92 resultados para Cogeneration of electric power and heat
Resumo:
The optimal combination of the mechanical characteristics of austempered spheroidal graphitic cast steel together with modern casting techniques yielded an economically promising product. The maximum potentiality of the usage of these steels is related to fabrication and characterization techniques, among which, one of the most important is the cooling diagram (TTT curve). In this work, 3 heats of graphitic steels with the following nominal compositions were cast: 1.0%C, 2.3%Si, 0.4% Mn, and with niobium contents of 0.0%, 0.5% and 1.0%. TTT curves were determined by dilatometric testing and test specimens of these steels were austempered. The samples were then characterized by hardness testing and optical and SEM microscopy. Tensile, impact (no notch) and wear testing were also performed. The addition of niobium produced significant alterations in the TTT diagrams. Increasing niobium content moves the pearlite transformation nose to the right and the bainitic transformation nose to the left. Tensile strength of these alloys was high, in the range of 1700 MPa and impact values were around of 45 Joules for alloy with 1% Nb, 49 Joules for alloy with 0.5% Nb and fracture did not occur for the alloy without the addition of Nb.
Resumo:
ResumoThe main idea of this work is based on the analysis of the electric torque through the acting of the PS in the power system, provided of a control for the compensation degree (PSC). A linear model of the single machine-infinite bus system is used with a PS installed (SMIB/PS system). The variable that represents the presence of PS in the net is associated to the phase displacement introduced in the terminal voltage of the synchronous machine by PS. For the input signals of the PSC are evaluated variations of the angular speed of the rotor, the current magnitude and the active power through the line where the PS is located. The simulations are accomplished to analyze the influence of the PS in the torque formation (synchronizing and damping), of the SMIB/PS system. The analysis are developed in the time and frequency domain.
Resumo:
This paper investigates the major similarities and discrepancies of three important current decompositions proposed for the interpretation of unbalanced and/or non linear three-phase four-wire circuits. The considered approaches were the so-called FBD Theory, the pq-Theory and the CPT. Although the methods are based on different concepts, the results obtained under ideal conditions (sinusoidal and balanced signals) are very similar. The main differences appear in the presence of unbalanced and non linear load conditions. It will be demonstrated and discussed how the choice of the voltage referential and the return conductor impedance can influence in the resulting current components, as well as, the way of interpreting a power circuit with return conductor. Under linear unbalanced conditions, both FBD and pq-Theory suggest that the some current components contain a third-order harmonic. Besides, neither pq-Theory nor FBD method are able to provide accurate information for reactive current under unbalanced and distorted conditions, what seems to be done by means of the CPT. © 2009 IEEE.
Resumo:
This paper investigates the major similarities and discrepancies among three important current decompositions proposed for the interpretation of unbalanced and/or non linear three-phase four-wire power circuits. The considered approaches were the so-called FBD Theory, the pq-Theory and the CPT. Although the methods are based on different concepts, the results obtained under ideal conditions (sinusoidal and balanced signals) are very similar. The main differences appear in the presence of unbalanced and non linear load conditions. It will be demonstrated and discussed how the choice of the voltage referential and the return conductor impedance can influence in the resulting current components, as well as, the way of interpreting a power circuit with return conductor. Under linear unbalanced conditions, both FBD and pq-Theory suggest that the some current components contain a third-order harmonic. Besides, neither pq-Theory nor FBD method are able to provide accurate information for reactive current under unbalanced and distorted conditions, what can be done by means of the CPT. © 2009 IEEE.
Resumo:
In order to contribute to the discussion of defining a generalized power theory, valid for unbalanced and non linear circuits, this paper discusses the relationship and discrepancies among four modern power theories. Three-phase four-wire circuits, under different conditions, have been analyzed, since the most conflicting and intriguing interpretations take place in case of return conductor occurrence. Simulation results of different load, power supply and line conditions will be discussed in order to elucidate the author's conclusions and to provoke the readers for additional discussions. © 2010 IEEE.
Resumo:
This paper proposes a new approach for optimal phasor measurement units placement for fault location on electric power distribution systems using Greedy Randomized Adaptive Search Procedure metaheuristic and Monte Carlo simulation. The optimized placement model herein proposed is a general methodology that can be used to place devices aiming to record the voltage sag magnitudes for any fault location algorithm that uses voltage information measured at a limited set of nodes along the feeder. An overhead, three-phase, three-wire, 13.8 kV, 134-node, real-life feeder model is used to evaluate the algorithm. Tests show that the results of the fault location methodology were improved thanks to the new optimized allocation of the meters pinpointed using this methodology. © 2011 IEEE.
Resumo:
Distributed Generation, microgrid technologies, two-way communication systems, and demand response programs are issues that are being studied in recent years within the concept of smart grids. At some level of enough penetration, the Distributed Generators (DGs) can provide benefits for sub-transmission and transmission systems through the so-called ancillary services. This work is focused on the ancillary service of reactive power support provided by DGs, specifically Wind Turbine Generators (WTGs), with high level of impact on transmission systems. The main objective of this work is to propose an optimization methodology to price this service by determining the costs in which a DG incurs when it loses sales opportunity of active power, i.e, by determining the Loss of Opportunity Costs (LOC). LOC occur when more reactive power is required than available, and the active power generation has to be reduced in order to increase the reactive power capacity. In the optimization process, three objectives are considered: active power generation costs of DGs, voltage stability margin of the system, and losses in the lines of the network. Uncertainties of WTGs are reduced solving multi-objective optimal power flows in multiple probabilistic scenarios constructed by Monte Carlo simulations, and modeling the time series associated with the active power generation of each WTG via Fuzzy Logic and Markov Chains. The proposed methodology was tested using the IEEE 14 bus test system with two WTGs installed. © 2011 IEEE.
Resumo:
This paper presents the analysis of some usual MPPT (Maximum Power Point Tracking) strategies intended for small wind energy conversion (up to 1kW) based on permanent magnet synchronous generators (PMSG), considering the stand-alone application for a novel buck-boost integrated inverter. Each MPPT method is analytically introduced and then it is simulated using MatLab/Simulink considering standard conditions of wind and also commercially available turbines and generators. The extracted power in each case is compared with the maximum available power, so the tracking factor is calculated for each method. Thus, the focus is on the application to improve the efficiency of stand-alone wind energy conversion systems (WECS) with battery chargers and AC load supplied by inverter. Therefore, for this purpose a novel single phase buck-boost integrated inverter is introduced. Finally, the main experimental results for the introduced inverter are presented. © 2011 IEEE.
Resumo:
This paper presents efficient geometric parameterization techniques using the tangent and the trivial predictors for the continuation power flow, developed from observation of the trajectories of the load flow solution. The parameterization technique eliminates the Jacobian matrix singularity of load flow, and therefore all the consequent problems of ill-conditioning, by the addition of the line equations which pass through the points in the plane determined by the variables loading factor and the real power generated by the slack bus, two parameters with clear physical meaning. This paper also provides an automatic step size control around the maximum loading point. Thus, the resulting method enables not only the calculation of the maximum loading point, but also the complete tracing of P-V curves of electric power systems. The technique combines robustness with ease of understanding. The results to the IEEE 300-bus system and of large real systems show the effectiveness of the proposed method. © 2012 IEEE.
Resumo:
This paper proposes a set of performance factors for load characterization and revenue metering. They are based on the Conservative Power Theory, and each of them relates to a specific load non-ideality (unbalance, reactivity, distortion). The performance factors are capable to characterize the load under different operating conditions, considering also the effect of non-negligible line impedances and supply voltage deterioration. © 2012 IEEE.
