216 resultados para AH plus


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction The aim of this study was to compare the effect of QMix, BioPure MTAD, 17 % EDTA, and saline on the penetrability of a resin-based sealer into dentinal tubules using a confocal laser scanning microscope (CLSM) and to describe the cleaning of root canal walls by SEM. Methods Eighty distobuccal roots from upper molars were selected and randomly divided into four groups (n=20) before root canal preparation according to the solution used in the final rinse protocol (FRP): QG (QMix), MG (BioPure MTAD), EG (17 % EDTA), and CG (control group: saline). Ten roots of each group were prepared for SEM, and images (×2000) from the canal walls were acquired. The remaining canals were filled with a single gutta-percha cone and AH Plus with 0.1 % Rhodamine B. The specimens were horizontally sectioned at 4 mm from the apex, and the slices were analyzed in CLSM (×10). Sealer penetration was analyzed with Adobe Photoshop software. Results QG and EG presented similar amounts of sealer penetration (P>.05). MG and CG presented the lowest penetrability values (P<.05). The best results for smear layer removal of the apical third of the root canal were achieved by the QG and EG groups when compared with MG and CG (P<.05). Conclusions Seventeen percent EDTA and QMix promoted sealer penetration superior to that achieved by BioPure MTAD and saline. Clinical relevance Despite studies have not confirmed the relationship between sealing ability of endodontic sealers and their penetration in dentinal tubules, sealer penetration assumes importance, since endodontic sealers, unlike guttapercha, are able to penetrate in dentinal tubules, isthmus, and accessory canals, filling the root canal system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10mm in diameter and 1mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determine the radiopacity equivalence in millimeters of aluminum. To evaluate the flow, a 120 g load was placed on top of a glass slab containing 0.05 } 0.005ml of sealer. The diameters of each material were measured (mm) with a caliper and samples were photographed. Digitized images were analyzed using the UTHSCSA Image Tool for Windows software, to determine the sealer area (mm2). Data were submitted to ANOVA and Tukey's test at 5% significance. AH Plus and Epiphany SE presented the greatest radiopacity (12.5 mm Al and 12.0 mm Al, respectively) (p>0.05), followed by Epiphany (9.6 mm Al) and Fillapex (8.9 mm Al). Endo CPM (5.46 mm Al) and Sealapex (5.51 mm Al) presented lower radiopacity. MTA Fillapex presented significantly higher values of flow than other sealers (33.11 mm and 844.9 mm2). AH Plus, Epiphany, and Epiphany SE had similar values. Endo CPM (21.05 mm and 342.8 mm2) and Sealapex (19.98 mm and 352.5 mm2) presented the lowest flow values (p>0.05). All sealers presented radiopacity and flow values according to ISO and ANSI/ADA recommendations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to characterize and to evaluate the bioactivity potential of experimental root canal sealers (ES) based on Portland cement, epoxy resin with nano- and micro-particles of niobium or zirconium oxide used as radiopacifiers in comparison to AH Plus and MTA Fillapex. Methods Specimens of the sealers (10 mm in diameter × 1 mm thick) were prepared and the radiopacity was evaluated according to ISO 6876 (2012) specifications. Characterization of the sealers was performed under the scanning electron microscope (SEM) immediately after setting and after immersion for 28 days in Hank's balanced salt solution (HBSS). In addition X-ray energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy were also performed. The pH and calcium ion release were measured after 1, 7, 14, 21 and 28 days after completion of seating using a digital pH meter and an atomic absorption spectrophotometer, respectively. Results The experimental sealers exhibited an average radiopacity of 2.5 mm thickness of aluminum, which was similar to MTA Fillapex (P > 0.05) and inferior to AH Plus (P < 0.05). AH Plus did not show bioactivity. Although the experimental sealers did not exhibit the formation of hydration product, they encouraged the deposition of crystalline spherical structures of calcium deficient phosphate. The highest pH and calcium release values were observed with the experimental sealers (P < 0.01). ES-Nb-micro was the only sealer to present hexagonal shaped crystal deposition. Significance Novel root canal sealers based on a mixture of Portland cement, epoxy resin and radiopacifier exhibited a degree of bioactivity although no evidence of cement hydration was demonstrated on material characterization. The radiopacifier particle size had limited effect on the sealer microstructure and chemical properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The antimicrobial activity is a fundamental property of root-canal sealers due to persistence of residual microorganisms in the root canal system, even after the chemo-mechanical preparation and using of intracanal dressing. The aim of this study is to review the literature about the antimicrobial properties of some of the main root-canal sealers. Although there is controversy regarding this property, probably due to differences in the methodologies used in the studies, it was concluded that the sealers with the best antimicrobial activity were (in ascending order): Endofill, Ketac Endo, Sealapex, AH Plus, Endo CPM Sealer, Sealer 26 and Epiphany. Activ GP still needs scientific research to evaluate this property.