101 resultados para thermal comfort index
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Geografia - FCT
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Poultry facilities must provide an environment that ensures thermal comfort allowing the animal to express its genetic potential for production; and new tools are being applied to measure the thermal comfort, especially thermal cameras. The objective of this study was to evaluate the association of the surface temperature of the birds with those from the facilities, and estimate the sensible heat transfer. For this, the thermal conditions of rearing in two aviaries with different ventilation systems, during the period of March to April 2011 were recorded. The aviaries were divided into six quadrants for the registration of surface temperatures obtained using an infrared thermal camera. In each quadrant the ambient temperature, relative humidity and wind velocity during the obtention of images were also recorded. It was observed that the surface temperatures of birds are associated with the surface temperature of the rearing facilities (side curtains, roof and litter). In aviary with negative pressure higher wind speeds compared to the conventional one were recorded and; therefore, allowed a higher sensible heat transfer by birds, suggesting that this provided better conditions for thermal comfort.
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
This study consists in the observation and evaluation of the thermal behavior and distribution of wood composite walls, MDF – Medium Density Fiberboard, HDF – High Density Fiberboard, OSB – Oriented Strand Board and EGP – Edge Glued Panel. This study had the objective to present the experimental thermal behavior and to verify which one fit the thermal comfort standards for human labor For this work, was developed a thermal chamber, with one interchangeable side, so the wall prototypes would fit for each experiment. We studied walls made of MDF, HDF, OSB and EGP, which one had its own distinct behavior due to the panel construction. The EGP wall had shown the most reliable material for this usage at high temperatures. With this work, it was demonstrated the importance of choice for the right material and construction method for wooden composite walls, because if they were scaled poorly, the people exposed to them would be uncomfortable by the proportionate environment, and the costs for a resizing would be too high
Resumo:
The discussions about the energy rationalization are gaining more and more space on the everyday of engineers and other professionals in the field of energy. A greater focus is being tied to commercial buildings, because they are one of the biggest responsible for the high energetic expenditure according to the National Energetic Balance, especially by the use of air conditioners for the people’s thermal comfort. Such finding made INMETRO to develop a building labeling procedure through th National Program of Electric Energy Conservation in Buildings; by means of this systematic, the built areas are classified by levels that go from A(the best) to E(the worst), taking into account envelopment, illumination system and air conditioning. A bonus process based on water rationalization, use of renewable energy sources, cogeneration systems or technical innovations, allows the classification to be changed up to one level. A study made exactly on a commercial building, the building of Foundation for Technological and Scientific Development located inside of the College of Engineering of Guaratinguetá, sought to identify technical/economic alternatives for the building certification and appealed to the bonus based on water rationalization. The present study is based on analysis of deploying a cogeneration system formed by internal combustion engine and an absorption refrigeration system as bonus alternative, so that the costs are analyzed regarding energy consumption and use of the motor. With the calculations and results, the viability of the building to receive a bonus from INMETRO through its National Program for Energy Conservation in Buildings is studied and concluded from this study whether or not you can get a better level of energy efficiency for the building in question... (Complete abstract click electronic access below)
Resumo:
This work deals with the thermal load study of a fictitious aircraft as well as scaling, in terms of the airflow and temperature of the air conditioning system, for heating and cooling of the its internal environment, aiming the thermal comfort of occupants. The first part is presented the techniques and methods utilized for modeling different heat exchanges that occur in the aircraft and then allowed to calculate the total heat load and the airflow and temperature necessary to comply with the requirements of the thermal comfort. Techniques to determine the basic parameters, as convection coefficient and global coefficient of heat exchange, are also presented. The work aims to develop a program, using a computational tool, to automate the calculations so that facilitate this study. It also allows to be used for other airplanes just changing parameters and the control variables related to the specific project. Finally the program performs calculations for a fictitious airplane, to analyze its functionality and the influence of parameters involved in the temperature controls. The program allowed analyzing the sensitivity of portions of the thermal load and the corresponding parameters of influence, as well as the scaling of the air conditioning in terms of airflow and temperature. It was considered, despite the simplifications, a good approximation to the actual values and then can be used in development of the other airplanes
Resumo:
This research aimed to analyze the spatial area for the design of the Heat Island of Subprefecture Sé, in São Paulo-SP, with the support of geotecnology and based on the study of environmental perception. We used remote sensing products such as maps ofland use and soil temperature and apparent surface to evaluate the thermal conditions considered critical points in the central area of the municipality. The methodology used was qualitative analysis, based on interviews with the people, allowing rescue geoecology the conditioning aspects of the city, with an emphasis on environmental perception. This study aimed toanalyze the perception of the variation of the thermal field in São Paulo. The results indicated that (95%) of respondents feel that the temperature of the central area has increased each year, and the district that stood out was the Sé, due to intense use and occupation of land and contribute one of the largest shopping centers. Districts with points given for having better thermal comfort were Santa Cecília, the República and Bela Vista, due to their larger amount of green areas by fiscal court, which act as local refrigerators. It was found that the respondents have the perception and awareness of their spa directly related to the quality of life. Through analysis of several variables involved, proposals and strategies may support public policies and urban planning
Resumo:
Mirandópolis/SP appeared in 1934 from the railroad “the Brazil Northwest”, that there it served one of the points of its stretch that had as main function to drain the agricultural production northwestern native of São Paulo of that time. The installation of the town happened absent of concerns with initial urbanístico planning, thus modifying its natural landscape and modifying characteristic ambient without compensatory measures aiming at a future expansion of the urban mesh. Fact this that still causes today consequences the quality of life of the people and also the observed thermal comfort later. Ahead of this, the present work had for objective to identify through measurements of temperature and relative humidity of the city of Mirandópolis/SP the differences that in the fabric urban they corroborate for a comfort situation or thermal discomfort to the outdoors in accordance with the Diagram Bioclimático de Olgyay the collection of data was made throughout the month of July of 2011 involving the attainment of information of Temperature and relative humidity of air and questionnaire applied to the passer-bys in the act of the measurements. Also approaching the different thermal dynamic of the zones of housing in relation to the Urban Cannyon that develops the commerce as predominant activity. This research sample that, although a city to be small, the quality of life of its inhabitants is not only guaranteed by the transport or that its thermal comfort reveals inside homogeneous of the urban perimeter, but that it has yes heterogeneidade in the scope of the urban climate in these spaces
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This study was conducted to determine the effect of the air temperature variation on the mean surface temperature (MST) of 7-to 35-day-old broiler chickens using infrared thermometry to estimate MST, and to study surface temperature variation of the wings, head, legs, back and comb as affected by air temperature and broiler age. One hundred Cobb(R) broilers were used in the experiment. Starting on day 7, 10 birds were weekly selected at random, housed in an environmental chamber and reared under three distinct temperatures (18, 25 and 32 degrees C) to record their thermal profile using an infrared thermal camera. The recorded images were processed to estimate MST by selecting the whole area of the bird within the picture and comparing it with the values obtained using selected equations in literature, and to record the surface temperatures of the body parts. The MST estimated by infrared images were not statistically different (p > 0.05) from the values obtained by the equations. MST values significantly increased (p < 0.05) when the air temperature increased, but were not affected by bird age. However, age influenced the difference between MST and air temperature, which was highest on day 14. The technique of infrared thermal image analysis was useful to estimate the mean surface temperature of broiler chickens.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG