110 resultados para CT reconstruction
Resumo:
The aim of this study was to evaluate the accuracy of virtual three-dimensional (3D) reconstructions of human dry mandibles, produced from two segmentation protocols (outline only and all-boundary lines).Twenty virtual three-dimensional (3D) images were built from computed tomography exam (CT) of 10 dry mandibles, in which linear measurements between anatomical landmarks were obtained and compared to an error probability of 5 %.The results showed no statistically significant difference among the dry mandibles and the virtual 3D reconstructions produced from segmentation protocols tested (p = 0,24).During the designing of a virtual 3D reconstruction, both outline only and all-boundary lines segmentation protocols can be used.Virtual processing of CT images is the most complex stage during the manufacture of the biomodel. Establishing a better protocol during this phase allows the construction of a biomodel with characteristics that are closer to the original anatomical structures. This is essential to ensure a correct preoperative planning and a suitable treatment.
Resumo:
In the world stage, the environmental condition has been a big public policies issue. A clear understanding of the parameters that determine the state of the environment is essential for estimation of the quality of life of the population, not least since ecosystems are highly complex. Consequently, definition of public policies demands the use of evaluation tools that can combine and quantify information in a clear way. The use of indicators and indices that are able to translate the complexity of environmental conditions in cities into simpler terms has been increasingly effective in decision-making, since they assist in general evaluation of the situation in question, identification of priority actions and anticipation of future trends. In an attempt to evaluate the environmental conditions of the Brazilian city, Sorocaba, an Environmental Quality Fuzzy Index (IFQAmb) was proposed. In this work this methodology is improved. After reviewing the IFQAmb methodology, a number of changes in the index are proposed. Additional variables are suggested, derived from a State Environment Department program whose objective is to grant municipalities the title of Municipio Verde e Azul (Green and Blue City). In addition, a new rule base is being drafted to enable consideration of all possibilities, since in the existing version the use of specific criteria eliminates a significant number of rules. The changes seek to define with clarity and precision the conceptual aspects and structure of the IFQAmb, so that it can provide an even more effective evaluation of environmental performance, guiding future actions in order to improve the living conditions of the population of Sorocaba.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of the present research is to analyse Ancib’s scientific production in the workgroup GT7 named Production and Communication of Information in ST&I, between the years of 2003 and 2009, through bibliometric indicators, from which it is possible to indicate what is more important or significant within a scientific field or context, so as to therefore analyse trends, existing relations or processes. The bibliometric studies are an approach method for the analysis of science behaviour in a given field. More specifically, by means of production and connection indicators, it aims at revealing and portraying the most productive authors, the kind of authorship present in this group, the most recurrent themes, most productive institutions, and the collaborative network determined by the institutional coauthorships and their indicators, so as to map and visualize the main researchers and institutions of the present GT, within the period of time in question. The research procedure derived from studying the 94 research project results presented in the period, where the paper reference, summary and corresponding key words can be found. Analysis concerning the most productive authors, most recurrent themes, kinds of authorship and most productive institutions have been carried out from the variables under review. The collaborative network between the institutions was built using the Pajek software, and, with the help of the Ucinet software, indicators of degree centrality, betweeness centrality, and closeness centrality have been reached, besides the calculation of density. The results point to 11 researchers and 9 institutions as the most productive ones. The collaborative institutional network was shown to be fragile, presenting low density, and in general the participating institutions have presented low centrality indexes. As a conclusion, it has been observed that the themes focus, in general, on bibliometric analysis and their indicators, using regional and national data as their universe.
Resumo:
Background: We aimed to establish values and parameters using multislice reconstruction in axial computerized tomography (CT) in order to quantify the erosion of the glenoid cavity in cases of shoulder instability. Methods: We studied two groups using CT. Group I had normal subjects and Group II had patients with shoulder instability. We measured values of the vertical segment, the superior horizontal, medial and inferior segments, and also calculated the ratio of the horizontal superior and inferior segments of the glenoid cavity in both normal subjects and those with shoulder instability. These variables were recorded during arthroscopy for cases with shoulder instability. Results: The mean values were 40.87 mm, 17.86 mm, 26.50 mm, 22.86 mm and 0.79 for vertical segment, the superior horizontal, medial and inferior segments, and the ratio between horizontal superior and inferior segments of the glenoid cavity respectively, in normal subjects. For subjects with unstable shoulders the mean values were 37.33 mm, 20.83 mm, 23.07 mm and 0.91 respectively. Arthroscopic measurements yielded an inferior segment value of 24.48 mm with a loss of 2.39 mm (17.57%). The ratio between the superior and inferior segments of the glenoid cavity was 0.79. This value can be used as a normative value for evaluating degree of erosion of the anterior border of the glenoid cavity. However, values found using CT should not be used on a comparative basis with values found during arthroscopy. Conclusions: Computerized tomographic measurements of the glenoid cavity yielded reliable values consistent with those in the literature.
