assessment.ResultsAll implants were completely osseointegrated. A minimal buccal bone resorption was observed for both implant configurations and surface topographies. Considering the animals as the statistical unit, no significant differences were found at the buccal aspect in relation to bone levels and soft tissue dimensions. The surface topographies did not influence the outcomes either.ConclusionsThe present study failed to show differences in peri-implant tissue dimensions when a mismatch of 0.25 mm from a tapered platform to an abutment was applied. The surface topographies influence a neither marginal bone resorption or peri-implant soft tissue dimension.To cite this article:Baffone GM, Botticelli D, Pantani F, Cardoso LC, Schweikert MT, Lang NP. Influence of various implant platform configurations on peri-implant tissue dimensions: an experimental study in dog.Clin. Oral Impl. Res. 22, 2011; 438-444.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The authors studied the behavior of calcium phosphate materials used as inlay implants into bone cavities prepared in the zygomatic arch of rats. Fifty male albino rats were divided into four groups as follows: group I-preparation of bone cavities which did not receive any implant material as controls; group II-implants of Interpore 200; group III-implants of experimental hydroxylapatite; group IV-implants of experimental hydroxylapatite combined with collagen. The animals were sacrificed after 5, 15, 30, 60 and 120 days and the specimens were submitted to histological analysis. Results showed that the experimental hydroxylapatite used in group III presented better osteogenic properties compared to the other materials. All tested materials were biocompatible, although group IV presented a more intense inflammatory response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: Alterations in implant surfaces can affect periimplant bone formation and shorten the healing time. The goal of the present study was a comparative scanning electron microscopy (SEM)/energy dispersive spectrometry (EDS) and biomechanical evaluation of implants subjected to different surface treatments. Materials and Methods: Four implant surfaces were analyzed in the present study: machined commercial implants (TU); porous-surfaced commercial implants blasted with Al2O3 microspheres and acid-etched (TJA); laser beam-irradiated experimental implants (Laser) and laser beam-irradiated experimental implants with hydroxyapatite coating (HA). One sample for each surface underwent pre-surgery SEM/EDS analysis. Thirty-two implants (8 for each surface treatment) were then inserted into the tibia of 4 rabbits. After 8 weeks, the animals were euthanized and the implants retrieved by reverse torque and processed for post-surgery SEM/EDS analysis. Results: HA implants presented higher removal torque values when compared to Laser, TJA and TU groups. Post-surgery SEM micrographs clearly showed bone formation on all the examined surfaces; however, in the TU group bone covered only some areas of the implant surface, while in TJA, Laser and HA groups the entire implant surfaces were overlaid by newly formed bone. EDS analysis supported the results obtained by SEM and removal torque, showing that concentration of Ca and P increased from TU to TJA, Laser and HA implants. Conclusions: Implants with surfaces modified by laser beam with or without apatite coating showed more promising results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the usefulness of type IIb external skeletal fixators with a transarticular pin in experimental tarsocrural arthrodesis. Twelve adult mongrel dogs of both sexes, ranging in age from two to five years and weighing 12 to 25kg, were used. The configuration of the fixator consisted in the application of a transarticular Steinmann pin and of centrally threaded pins to the proximal portion of the tibia and calcaneus and to the distal portion of the metatarsal bones. In addition, Schanz pins were inserted into the medial and lateral side of the tibia and into the medial side of the metatarsal bones. Radiographs were taken 15; 30 and 45 days after surgery. Bone fusion of the treated joints were observed at 30 days in all animals, and the implants were removed after 45 days. Loosening of the centrally threaded pins was observed in all groups, especially for those applied to the calcaneus. The configuration of the external fixator proposed here was found to be satisfactory in terms of bone union for all joints during the same period, irrespective of the weight of the animal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Bioactive glass and bioactive glass-ceramic cone implants were placed in the rabbit eviscerated socket to assess their biocompatibility. Methods: Fifty-one Norfolk albino rabbits underwent evisceration of the right eye followed by implantation of cones made from Bioglass® 45S5 (control group) and two types of bioactive glass-ceramic (Biosilicate®), a single- and a two-phase bioactive glass-ceramic implants into the scleral cavity. Postoperative reactions, animal behavior and socket conditions were monitored daily. Clinical exam, biochemical evaluations, and orbit computed tomographic scan were done at 7, 90, and 180 days post-procedure. After that, the animals were euthanized, and