122 resultados para Image processing computer-assisted


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper considers a study of the anatomical features of the cardiac system and a three-dimensional model of the different tunics that comprise the heart wall, for processing and quality control of radiological images. The structures are built by the layer overlapping method, where a layer can be understood as a slice of the three-dimensional object. The pericardium, myocardium and endocardium were represented with three-dimensional cylinders and hexagons. The spatial arrangement of the cardiac system is determined by an background image of a real model, which values are defined according to the shape of the region and on the anatomical patients characteristics. The results are significant, considering the anatomical structures details, as well as the representation of the thicknesses of the regions of the heart wall. The validation of the anatomical model was accomplished through comparisons with dimensions obtained from a real model and allows verifying that the model is appropriate. The degree of representation will allow the verification of the influence of radiological parameters, morphometric peculiarities and stage of the diseases on the quality of the images, as well as on the performance of the Computer-Aided Diagnosis (CAD).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Image segmentation is a process frequently used in several different areas including Cartography. Feature extraction is a very troublesome task, and successful results require more complex techniques and good quality data. The aims of this paper is to study Digital Image Processing techniques, with emphasis in Mathematical Morphology, to use Remote Sensing imagery, making image segmentation, using morphological operators, mainly the multi-scale morphological gradient operator. In the segmentation process, pre-processing operators of Mathematical Morphology were used, and the multi-scales gradient was implemented to create one of the images used as marker image. Orbital image of the Landsat satellite, sensor TM was used. The MATLAB software was used in the implementation of the routines. With the accomplishment of tests, the performance of the implemented operators was verified and carried through the analysis of the results. The extration of linear feature, using mathematical morphology techniques, can contribute in cartographic applications, as cartographic products updating. The comparison to the best result obtained was performed by means of the morphology with conventional techniques of features extraction. © Springer-Verlag 2004.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Muita atenção tem sido dada ao desenvolvimento de inseticidas vegetais buscando-se um efetivo controle de ectoparasitas de bovinos, sem prejudicar animais, consumidores e meio ambiente. Este estudo, realizado de abril a julho de 2008, na Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) Pecuária Sudeste, em São Carlos, SP, Brasil, avaliou a eficácia de uma torta comercial de nim (Azadirachta indica) no controle da mosca-dos-chifres (Haematobia irritans) em bovinos. A torta de nim, misturada ao sal mineral na concentração de 2%, foi fornecida a 20 vacas Nelore, durante nove semanas, e sua eficácia foi monitorada através de contagens semanais nos grupos tratado e controle. Infestações individuais foram registradas por meio de fotos digitais em todos os animais de ambos os grupos, e o número de moscas foi, posteriormente, quantificado com o auxílio de um sistema de análise de imagem computadorizado. A quantificação dos componentes da torta de nim, por cromatografia líquida, revelou a presença de azadiractina (421 mg.kg-1) e 3-tigloyl-azadirachtol (151 mg.kg-1). A adição da torta de nim a 2% reduziu o consumo de sal mineral em cerca de 22%. O tratamento com torta de nim a 2% não reduziu as infestações por mosca-dos-chifres em bovinos durante as nove semanas do estudo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to conduct a critical literature review about the technique of computer-guided surgery in implantology to highlight the indications, purposes, immediate loading of implants and complications, protocol of fabrication, and functioning of virtual planning software. This literature review was based on OLDMEDLINE and MEDLINE databases from 2002 to 2010 using the key words "computer-guided surgery" and "implant-supported prosthesis." Thirty-four studies regarding this topic were found. According to the literature review, it was concluded that the computer-assisted surgery is an excellent treatment alternative for patients with appropriate bone quantity for implant insertion in complete and partially edentulous arches. The Procera Nobel Guide software (Nobel Biocare) was the most common software used by the authors. In addition, the flapless surgery is advantageous for positioning of implants but with accurate indication. Although the computer-guided surgery may be helpful for virtual planning of cases with severe bone resorption, the conventional surgical technique is more appropriate. The surgical guide is important for insertion of the implants regardless of the surgical technique, and the success of immediate loading after computer-guided surgery depends on the accuracy of clinical and/or laboratorial steps.