Resumo:
Heat stress is an important cause of poor development and low survival rates in bovine embryos. Experiments were conducted to test the hypothesis that Bos indicus embryos are more resistant to heat stress than are Bos taurus embryos. In experiment 1, Nelore and Jersey embryos from oocyte pick-up-derived oocytes were submitted to heat stress (96 hours post-insemination, 41 °C, 6 hours), developmental ratios were assessed at Day 7 (Day 0 = day of fertilization), and blastocysts were frozen for RNA extraction. Experiment 2 evaluated expression of COX2, CDX2, HSF1, and PLAC8 in previously frozen blastocysts. In experiment 3, Nellore and Angus embryos from oocyte pick-up-derived oocytes were submitted to heat stress (96 hours post-insemination, 41 °C, 12 hours) and transferred to recipients on Day 7. In experiment 4, embryos developed as in experiment 3 were fixed for Terminal deoxynucleotidyl transferase dUTP nick end labeling labeling and total cell counting. In experiment 1, heat stress decreased the percentage of Jersey oocytes that became blastocysts, but had no effect on Nellore embryos (34.6%, 25.0%, 39.5%, and 33.0% for Jersey control, Jersey heat-stressed, Nellore control, and Nellore heat-stressed oocytes, respectively; P < 0.05). In experiment 2, heat stress decreased (P < 0.05) expression of CDX2 and PLAC8, with higher expression of these genes in Nellore embryos than in Jersey embryos. Heat stress also decreased (P < 0.05) expression of COX2 in Jersey embryos, but had no effect on Nellore embryos. Expression of HSF1 was decreased (P < 0.05) by heat stress in both breeds, with a greater effect in Nellore embryos. In experiment 3, heat stress tended (P = 0.1) to decrease the percentage of pregnancies among cows (Day 30 to 35) that received Angus embryos. In experiment 4, heat stress increased (P < 0.05) the percentage of apoptotic blastomeres, but had no breed-specific effects. In addition, Nellore embryos had fewer (P < 0.05) Terminal deoxynucleotidyl transferase dUTP nick end labeling- positive blastomeres than did Angus embryos. We concluded that the detrimental effects of heat stress were dependent upon embryo breed and were more evident in Bos taurus embryos than in Bos indicus embryos. © 2013 Elsevier Inc.
Resumo:
Background: The aim of this study was to compare the rates of local postoperative complications among women undergoing modified radical mastectomy with an electric scalpel (ES) or a harmonic scalpel (HS). It is thought that HS use has less postoperative complications, mainly seroma formation. Methods: This study was a prospective non-randomised clinical trial (NCT01391988) among consecutive patients, performed in parallel. Patients underwent modified radical mastectomy using an HS or ES. We analysed the following operative variables: time, blood loss and seroma volume drainage. Postoperative complications, including seroma, flap necrosis, haematoma and infection were evaluated on the 7th and 14th days. Results: Forty-six patients underwent a MRM with ES and 49 with HS; no differences were observed between the groups. The rate of local complications was 29% in the HS group and 52% in the ES group (p=0.024). The rates of seroma (16.3% versus 28.3%; p=0.161), necrosis (4.1% vs. 21.7%; p=0.013; OR=0.15), haematoma (2.0% vs. 8.7%; p=0.195) and infection (2.0% vs. 6.5%; p=0.351) were lower in the HS group. Adding the findings of all comparative studies using HSs in MRM to the seroma rates in the current study, the seroma rate, expressed as a categorical variable, did not decrease with HS. Seroma was present in 60/219 cases using an HS and in 69/239 cases utilising an ES (p=0.72). Based on a multivariate analysis, HS decreased the risk of skin necrosis (p=0.015). Conclusions: HSs do not decrease the seroma rate. However, this method may be useful in skin sparing mastectomy because it decreases skin flap necrosis. © 2013 Surgical Associates Ltd.
Resumo:
The objective of this study was to evaluate the effect of betaine in methionine- and choline-reduced diets fed to broilers submitted to heat stress. In total, 1,408 male broilers were randomly distributed into eight treatments, according to 2 × 4 (environment x diet) factorial arrangement, with eight replicates of 2 birds each. Birds were reared environmental chambers under controlled temperature (25-26 °C) or cyclic heat-stressing temperature (25-31 °C). The following diets were tested: positive control (PC), formulated to meet broiler nutritional requirements; negative control (NC), with reduced DL-methionine and choline chloride levels; and with two supplementation levels of natural betaine to the negative control diet (NC+NB1 and NC+NB2). Live performance, carcass traits, and intestinal morphometrics were evaluated when broilers were 45 days of age. The results showed that all evaluated parameters were influenced by the interaction between environment and diet, except for breast meat drip loss. The breakdown of the interactions showed that birds fed the PC diet and reared in the controlled environment had greater breast drip loss than those submitted to the cyclic heat-stress environment. Birds submitted to cyclic heat stress and fed the PC diet presented the lowest feed intake. Feed conversion ratio was influenced only by diet. The FCR of broilers fed the NC+NB2 diet was intermediate relative to those fed the PC and NC diets. The addition of betaine in the diet, with 11.18% digestible methionine and 24.73% total choline reductions, did not affect broiler live performance, carcass yield, or intestinal morphometrics.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)