the orbital content was removed and prepared to light microscopy with morphometric evaluation and scanning electron microscopy examination. Statistical analysis was done by parametric and non-parametric analysis of variance, complemented by Dunn's and Tukey's tests (p<0.05). Results: All animals did not develop systemic toxicity throughout the experimental period and also did not have orbit infection, implant migration or extrusion. Morphological analysis demonstrated pseudocapsule around all implants. Bioglass® and single-phase Biosilicate® implants induced less inflammation and pseudocapsule formation than two-phase Biosilicate® cones. Seven days post-procedure, the inflammatory reaction was intense and gradually decreased throughout the experiment. Tissue reaction was least intense in animals receiving Bioglass® implants. Conclusions: We observe discrete differences among the studied materials, with best responses obtained with use of Bioglass® 45S5 and single-phase Biosilicate®. The authors agree these implants might be useful in the management of the anophthalmic socket. © 2012 Informa Healthcare USA, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate the influence of the width of the buccal bony wall on hard and soft tissue dimensions following implant installation. Material and methods: Mandibular premolars and first molars of six Labrador dogs were extracted bilaterally. After 3 months of healing, two recipient sites, one on each side of the mandible, were prepared in such a way as to obtain a buccal bony ridge width of about 2 mm in the right (control) and 1 mm in the left sides (test), respectively. Implants were installed with the coronal margin flush with the buccal alveolar bony crest. Abutments were placed and the flaps were sutured to allow a non-submerged healing. After 3 months, the animals were euthanized and ground sections obtained. Results: All implants were completely osseointegrated. In respect to the coronal rough margin of the implant, the most coronal bone-to-implant contact was apically located 1.04 ± 0.91 and 0.94 ± 0.87 mm at the test and control sites, respectively, whereas the top of the bony crest was located 0.30 ± 0.40 mm at the test and 0.57 ± 0.49 mm at the control sites. No statistically significant differences were found. A larger horizontal bone resorption, however, evaluated 1 mm apically to the rough margin, was found at the control (1.1 ± 0.7 mm) compared to the test (0.3 ± 0.3 mm) sites, the difference being statistically significant. A thin peri-implant mucosa (2.4-2.6 mm) was found at implant installation while, after 3 months of healing, a biological width of 3.90-4.40 mm was observed with no statistically significant differences between control and test sites. Conclusions: A width of the buccal bony wall of 1or 2 mm at implant sites yielded similar results after 3 months of healing in relation of hard tissue and soft tissues dimensions after implant installation. © 2012 John Wiley & Sons A/S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purposes: The purposes of this study were to evaluate the influence of chronic stress (CS) on implant osseointegration and also to analyze whether alendronate (ALN) therapy could prevent these eventual stress-negative effects. Materials and Methods: Adult male Holtzmann rats were assigned to one of the four experimental groups: AL (ALN; 1mg/kg/week; n=12), ALS (ALN+CS; 1mg/kg/week; n=12), CTL (sterile physiological saline; n=12), or CTLS (sterile physiological saline+CS; n=12). After 58 days of drug therapy, the ALS and CTLS groups were exposed to CS, and 2 days later all animals underwent tibial implant installation. The animals were euthanized 28 days following the operative surgical procedure. Results: It was observed that the CTLS group presented an impairment of bone metabolism represented by lowest levels of bone-specific alkaline phosphatase and bone area fraction occupancy values. Furthermore, these animals presented a higher proportion of empty osteocytic lacunae. In contrast, the ALN therapy showed increased osseointegration and torque value parameters, regardless of stress exposition. Conclusions: Analysis of the data presented suggests that CS partially impairs the osseointegration of tibial implants and that ALN therapy is able to prevent these negative effects. © 2013 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate bone healing around dental implants with established osseointegration in experimental diabetes mellitus (DM) and insulin therapy by histomorphometric and removal torque analysis in a rat model. Materials and methods: A total of 80 male Wistar rats received a titanium implant in the tibiae proximal methaphysis. After a healing period of 60 days, the rats were divided into four groups of 20 animals each: a 2-month control group, sacrificed at time (group A), a diabetic group (group D), an insulin group (group I), and a 4-month control group (group C), subdivided half for removal torque and half for histomorphometric analysis. In the D and I groups the DM was induced by a single injection of 40 mg/kg body weight streptozotocin (STZ). Two days after DM induction, group I received subcutaneous doses of insulin twice a day, during 2 months. Groups C and D received only saline. Two months after induction of