169 resultados para urban water bodies


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present work had the objective to elaborate the map of land use and vegetation covering from Tijuco river watershed, Ituiutaba-MG, based on digital images obtained by satellite from CBERS 2, through automatic delimitation of permanent preservation areas followed by identification of land use conflict based on the Brazilian Forest Code (Law no 4771/1965) and National Council of Environment's Resolution no 303/02. This paper analyzes, through quantitative parameters and the use of Geographic Information System, the maintenance tracks of width recommended by the legislation for permanent preservation areas over water bodies. The results showed a deficit of conserved areas along the riverbanks of 2334 ha that are not in compliance with the legislation. The pasture occupies unduly 0.97% of the area of the basin in the permanent preservation areas at the riverbanks, while agriculture occupies 0.38%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study evaluated using of Multicriteria Evaluation in a GIS, specifically by Weighted Linear Combination Method for generation of map of priority areas for forest restoration in the initial part of River Pardo Basin, SP, in order to water resources conservation. Aiming to define criteria and restrictions it was used Participatory Techniques, and the following factors had been selected: proximity of the hydrographic network, proximity of forest cover, slope and erodibility of soil. To calculate the weight to each factor it was used the decision-making process, known as Analytic Hierarchy Analysis, this method consists of a paired comparison of factors to determine the relative importance of each. According to Weighted Linear Combination, the very high priority areas have a more limited spatial distribution, with an apparent concentration around the water bodies, outlining a buffer to the river system. The proximity factor of the hydrographic network, and enables the connection forestry, contributed, along with the factor of proximity to forest cover, so there would be the definition of most of the areas with the highest priority in the basin, which concentrate the largest areas of forest and native riparian areas along the hydrographic.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Urease inhibitor (UI) and nitrification inhibitor (NI) have the potential to improve N-use efficiency of applied urea and minimize N losses via gaseous emissions of ammonia (NH 3) to the atmosphere and nitrate (NO3-) leaching into surface and ground water bodies. There is a growing interest in the formulations of coating chemical fertilizers with both UI and NI. However, limited information is available on the combined use of UI and NI applied with urea fertilizer. Therefore the aim of this study was to investigate the effects of treating urea with both UI and NI to minimize NH 3 volatilization. Two experiments were set up in volatilization chambers under controlled conditions to examine this process. In the first experiment, UR was treated with the urease inhibitor NBPT [N-(n-butyl) thiophosphoric acid triamide] at a rate of 1060 mg kg -1 urea and/or with the nitrification inhibitor DCD (dicyandiamide) at rates equivalent to 5 or 10% of the urea N. A randomized experimental design with five treatments and five replicates was used: 1) UR, 2) UR + NBPT, 3) UR + DCD 10%, 4) UR + NBPT + DCD 5%, and 5) UR + NBPT + DCD 10%. The fertilizer treatments were applied to the surface of an acidic Red Latosol soil moistened to 60% of the maximum water retention and placed inside volatilization chambers. Controls chambers were added to allow for NH 3 volatilized from unfertilized soil or contained in the air that swept over the soil surface. The second experiment had an additional treatment with surface-applied DCD. The chambers were glass vessels (1.5 L) fit with air inlet and outlet tubings to allow air to pass over the soil. Ammonia volatilized was swept and carried to a flask containing a boric acid solution to trap the gas and then measured daily by titration with a standardized H 2SO 4 solution. Continuous measurements were recorded for 19 and 23 days for the first and second experiment, respectively. The soil samples were then analyzed for UR-, NH4+-, and NO3--N. Losses of NH 3 by volatilization with unamended UR ranged from 28 to 37% of the applied N, with peak of losses observed the third day after fertilization. NBPT delayed the peak of NH 3 losses due to urease inhibition and reduced NH 3 volatilization between 54 and 78% when compared with untreated UR. Up to 10 days after the fertilizer application, NH 3 losses had not been affected by DCD in the UR or the UR + NBPT treatments; thereafter, NH 3 volatilization tended to decrease, but not when DCD was present. As a consequence, the addition of DCD caused a 5-16% increase in NH 3 volatilization losses of the fertilizer N applied as UR from both the UR and the UR + NBPT treatments. Because the effectiveness of NBPT to inhibit soil urease activity was strong only in the first week, it could be concluded that DCD did not affect the action of NBPT but rather, enhanced volatilization losses by maintaining higher soil NH4+ concentration and pH for a longer time. Depending on the combination of factors influencing NH 3 volatilization, DCD could even offset the beneficial effect of NBPT in reducing NH 3 volatilization losses. © 2012 Elsevier Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Anaerobic digestion applied to stillage usually results in treatment performances. However, effluents from anaerobic reactors still present a residual polluting load due to the presence of organic recalcitrant compounds. Additional treatment methods, such as coagulation-flocculation, may be utilized to improve the final effluent quality. In this study, we assessed the processes of coagulation and flocculation for sugarcane stillage samples previously submitted to anaerobic digestion, aiming to obtain optimal conditions for the physicochemical treatment. Natural corn starch and ferric chloride were tested as coagulants. While starch was considered as not suitable for the treatment for the tested conditions, ferric chloride assays presented satisfactory results. The investigated parameters included coagulant solution dose, rapid mixing gradient and time, flocculation gradient and time, and sedimentation time. Their adjusted values at which better performances obtained were, respectively, 1.6 g L-1, 325 rpm, 10 s, 65 rpm, 20 and 20 min. The best color, turbidity, and chemical oxygen demand removal efficiencies were 95, 97, and 65%, respectively. Stillage pH variation to alkaline conditions did not result in improved removal efficiencies. Although relatively high removal efficiencies of constituents were obtained, the final effluent characteristics did not fit regulations of water reuse in the agriculture through fertigation. However, stillage can definitely become more easily managed if better final effluent quality control parameters are achieved, enabling for example effluents discharge in water bodies. © 2013 Copyright Balaban Desalination Publications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We prepared a W/WO3/TiO2 bicomposite photoanode by simple electrochemical anodization of W foil, followed by cathodic electrodeposition of TiO2 and annealing at 450 C for 30 min. This photoanode shows good photoactivity under irradiation with UV and visible light. In optimized conditions, it promotes complete photoelectrocatalytic oxidation of 3.33 × 10-5 mol L-1 basic red 51 solution (which is used in hair dye) at 0.1 mol L-1 Na2SO4, pH 2.0, under a current density of 1.25 mA cm-2 and ultraviolet and visible radiation-total organic carbon removal is 94 and 88%, respectively. This effect paves the way for the sustainable solar-assisted remediation of water bodies contaminated with organic components of hair dyes. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The wastewater discharge produces impacts on receiving water bodies. Nutrients as P produce implications on lentic systems because they accelerate the eutrophication processes. Several technologies for P removal from the wastewater have been used: physic chemical treatment systems with important effects by coagulant products addition; biological processes based on anaerobic and aerobic conditions with great implications on the required volume; natural systems as stabilization ponds and irrigation require bigger areas and post-treatment processes. The aerobic fluidized bed reactors with internal circulation (AFBRIC) are compact options with high concentrations of active biomass that have demonstrated their capacity for organic matter and N removal. For sewage from the wastewater pumping station of Ilha Solteira city and effluents of a recirculation aquaculture system (RAS) for semi-intensive tilapia farming, the reactive P and total P removal efficiency in three AFBRIC with 250 mm external tube diameter and different internal tube diameter (ITD), for two different support media at different concentrations was evaluated. The average reactive P removal efficiency for domestic wastewater to hydraulic retention time (HRT) of 3 hours and 125 mm ITD reactor varied from 25,6 to 38,4% and with 150 mm ITD reactor varied from 27,5 to 32,5%; the average total P removal for the RAS wastewater at a HRT of 0,19 hours and 100 mm ITD was of 32,7%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The inadequate and indiscriminate disposal of sugarcane vinasse in soils and water bodies has received much attention since decades ago, due to environmental problems associated to this practice. Vinasse is the final by-product of the biomass distillation, mainly for the production of ethanol, from sugar crops (beet and sugarcane), starch crops (corn, wheat, rice, and cassava), or cellulosic material (harvesting crop residues, sugarcane bagasse, and wood). Because of the large quantities of vinasse produced, alternative treatments and uses have been developed, such as recycling of vinasse in fermentation, fertirrigation, concentration by evaporation, and yeast and energy production. This review was aimed at examining the available data on the subject as a contribution to update the information on sugarcane vinasse, from its characteristics and chemical composition to alternatives uses in Brazil: fertirrigation, concentration by evaporation, energy production; the effects on soil physical, chemical and biological properties; its influence on seed germination, its use as biostimulant and environmental contaminant. The low pH, electric conductivity, and chemical elements present in sugarcane vinasse may cause changes in the chemical and physical-chemical properties of soils, rivers, and lakes with frequent discharges over a long period of time, and also have adverse effects on agricultural soils and biota in general. Thus, new studies and green methods need to be developed aiming at sugarcane vinasse recycling and disposal. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Brazilian government has been encouraging fish farming in cages in federal water bodies, including hydroelectric reservoirs. Despite the government support, it is a new activity and the production model still needs some adjustment to reduce the production costs and achieve sustainability. The aims of this study were to determine the appropriate stocking density of Nile tilapia in cages in a hydroelectric reservoir and to evaluate to what extent fish size selection could improve their uniformity. Twelve cages (6m3) were placed at the Fish Farmers' Cooperative of Santa Fé do Sul and Region, Ilha Solteira reservoir, São Paulo, Brazil (20°12'10″S, 50°58'31.15″W). In stage I (initial fish weight, 78g), four stocking densities were tested: D1-800, D2-2000, D3-2500 and D4-3000 fish/cage, with three replicates. At the end of this stage (average fish weight, 255g), the fish were selected into three sizes, except for D1. In stage II, four stocking densities were tested, designed to obtain the following final production: D1-100kg/m3 (800 non-selected fish/cage), D2-80kg/m3 (600 fish/cage), D3-100kg/m3 (800 fish/cage) and D4-120kg/m3 (900 fish/cage). The trial ended when the fish weighed 800g. By reducing the initial stocking density from 2500 to 800 tilapia juveniles per cage, there was no need for selection. The growth performance was higher, the feed conversion rate was better and the time taken to reach harvesting was shorter. Consequently, the production cost reduced and the operating profit increased. Using the lowest initial stocking density, the risk of disease outbreak was also lower, and there was no need to use drugs for disease control since the mortality rate and occurrences of disease and deformity decreased and the dissolved oxygen level inside the cages was higher. © 2013 Elsevier B.V.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Biologia Animal - IBILCE