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: a reabsorção radicular apical é uma condição comumente observada durante e após o tratamento ortodôntico e fatores como tipo de aparelhagem ortodôntica utilizada, magnitude das forças aplicadas e duração do tratamento podem estar relacionados ao processo de arredondamento do ápice radicular. Buscou-se avaliar, por meio de imagens radiográficas computadorizadas, a quantidade de reabsorção no ápice radicular, quando da utilização de duas diferentes técnicas de mecânica ortodôntica fixa: Edgewise com acessórios padrão e Edgewise com acessórios totalmente programados. METODOLOGIA: a amostra constituiu-se de 20 pacientes tratados pelo mesmo profissional na Clínica de Ortodontia da Faculdade de Odontologia de Araçatuba - UNESP. Os pacientes foram divididos em dois grupos: grupo 1 (Tratados com Edgewise com acessórios padrão e fios de aço) e grupo 2 (Tratados com Edgewise com acessórios totalmente programados e fios de níquel-titânio). A avaliação radiográfica digital foi realizada por um único operador por meio de exposições radiográficas digitais feitas no início do tratamento ortodôntico, após retração de caninos e final de tratamento, utilizando o sistema de escores proposto por Levander e Malmgren (1988). RESULTADOS E CONCLUSÕES: a análise dos escores permitiu concluir que o tratamento ortodôntico empregando a técnica Edgewise com acessórios totalmente programados e fios de níquel-titânio apresentou menores graus de reabsorção radicular apical, em comparação à técnica Edgewise com acessórios padrão e fios de aço. Observou-se que, independentemente da técnica empregada, o tratamento ortodôntico como um todo apresentou um grau moderado de reabsorção radicular apical.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of this work is to assess the efficacy of texture measures for estimating levels of crowd densities ill images. This estimation is crucial for the problem of crowd monitoring. and control. The assessment is carried out oil a set of nearly 300 real images captured from Liverpool Street Train Station. London, UK using texture measures extracted from the images through the following four different methods: gray level dependence matrices, straight lille segments. Fourier analysis. and fractal dimensions. The estimations of dowel densities are given in terms of the classification of the input images ill five classes of densities (very low, low. moderate. high and very high). Three types of classifiers are used: neural (implemented according to the Kohonen model). Bayesian. and an approach based on fitting functions. The results obtained by these three classifiers. using the four texture measures. allowed the conclusion that, for the problem of crowd density estimation. texture analysis is very effective.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A body of research has developed within the context of nonlinear signal and image processing that deals with the automatic, statistical design of digital window-based filters. Based on pairs of ideal and observed signals, a filter is designed in an effort to minimize the error between the ideal and filtered signals. The goodness of an optimal filter depends on the relation between the ideal and observed signals, but the goodness of a designed filter also depends on the amount of sample data from which it is designed. In order to lessen the design cost, a filter is often chosen from a given class of filters, thereby constraining the optimization and increasing the error of the optimal filter. To a great extent, the problem of filter design concerns striking the correct balance between the degree of constraint and the design cost. From a different perspective and in a different context, the problem of constraint versus sample size has been a major focus of study within the theory of pattern recognition. This paper discusses the design problem for nonlinear signal processing, shows how the issue naturally transitions into pattern recognition, and then provides a review of salient related pattern-recognition theory. In particular, it discusses classification rules, constrained classification, the Vapnik-Chervonenkis theory, and implications of that theory for morphological classifiers and neural networks. The paper closes by discussing some design approaches developed for nonlinear signal processing, and how the nature of these naturally lead to a decomposition of the error of a designed filter into a sum of the following components: the Bayes error of the unconstrained optimal filter, the cost of constraint, the cost of reducing complexity by compressing the original signal distribution, the design cost, and the contribution of prior knowledge to a decrease in the error. The