90 resultados para Experimental Low Back Pain
Resumo:
High (H) and low (L) responder mice were selected for their ability to produce antibodies against sheep and human erythrocytes (Selection IV-A). In this selection, the difference in antibody responsiveness between H and L lines (HIV-A and LIV-A mice, respectively) was shown to depend mainly on macrophage function. The more rapid catabolism of antigens by macrophages in L mice has been suggested as the main cause of the low antibody production. Due to this high macrophage activity, L animals have been described as more resistant than H animals to intracellular pathogens. These animals were utilized as an experimental model of paracoccidioidomycosis. HIV-A and LIV-A mice were infected with Paracoccidioides brasiliensis by the intravenous route. As expected, H mice were more susceptible to P. brasiliensis with a shorter survival time and higher levels of specific antibodies when compared to L mice. Contrasting with the survival time, the lungs, spleen and liver from H mice showed typical nodular granulomas containing epithelioid and giant cells and few fungi. on the other hand, in LN-A mice, the lesions of these organs were characterized by looser granulomas with irregular borders and the presence of a large number of fungi, However, the adrenal gland showed different lesion patterns. In H mice these lesions were extensive and characterized by loose granulomas with numerous fungi, while in LIV-A mice the lesions were small and limited to the cortex. Moreover the HIV-A mice presented higher levels of serum corticosterone when compared to LIV-A ones. The higher susceptibility of H mice could be attributed to the extensive lesions of the adrenal glands. These results suggest the use of the H line from the IV-A Selection as an experimental model for further studies of adrenal involvement in paracoccidioidomycosis.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A leishmaniose é uma infecção parasitária cuja imunidade protetora envolve a ativação de macrófagos. Neste trabalho avaliamos a susceptibilidade de camundongos H e L (bons e maus produtores de anticorpos, respectivamente) da seleção IV-A, à infecção com o protozoário L. donovani. Camundongos H infectados com 10(7) amastigotas por via intravenosa foram mais suscetíveis, apresentando maior carga parasitária tanto no fígado quanto no baço. Após 60 dias de infecção ambas as linhagens apresentaram um aumento no índice esplênico. Esta esplenomegalia foi conseqüência, pelo menos parcialmente, de um aumento no número de células esplênicas. Os resultados indicam que a seleção IV-A é susceptível à infecção com L. donovani e que dentro desta seleção a linhagem H apresenta maior suscetibilidade do que a linhagem L.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Heat recovery devices are important in the optimization of thermal systems, since they can be used to reduce thermal losses to the environment. The use of heat pipes in these types of equipment can provide heat recoveries of higher efficiency, since both fluid flows are external and there are less contamination risks between the hot and cold fluids. The objective of this work is to study a heat recovery unit constructed with heat pipes and mainly, to analyze the influence of the inclination of the heat pipes on the performance of the equipment. For this analysis, a heat recovery unit was constructed which possesses 48 finned heat pipes in triangular geometry, the evaporator and condenser being of the same length. This unit was tested in an air-air system simulating a heat recovery process in which heat was supplied to the hot fluid by electrical resistances. The results have shown that there exists an inclination at which the system has a better performance, but for higher inclinations there is no significant increase of the efficiency of the system. This paper also presents the influence of inclination of heat pipes on effectiveness and NTU parameters which are important in heat exchanger design.
Resumo:
This study aimed to evaluate the effectiveness of low intensity laser therapy (LILT) in 30 patients presenting temporomandibular joint (TMJ) pain and mandibular dysfunction in a random and double-blind research design. The sample, divided into experimental group (1) and placebo group (2), was submitted to the treatment with infrared laser (780 nm, 30 mW, 10 s, 6.3 J/cm2) at three TMJ points. The treatment was evaluated throughout six sessions and 15, 30 and 60 days after the end of the therapy, through visual analogue scale (VAS), range of mandibular movements and TMJ pressure pain threshold. The results showed a reduction in VAS (p < 0.001) and through the ANOVA with repeated measures it was observed that the groups did not present statistically significant differences (P = 0.2060), as the averages of the evaluation times (P = 0.3955) and the interaction groups evaluation times (P = 0.3024), considering the MVO. The same occurred for RLE (P = 0.2988, P = 0.1762 and P = 0.7970), LLE (P = 0.3265, P = 0.4143 and P = 0.0696), PPTD (P = 0.1558, P = 0.4695 and P = 0.0737) and PPTE (P = 0.2376, P = 0.3203 and P = 0.0624). For PE, there were not statistically significant differences for groups (P = 0.7017) and the interaction groups evaluation times (P = 0.6678), even so in both groups the PE varied with time (P = 0.0069). © 2005 Blackwell Publishing Ltd.