DM, the animals of groups D, C and I were sacrificed. The plasmatic levels of glucose (GPL) were monitored throughout the experiment. Evaluation of the percentages of bone-to-implant contact and bone area within the limits of the implant threads was done by histomorphometric and mechanical torque analysis. Data were analyzed by anova at significant level of 5%. Results: The GPL were within normal range for groups A, C and I and higher for group D. The means and standard deviations (SD) for histomorphometric bone area showed significant difference between group D (69.34 ± 5.00%) and groups C (78.20 ± 4.88%) and I (79.63 ± 4.97%). Related to bone-to-implant contact there were no significant difference between the groups D (60.81 + 6.83%), C (63.37 + 5.88%) and I (66.97 + 4.13%). The means and SD for removal torque showed that group D (12.91 ± 2.51 Ncm) was statistically lower than group I (17.10 ± 3.06 Ncm) and C (16.95 ± 5.39 Ncm). Conclusions: Diabetes mellitus impaired the bone healing around dental implants with established osseointegration because the results presented a lower percentage of bone area in group D in relation to groups C and I resulting in a lowest torque values for implant removal. Moreover, insulin therapy prevents the occurrence of bone abnormalities found in diabetic animals and osseointegration was not compromised. © 2012 John Wiley & Sons A/S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To investigate the influence of the presence or absence of keratinized mucosa on the alveolar bony crest level as it relates to different buccal marginal bone thicknesses. Material and methods: In six beagle dogs, the mandibular premolars and first molars were extracted bilaterally. In the right side of the mandible (test), flaps were elevated, and the buccal as well as part of the lingual masticatory mucosa was removed. The flap was released coronally to allow a primary wound closure. In the left side, the wounds were left unsutured with the keratinized mucosa remaining (control). After 3 months of healing, a complete absence of keratinized mucosa was found at the test sites. Two recipient sites were prepared at each side of the mandible, one in the premolar and one in the molar region. A buccal bony ridge width of approximately 1 and 2 mm was obtained at the premolar and molar region, respectively. Implants were installed with the shoulder flush with the buccal alveolar bony crest, and abutments were connected to allow a nonsubmerged healing. At least 2 mm of keratinized mucosa was surrounding the control sites, while at the test sites, the implants were bordered by alveolar mucosa. After 3 months, the animals were euthanized and ground sections obtained. Results: A higher vertical bony crest resorption was observed at the test compared with the control sites both at the premolar and molar regions, the differences being statistically significant. The top of the peri-implant mucosa was located more coronally at the control compared with the test sites. The horizontal resorption measured 1 mm below the implant shoulder was similar at the test and control sites. Only limited differences were found between premolar and molar sites, with the exclusion of the horizontal resorption that was higher at the test compared with the control sites. Conclusions: A higher alveolar buccal bony crest resorption and a more apical soft tissue marginal position should be expected, when implants are surrounded with thin alveolar mucosa at the time of installation, independently of the thickness of the buccal bony crest. © 2013 John Wiley & Sons A/S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the influence of the configuration of the marginal aspect of implants placed immediately into extraction sockets on peri-implant hard tissue adaptation. Material and methods: In 6 Labrador dogs, endodontic treatments of the mesial roots of 1M1 were performed and the distal roots were removed. 2P2 was extracted as well. Implants were immediately placed in the center of the distal alveoli. Cylindrical straight implants were installed in the right side of the mandible (Control), while, in the left side, implants with a reduced diameter in the coronal portion, yielding an indentation in the surface continuity (Test), were installed. Cover screws were affixed, and the flaps were sutured to allow non-submerged healing. After 4 months of healing, histological slides were obtained for assessments. Results: A buccal resorption of 1.58 ± 1.28 and 1.90 ± 1.93 mm at the control and of 0.26 ± 0.90 and 0.14 ± 0.66 mm at the test sites was observed at the premolar and molar regions, respectively. The buccal coronal level of osseointegration was located apically to the margin of the smooth/rough surface border by 2.40 ± 0.90 and 3.70 ± 0.87 mm at the control sites and 1.19 ± 0.45 and 2.16 ± 0.96 mm at the test sites at the premolar and molar sites, respectively. All differences yielded statistical significance. Conclusions: The use of implants with a reduced diameter in their coronal aspect may contribute to preservation of the buccal bony crest in a more coronal level compared with conventional implants. Thus, the study confirmed the efficacy of the platform switching concept. © 2013 John Wiley & Sons A/S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)