142 resultados para Crowns (Dentistry)
Resumo:
Glass ionomer cements (GICs) are largely employed in Dentistry for several applications, such as luting cements for the attachment of crowns, bridges, and orthodontic brackets as well as restorative materials. The development of new glass systems is very important in Dentistry to improve of the mechanical properties and chemical stability. The aim of this study is the preparation of two glass systems containing niobium in their compositions for use as GICs. Glass systems based on the composition SiO2,Al2O3-Nb2O5-CaO were prepared by chemical route at 700degreesC. The XRD and DTA results confirmed that the prepared materials are glasses. The structures of the obtained glasses were compared to commercial material using FTIR, Al-27 and Si-29 MAS-NMR. The analysis of FTIR and MAS-NMR spectra indicated that the systems developed and commercial material are formed by SiO4 and AlO4 linked tetrahedra. These structures are essential to get the set time control and to have cements. These results encourage further applications of the experimental glasses in the formation of GICs. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Dental ceramics are presented within a simplifying framework allowing for facile understanding of their development, composition and indications. Engineering assessments of clinical function are dealt with and literature is reviewed on the clinical behaviour of all-ceramic systems. Practical aspects are presented regarding the choice and use of dental ceramics to maximize aesthetics and durability, emphasizing what we know and how we know it.
Resumo:
AimTo evaluate prospectively the clinical and radiographic outcomes after 2 years of loading of 6 mm long moderately rough implants supporting single crowns in the posterior regions.Material and methodsForty SLActive Straumann (R) short (6 mm) implants were placed in 35 consecutively treated patients. Nineteen implants, 4.1 mm in diameter, and 21 implants, 4.8 mm in diameter, were installed. Implants were loaded after 6 weeks of healing. Implant survival rate, marginal bone loss and resonance frequency analysis (RFA) were evaluated at different intervals. The clinical crown/implant ratio was also calculated.ResultsTwo out of 40 implants were lost before loading. Hence, the survival rate before loading was 95%. No further technical or biological complications were encountered during the 2-year follow-up. The mean marginal bone loss before loading was 0.34 +/- 0.38 mm. After loading, the mean marginal bone loss was 0.23 +/- 0.33 and 0.21 +/- 0.39 mm at the 1- and 2-year follow-ups. The RFA values increased between insertion (70.2 +/- 9) and the 6-week evaluation (74.8 +/- 6.1). The clinical crown/implant ratio increased with time from 1.5 at the delivery of the prosthesis to 1.8 after 2 years of loading.ConclusionShort implants (6 mm) with a moderately rough surface loaded early (after 6 weeks) during healing yielded high implant survival rates and moderate loss of bone after 2 years of loading. Longer observation periods are needed to draw more definite conclusions on the reliability of short implants supporting single crowns.To cite this article:Rossi F, Ricci E, Marchetti C, Lang NP, Botticelli D. Early loading of single crowns supported by 6-mm-long implants with a moderately rough surface: a prospective 2-year follow-up cohort study.Clin. Oral Impl. Res. 21, 2010; 937-943.doi: 10.1111/j.1600-0501.2010.01942.x.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
STATEMENT OF PROBLEM: Despite careful procedures, master stone dies may be damaged during laboratory procedures. The dentist routinely adjusts castings because the marginal fit of casting is not as accurate as on the dies. PURPOSE: This study evaluated the technique of internal adjustment of castings with use of duplicated stone dies and a disclosing agent to improve marginal fit discrepancy. MATERIAL AND METHODS: Thirty-two nickel-chromium copings were fabricated and simulated standard clinical and laboratory procedures with 2 variables: tooth preparation convergence angles of 6 and 18 degrees, with or without internal relief. Master stone dies and their duplicates were selected for coping construction and internal adjustment, respectively. A specimen positioning device was coupled with a Toolmakers microscope to allow reproducibility of measurements. Each coping was evaluated at 8 locations of its marginal perimeter, before and after internal adjustment. RESULTS: Marginal fit discrepancy of copings were significantly reduced with an internal adjustment technique (mean > 52%) for all experimental groups. Tooth preparations with greater convergence and internally relieved castings recorded a better marginal fit. CONCLUSION: The casting internal adjustment technique with use of duplicated stone dies and a disclosing agent substantially reduced marginal fit discrepancy.
Resumo:
Although visualization in the field of dentistry has some of the same requirements as the medicine field, the differences in goal demand specific approaches. This paper reports on the implementation of two fundamentally different approaches to reconstruction of structures from planar cross sections and their application to dentistry data. One of the approaches was an implementation of a distance-based sampling technique, and the other is a new algorithm, based on the Delaunay triangulation. Both were tested using contour data of teeth and the results are compared here in the light of the target applications, which are teaching and training dentistry, as well as simulation of dental procedures and illnesses. Widely mentioned problems encountered in local reconstruction methods such as marching cubes for these cases are clearly illustrated in this paper, and a very satisfactory alternative is given. © 2000 SPIE and IS&T.
Resumo:
Intrauterine Dentistry is a highly relevant subject of our time. The use of preventive measures in the intrauterine stage can avoid several diseases, among these, dental caries. The WHO advises that from the 4th month of pregnancy, women should avoid the intake of sugar, so that the fetus, future child, does not develop an exaggerated attraction for these types of foods, thus being susceptible to caries. Through questionnaires sent to gynecologist-obstetricians and dentists, this research investigated the information they have about this subject and how they instruct their patients. Questionnaires were also sent to pregnant women requesting information about the instructions they had received for the prevention of oral diseases of their fetus. Seventy-one percent of the dentists and 80% of the gynecologist-obstetricians reported having instructed the pregnant women to reduce the intake of sugar. However, only 13.6% of the dentists and no gynecologist-obstetrician instructed the reduction of sugar intake between the 12th and 18th week of pregnancy. A total of 42.2% of the pregnant women referred to these instructions, but none received instruction as to the specific period of the 12th and 18th week. An ideal model of treatment for pregnant women must include integrated and multiprofessional treatment, in which general dentists and gynecologist-obstetricians work together with the participation of the patient.
Resumo:
This study investigated what are the main reasons that led parents to enroll children in a clinic for infants. This was studied by consulting 1368 records during the period from July 1996 to August 2001. The predominant reason for enrolling was orientation/prevention followed by other and treatment. This study demonstrated that a program for children from the first year of life encourages parents to have a new vision of dentistry.
Resumo:
Caries of primary incisors is a common problem in paediatric dentistry in some countries. The restoration of primary incisors which have been severely damaged by early childhood caries or trauma is also a difficult challenge for clinicians. This case report describes an indirect technique for the restoration of primary anterior teeth using composite resin reinforced with a fibreglass post. Over a one-year period, the crowns have demonstrated good retention and aesthetic results. The restorations were provided in two short chair-side sections, with satisfactory patient cooperation. © 2005 BSPD and IAPD.
Resumo:
Odontomas are developmental disturbances which manifest in the form of denticles or amorphous informes masses comprising all dental tissues, especially enamel and dentin, with variable amounts of pulp and cement. We describe here two clinical cases of odontomas in children, focusing on diagnostic means and the importance of early treatment of these lesions. The standard treatment for the two present cases was surgical removal.
Resumo:
Dentigerous cysts are benign odontogenic cysts associated with the crowns of permanent teeth. They are usually single in occurrence and located in the mandible. The purpose of this case report was to describe the management of 2 dentigerous cysts in children. The treatments instituted were the extraction of the deciduous tooth involved followed by marsupialization in the first case and enucleation in the second one. Both treatments allowed rapid healing of the lesion and eruption of the permanent teeth without the need for orthodontic treatment.
Resumo:
The aim of this study was to determine whether there are differences in the attitudes of Dentistry School Professors from two universities, one private and one public concerning HIV-positive patients or HIV-positive health care professionals. A questionnaire Was handled to all profession at the Araçatuba Dental School of São Paulo State University - FOA-UNESP (public) and Lins Dental School of the Piracicaba Methodist University - FOL-UNIMEP (private). When asked if they would be willing to be treated by an HIV-infected health care professional, 38.9% of the 77 professors at FOA-UNESP replied that they would accept only non-invasive treatments and 13% would not accept any kind of treatment; the same applied to 42.4% and 15.2% of the 33 FOL-UNIMEP professors. Among the 54 professors at FOA-UNESP and 27 at FOL-UNIMEP providing clinical service, only 31.5% and 18.5% stated that they treat HIV-infected persons like any other patient. The results were very similar in both schools. Although they reported that they taught their students not to act in a discriminatory manner towards HIV-positive patient the professors themselves showed prejudice towards infected patients and professionals. Consequently, this topic trust be further debated in the academic milieu.
Resumo:
As the adaptation of titanium crowns obtained by Rematitan Plus investment, specific for titanium, is not recognized to be suitable, this study evaluated the effect of the concentration of the specific liquid and the temperature of the mold of investments on the internal misfit of crowns cast on commercially pure titanium. Individual dies of epoxy resin were obtained, representing teeth prepared for full-crown restoration with a 6-degree axial surface convergence angle and shoulder (1.0 mm). For the waxing of each crown, a ring-shaped stainless steel matrix (8.0mm internal diameter; 7.5 mm height) was adapted above the individual dies of epoxy resin. The Rematian Plus investment was mixed according to the manufacturer's instructions using two different concentrations of the specific liquid: 100%, 75%. Casting was performed in a Discovery Plasma Ar-arc vacuum-pressure casting machine with molds at temperatures of 430°C, 515°C and 600°C. The crowns were cleaned individually in a solution (1% HF + 13% HNO3) for 10 min using a ultrasonic cleaner, with no internal adaptations, and luted with zinc phosphate cement under a 5 kg static load. The crown and die assemblies were embedded in resin and sectioned longitudinally. The area occupied by cement was observed using stereoscopic lens (10X) and measured by the Leica Qwin image analysis system (mm2). The data for each experimental condition (n=8) were analyzed by Kruskal-Wallis non-parametric test (á=0.05). The results showed that liquid dilution and the increase in mold temperature did not significantly influence the levels of internal fit of the cast titanium crowns. The lowest means (±SD) of internal misfit were obtained for the 430°C/100%: (7.25 mm2 ±1.59) and 600°C/100% (8.8 mm2 ±2.25) groups, which presented statistically similar levels of internal misfit.
Resumo:
Aim: The purpose of this review is to present the potential for the incorporation of ozone therapy into the practice of dentistry. Background: Ozone gas has a high oxidation potential and is 1.5 times greater than chloride when used as an antimicrobial agent against bacteria, viruses, fungi, and protozoa. It also has the capacity to stimulate blood circulation and the immune response. Such features justify the current interest in its application in medicine and dentistry and have been indicated for the treatment of 260 different pathologies. It can be used for the treatment of alveolitis as a replacement for antibiotic therapy, as a mouthwash for reducing the oral microflora, as well as the adherence of microorganisms to tooth surfaces. Ozone has been shown to stimulate remineralization of recent caries-affected teeth after a period of about six to eight weeks. Conclusion: The future of ozone therapy must focus on the establishment of safe and well-defined parameters in accordance with randomized, controlled trials to determine the precise indications and guidelines in order to treat various medical and dental pathologies. Scientific support, as suggested by demonstrated studies, for ozone therapy presents a potential for an atraumatic, biologically-based treatment for conditions encountered in dental practice.
Resumo:
Several studies have reported the benefits of sonic and/or ultrasonic instrumentation for root debridement, with most of them focusing on changes in periodontal clinical parameters. The present study investigated possible alterations in the tensile bond strength of crowns cemented with zinc phosphate cement to natural teeth after ultrasonic instrumentation. Forty recently extracted intact human third molars were selected, cleaned and stored in physiologic serum at 4°C. They received standard preparations, at a 16° convergence angle, and AgPd alloy crowns. The crowns were cemented with zinc phosphate cement and then divided into four groups of 10 teeth each. Each group was then subdivided into two subgroups, with one of the subgroups being submitted to 5,000 thermal cycles ranging from 55 ± 2 to 5 ± 2°C, while the other was not. Each group was submitted to ultrasonic instrumentation for different periods of time: group 1 - 0 min (control), group 2 - 5 min, group 3 - 10 min, and group 4 - 15 min. Tensile bond strength tests were performed with an Instron testing machine (model 4310). Statistical analysis was performed using ANOVA and Tukey's test at the 5% level of significance. A significant reduction in the tensile bond strength of crowns cemented with zinc phosphate and submitted to thermal cycles was observed at 15 min (196.75 N versus 0 min = 452.01 N, 5 min = 444.23 N and 10 min = 470.85 N). Thermal cycling and ultrasonic instrumentation for 15 min caused a significant reduction in tensile bond strength (p < .05).