Resumo:
Toothpastes usually contain detergents, humectants, water colorant, fluoride and thickeners (e.g. silica). Tooth wear has a multi-factorial etilology and the use of abrasive dentifrices is related to abrasion of dental tissues during toothbrushing. This study evaluated in vitro the abrasiveness of a commercial silica gel low-abrasive dentrifice compared to an experimental dentifrice containing vegetable (almond) oil. Distilled water served as a control group. Acrylic specimens (8 per group) were submitted to simulated toothbrushing with slurries of the commercial dentifrice experimental dentifrice, almond oil and water in an automatic brushing machine programmed to 30,000 brush strokes for each specimen which is equivalent to 2 years of manual toothbrushing. Thereafter, surface roughness (Ra) of the specimens was analyzed with a Surfcorder SE 1700 profilometer. Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) in the surface roughness after brushing with water almond oil experimental dentifrice. The commercial dentifrice produced rougher surfaces compared to the control and abrasive free products (p<0.05). Further studies are necessary in confirm the potential benefits of using vegetable oil in toothpaste as an alternative in abrasives in an attempt to minimize the tooth wear caused by toothbrushing.
Resumo:
This study investigated the effect of low-level laser therapy (LLLT) on the masticatory performance (MP), pressure pain threshold (PPT), and pain intensity in patients with myofascial pain. Twenty-one subjects, with myofascial pain according to Research Diagnostic Criteria/temporomandibular dysfunction, were divided into laser group (n = 12) and placebo group (n = 9) to receive laser therapy (active or placebo) two times per week for 4 weeks. The measured variables were: (1) MP by analysis of the geometric mean diameter (GMD) of the chewed particles using Optocal test material, (2) PPT by a pressure algometer, and (3) pain intensity by the visual analog scale (VAS). Measurements of MP and PPT were obtained at three time points: baseline, at the end of treatment with low-level laser and 30 days after (follow-up). VAS was measured at the same times as above and weekly throughout the laser therapy. The Friedman test was used at a significance level of 5 % for data analysis. The study was approved by the Ethics Committee of the Federal University of Sergipe (CAAE: 0025.0.107.000-10). A reduction in the GMD of crushed particles (p < 0.01) and an increase in PPT (p < 0.05) were seen only in the laser group when comparing the baseline and end-of-treatment values. Both groups showed a decrease in pain intensity at the end of treatment. LLLT promoted an improvement in MP and PPT of the masticatory muscles. © 2012 Springer-Verlag London.
Resumo:
Objective: This study aims to investigate the effects of low-level laser therapy (LLLT) on biceps brachi muscular fatigue in 20 young females. Background data: Exhausting physical activity leads to muscular fatigue, which could decrease muscular strength, and may cause impairment in motor control and muscle pain. Several biochemical and biophysical resources have been studied in an attempt to accelerate the recovery of muscle fatigue. Among these, LLLT is emphasized. Methods: Twenty subjects were randomized in one laser group and one placebo group in two sessions of a crossover design experimental procedure; the second session taking place within 7 days of the first. In the first session, subjects underwent a collection of surface electromyographic (SEMG) data of the biceps brachii muscle, followed by active or placebo LLLT at the same muscle, followed then by another EMG sample of biceps brachii. Blood samples were collected five times during the experimental procedure. Second session procedures were identical to the first, with exception of LLLT, which was the opposite of the first session. The fatigue protocol consisted of 60sec of elbow flexion-extension movement performed with 75% of one maximum repetition. Blood lactate, EMG fatigue, and the number of elbow flexion-extension repetitions during the fatigue protocol were used to evaluate the effects of laser therapy (808nm wavelength, 100mW output power, power density of 35.7 W/cm(2), 70sec each point and 7J/point on eight points). Results: No statistical differences were found for eletromyographic fatigue and blood lactate values between groups. Mean numbers of elbow flexion-extension repetitions were 22.6 +/- 7.58 after placebo, and 25.1 +/- 9.89 after active LLLT group, but these differences were not statistically significant (p=0.342). Conclusions: LLLT had limited effects on delaying muscle fatigue in a young female sample, although a tendency was observed in the active laser group toward showing lower electromyography fatigue of biceps brachii muscle. No intergroup differences were found in the number of muscle contractions and lactate concentration.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The problem of shock generated vibration is very common in practice and difficult to isolate due to the high levels of excitation involved and its transient nature. If not properly isolated it could lead to large transmitted forces and displacements. Typically, classical shock isolation relies on the use of passive stiffness elements to absorb energy by deformation and some damping mechanism to dissipate residual vibration. The approach of using nonlinear stiffness elements is explored in this paper, focusing in providing an isolation system with low dynamic stiffness. The possibilities of using such a configuration for a shock mount are studied experimentally following previous theoretical models. The model studied considers electromagnets and permanent magnets in order to obtain nonlinear stiffness forces using different voltage configurations. It is found that the stiffness nonlinearities could be advantageous in improving shock isolation in terms of absolute displacement and acceleration response when compared with linear elastic elements. Copyright (C) 2015 Elsevier Ltd. All rights reserved
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)