main purpose of the paper is to present fundamental principles of pattern recognition theory within the framework of active research in nonlinear signal processing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Image orientation is a basic problem in Digital Photogrammetry. While interior and relative orientations were succesfully automated, the same can not be said about absolute orientation. This process can be automated by using an approach based on relational matching and a heuristic that uses the analytical relation between straight features in the object space and its homologous in the image space. A build-in self-diagnosis is also used in this method, that is based on the implementation of data snooping statistic test in the process of spatial resection, using the Iterated Extended Kalman Filtering (IEKF). The aim of this paper is to present the basic principles of the proposed approach and results based on real data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Metallographic techniques and digital image processing have been used to investigate heat-treated Ti-6Al-4V pitting corrosion, often used as aircraft components. LM and SEM metallography of 'as received', annealed (heating up to 800 degreesC/30 min and cooling furnace) and aged (heating up to 900 degreesC/30 min, quenching in water, heating up to 540 degreesC/240 min and again water-quenched) microstructures reveal pitting sites at primary and secondary alpha/beta interfaces. Microstructural arrangements influence and corrosive environment association on pit morphology could be demonstrated by digital image analysis and results statistical treatment. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Geometric accuracy of a close-range photogrammetric system is assessed in this paper considering surface reconstruction with structured light as its main purpose. The system is based on an off-the-shelf digital camera and a pattern projector. The mathematical model for reconstruction is based on the parametric equation of the projected straight line combined with collinearity equations. A sequential approach for system calibration was developed and is presented. Results obtained from real data are also presented and discussed. Experiments with real data using a prototype have indicated 0.5mm of accuracy in height determination and 0.2mm in the XY plane considering an application where the object was 1630mm distant from the camera.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We outline a method for registration of images of cross sections using the concepts of The Generalized Hough Transform (GHT). The approach may be useful in situations where automation should be a concern. To overcome known problems of noise of traditional GHT we have implemented a slight modified version of the basic algorithm. The modification consists of eliminating points of no interest in the process before the application of the accumulation step of the algorithm. This procedure minimizes the amount of accumulation points while reducing the probability of appearing of spurious peaks. Also, we apply image warping techniques to interpolate images among cross sections. This is needed where the distance of samples between sections is too large. Then it is suggested that the step of registration with GHT can help the interpolation automation by simplifying the correspondence between points of images. Some results are shown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess positive end-expiratory pressure (PEEP)-induced lung overdistension and alveolar recruitment in six patients with acute lung injury (ALI) using a computed tomographic (CT) scan method. Lung overdistension was first determined in six healthy volunteers in whom CT sections were obtained at FRC and at TLC with a positive airway pressure of 30 cm H2O. In patients, lung volumes were quantified by the analysis of the frequency distribution of CT numbers on the entire lung at zero end-expiratory pressure (ZEEP) and PEEP. In healthy volunteers at FRC, the distribution of the density histograms was monophasic with a peak at -791 ± 12 Hounsfield units (HU). The lowest CT number observed was -912 HU. At TLC, lung volume increased by 79 ± 35% and the peak CT number decreased to -886 ± 26 HU. More than 70% of the increase in lung volume was located below -900 HU, suggesting that this value can be considered as the threshold separating normal aeration from overdistension. In patients with ALI, at ZEEP the distribution of density histograms was either monophasic (n = 3) or biphasic (n = 3). The mean CT number was -319 ± 34 HU. At PEEP 13 ± 3 cm H2O, lung volume increased by 47 ± 19% whereas mean CT number decreased to -538 ± 171 HU. PEEP induced a mean alveolar recruitment of 320 ± 160 ml and a mean lung overdistension of 238 ± 320 ml. In conclusion, overdistended lung parenchyma of healthy volunteers is characterized by a CT number below -900 HU. This threshold can be used in patients with ALI for differentiating PEEP-induced alveolar recruitment from lung overdistension.