Resumo:
The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity. In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series h(t) from the detector signals is described. The standard consistency checks of the reconstruction are discussed and used to estimate the systematic uncertainties of the h(t) signal as a function of frequency. Finally, an independent setup, the photon calibrator, is described and used to validate the reconstructed h(t) signal and the associated uncertainties. The systematic uncertainties of the h(t) time series are estimated to be 8% in amplitude. The uncertainty of the phase of h(t) is 50 mrad at 10 Hz with a frequency dependence following a delay of 8 mu s at high frequency. A bias lower than 4 mu s and depending on the sky direction of the GW is also present.
Resumo:
A description is provided of the software algorithms developed for the CMS tracker both for reconstructing charged-particle trajectories in proton-proton interactions and for using the resulting tracks to estimate the positions of the LHC luminous region and individual primary-interaction vertices. Despite the very hostile environment at the LHC, the performance obtained with these algorithms is found to be excellent. For t (t) over bar events under typical 2011 pileup conditions, the average track-reconstruction efficiency for promptly-produced charged particles with transverse momenta of p(T) > 0.9GeV is 94% for pseudorapidities of vertical bar eta vertical bar < 0.9 and 85% for 0.9 < vertical bar eta vertical bar < 2.5. The inefficiency is caused mainly by hadrons that undergo nuclear interactions in the tracker material. For isolated muons, the corresponding efficiencies are essentially 100%. For isolated muons of p(T) = 100GeV emitted at vertical bar eta vertical bar < 1.4, the resolutions are approximately 2.8% in p(T), and respectively, 10 m m and 30 mu m in the transverse and longitudinal impact parameters. The position resolution achieved for reconstructed primary vertices that correspond to interesting pp collisions is 10-12 mu m in each of the three spatial dimensions. The tracking and vertexing software is fast and flexible, and easily adaptable to other functions, such as fast tracking for the trigger, or dedicated tracking for electrons that takes into account bremsstrahlung.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Selective neck dissection (SND) in clinical N-0 (cN(0)) cases of oral squamous cell carcinoma (SCC) has been performed by surgeons using a retroauricular or modified facelift approach with robotic or endoscopic assistance. However, these procedures provide cosmetic satisfaction at the cost of possible maximal invasiveness. In this prospective study, we introduced and evaluated the feasibility as well as surgical invasiveness and cosmetic outcome of endoscopically-assisted SND via a small submandibular approach.Forty-four patients with cT(1-2)N(0) oral SCC (OSCC) were randomly divided into two groups of endoscopically-assisted SND and conventional SND. Perioperative and postoperative outcomes of patients were evaluated, including the length of the incision, operating time for neck dissection, estimated blood loss during the operation, amount and duration of drainage, total hospitalization period, total number of lymph nodes retrieved, satisfaction scores based on the cosmetic results, perioperative local complications, shoulder syndrome, and follow-up information.The mean operation time in the endoscopically-assisted group (126.04 +/- A 12.67 min) was longer than that in the conventional group (75.67 +/- A 16.67 min). However, the mean length of the incision was 4.33 +/- A 0.76 cm in the endoscopically-assisted SND group, and the amount and duration of drainage, total hospital stay, postoperative shoulder pain score, and cosmetic outcomes were superior in the endoscopically-assisted SND group. Additionally, the retrieved lymph nodes and complications were comparable.Endoscopically-assisted SND via a small submandibular approach had a longer operation time than the conventional approach. However, endoscopically-assisted SND was feasible and reliable while providing minimal invasiveness and satisfactory appearance.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)