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three assays were carried out to determine the digestible methionine+cystine (Met+Cys) requirement for ISA Label broilers from both sexes. The birds were reared in free range system on starting phase (1 to 28 days), growing phase (28 to 56 days) and finishing phase (56 to 84 days). Four hundred and eighty birds were distributed into 24 pens, each one composed of shelter (3.13 m(2)) and pasture (72.87 m(2)). The experimental design was completely randomized with eight treatments as factorial arrangement (four Met+Cys levels and two sexes) with three replicates of 20 birds. The digestible Met+Cys levels were 0.532; 0.652; 0.772; 0.892% for starting phase; 0.515; 0.635; 0.755; 0.875% for growing phase and 0.469; 0.589; 0.709; 0.829% for finishing phase. The analyzed parameters were performance, carcass yield, body protein and fat deposition, weight and protein concentration in feathers. In the starting phase, the digestible Met+Cys level estimated for males was 0.765 and 0.803% for females, corresponding to 0.252 and 0.268% of Met+Cys/Mcal of ME, respectively. For the growing phase, the digestible Met+Cys level estimated was 0.716% for both sexes, corresponding to 0.235% of Met+Cys/Mcal of ME. For the finishing phase, the Met+Cys levels were 0.756 and 0.597% for males and females, corresponding to 0.244 and 0.193% of Met+Cys/Mcal of ME respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to evaluate the efficacy of the formulated mixture clomazone and hexazinone applied in soil or combined with sugarcane mulch, after different periods of permanence without the occurrence of rain. The experiment was carried out in vases under greenhouse conditions in Botucatu, São Paulo, Brazil. The weeds Brachiaria decumbens, Ipomoea grandifolia, Ipomoea hederifolia and Euphorbia heterophylla were sown and covered or not with sugarcane mulch. The experiment was arranged in a complete randomized design with four repetitions. The treatments were displaced in a 3x6 factorial scheme, with the factors being six periods without rain (0, 3, 7, 15, 30, and 60 days) and three modes of herbicide application(on the soil without sugarcane mulch, on and under sugarcane mulch). Control evaluations were carried out at 10, 21, 35 and 42 days after the occurrence of rain. The clomazone + hexazinone mixture promoted an excellent weed control for all the species studied when applied on, under, or without sugarcane mulch. However, the control levels tended to reduce for periods over 60 days without rain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We conducted a longitudinal study about daily variation of Wistar male rats' behavior in the elevated plus-maze (EPM) evaluated in the 1st, 2nd, 3rd, 6th, 12th, and 18th months of life. Animals were submitted to the plus-maze in 12 sessions at 2-h intervals (n=72, 6 per time point). Spontaneous rest-activity rhythm of four animals was assessed by observation of 24-h videotape records. Time series were analyzed by Cosinor method. Behavioral rates on the six occasions and in light and dark phases were compared by means of two-way ANOVA with repeated measures. Exploratory behavior in EPM was smaller in the light phase and in older animals. Higher values of open and closed arms exploration were observed in the first and third months of the dark phase, and in the first month of the light phase. Adjustment to the 24-h period was significant at all stages for rest-activity data, number of entries in closed arms, and time on center, and for three to five stages for open-arm exploration. In general, 24 h variability was more pronounced in younger animals compared with older ones. The present study showed that: (1) a significant amount of total variability of the behavioral indexes analyzed could be attributed to 24 h variation, (2) light/dark phases differences in EPM exploration were present at all developmental stages, (3) older Wistar rats explored less the EPM and were less active in their home cage compared with younger ones, and (4) behavioral indexes (EPM) decrease was phase related and partially related to a reorganization of rest-activity rhythm. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyzed the accuracy/agreement of the Omron MX3 monitor on 165 adolescents. Blood pressure was measured by the automatic monitor connected in Y with the mercury column (three consecutive and simultaneous measures). The independent measures were analyzed, and the mean differences between systolic and diastolic measures for both methods were calculated and compared with British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) criteria. The automatic monitor received the highest degree of BHS recommendations for systolic and diastolic blood pressures according to the BHS. The median (25th and 75th) difference between the observer and the monitor measurements was -2 (-6 and 1) mmHg for systolic and 0 (-3 and1) mmHg for diastolic pressures. The monitor also satisfies the AAMI standard for the studied population. In conclusion, the Omron MX3 Plus monitor can be considered reliable and valid for clinical practice and is in accordance with BHS and AAMI criteria.