145 resultados para synchronization protocols
Resumo:
Cancer development is a long-term multistep process which allows interventional measure before the clincial disease emerges. the detection of natural substances which can block the process of carcinogenesis is a important as the identification of anti-tumoral drugs since they might be used in chemoprevention of cancer in high-risk groups. In vivo rodent models of chemical caecinogenesis have been used to study plant-derived inhibitors of carcinofenesis such as indols, coumarins, isothiocyanates, flavones, phenols and allyl-sulfides. Since the standard in vivo rodent bioassay is prolonged and expensive, shorter reliable protocols are needed. Two in vivo medium-term protocols for evaluation of modifiers of carcinogenesis are presented, one related to liver and the other to bladder cancer. Both protocols use rats, last 8 and 36 weeks and are based on the two-step concept of carcinogenesis: initiation and promotion. The protocols use respectively the development of altered foci of hepatocytes expressing immunochistochemically the placental form of gluthation S-transferase and the appearence of pre-neoplastic urothelium and papillomas as the end-points. the use of these protocols for detection of plantpderived inhibitors of carcinogenesis appear warranted.
Resumo:
Avaliou-se a eficácia da dose de 0,10 ou de 0,25mg de gonadorelina nas taxas de ovulação e de sincronização no protocolo Ovsynch e de 150mcg de D-cloprostenol ou 0,530mg de cloprostenol sódico na regressão do corpo lúteo (CL) de sete dias e de todos os CL. Foram utilizadas 136 vacas lactantes da raça Holandesa, com média de produção de leite de 23,75,8kg/dia, com 138,4±72,0 dias em lactação. As vacas foram distribuídas aleatoriamente em quatro grupos, de acordo com a dose de gonadorelina e o tipo da prostaglandina. As taxas de ovulação e de sincronização foram de 52,9% e 80,9% para 0,10mg de gonadorelina e de 57,4% e 80,9% para 0,25mg de gonadorelina, respectivamente. A taxa de regressão do CL de sete dias foi de 97,1% para o D-cloprostenol e de 97,5% para o cloprostenol sódico. A taxa de prenhez não foi influenciada pelos tratamentos, mas foi influenciada pela taxa de ovulação à primeira aplicação de gonadorelina, 16,0% vs. 6,6% para as vacas que ovularam e não ovularam, respectivamente. Conclui-se que 0,10mg de gonadorelina foi eficiente e ambas prostaglandinas podem ser usadas em protocolos de sincronização da ovulação.
Resumo:
O objetivo deste trabalho foi desenvolver protocolo eficiente e reprodutível de imunização em cobaias com antígenos de P. brasiliensis, visando a obtenção de modelo experimental para futuros estudos de mecanismos de proteção imunológica. Testaram-se três diferentes antígenos (particulado, solúvel e composto) e seis protocolos nos quais foram avaliadas as influências dos seguintes fatores: presença ou ausência de adjuvante completo de Freund, número de doses imunizantes e intervalo de tempo entre a última dose imunizante e o desafio. A eficiência do protocolo de imunização foi estudada pela avaliação da resposta imune celular e humoral anti-P. brasiliensis, utilizando teste cutâneo e teste de inibição da migração do macrófago, e imunodifusão, respectivamente. Observou-se que: 1. Três doses imunizantes de antígeno induziram melhor resposta do que duas doses; 2. Maior resposta imune foi conseguida com a utilização de adjuvante completo de Freund; 3. Animais desafiados depois de longo tempo (6 semanas) da última dose imunizante mostraram melhor resposta imune anti-P. brasiliensis; 4. Os antígenos solúvel e composto foram igualmente eficientes induzindo maior resposta imune humoral e celular anti-P. brasiliensis enquanto que o antígeno particulado provocou menor reatividade
Resumo:
The lactate minimum test (LACmin) has been considered an important indicator of endurance exercise capacity and a single session protocol can predict the maximal steady state lactate (MLSS). The objective of this study was to determine the best swimming protocol to induce hyperlactatemia in order to assure the LACmin in rats (Rattus norvegicus), standardized to four different protocols (P) of lactate elevation. The protocols were PI: 6 min of intermittent jumping exercise in water (load of 50% of the body weight - bw); P2: two 13% bw load swimming bouts until exhaustion (thin); P3: one thin 13% bw load swimming bout; and P4: two 13% bw load swimming bouts (1st 30 s, 2nd to thin), separated by a 30 s interval. The incremental phase of LACmin beginning with initial loads of 4% bw, increased in 0.5% at each 5 min. Peak lactate concentration was collected after 5, 7 and 9 min (mmol L-1) and differed among the protocols P 1 (15.2 +/- 0.4, 14.9 +/- 0.7, 14.8 +/- 0.6) and P2 (14.0 +/- 0.4, 14.9 +/- 0.4, 15.5 +/- 0.5) compared to P3 (5.1 +/- 0.1, 5.6 +/- 0.3, 5.6 +/- 0.3) and P4 (4.7 +/- 0.2, 6.8 +/- 0.2, 7.1 +/- 0.2). The LACmin determination success rates were 58%, 55%, 80% and 91% in P1, P2, P3 and P4 protocols, respectively. The MLSS did not differ from LACmin in any protocol. The LACmin obtained from P4 protocol showed better assurance for the MLSS identification in most of the tested rats. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Sepsis is a syndrome characterized by infection and generalized inflammatory response that can lead to organ failure and death. In this study we standardize a model to investigate acupuncture's effects upon sepsis. The objectives were to study the use of acupuncture in the infectious process and to formulate acupuncture's treatment protocol for sepsis. The CLP (cecal ligation and puncture) model in rats was used to induce sepsis through bacterial entrance into the peritoneal cavity. An acupuncture treatment protocol that enhanced survival and reversed the neutrophil impairment migration toward the peritoneal cavity in rats with sepsis was achieved. It seems that acupuncture can be used for the treatment of experimental infectious processes. The effects of acupuncture and related mechanisms are discussed.
Resumo:
Recently a protocol was developed that precisely synchronizes the time of ovulation in lactating dairy cows (Ovsynch; GnRH-7d-PGF(2 alpha)-2d-GnRH). We evaluated whether initiation of Ovsynch on different days of the estrous cycle altered the effectiveness of this protocol. The percentage of cows (n=156) ovulating to the first GnRH was 64% and varied (P<0.01) by stage of estrous cycle. Treatment with PGF(2 alpha) was effective, with 93% of cows having low progesterone at second GnRH. The overall percentage of cows that ovulated after second GnRH (synchronization rate) was 87% and varied by response to first GnRH (92% if ovulation to first GnRH vs 79% if no ovulation; P<0.05). There were 6% of cows that ovulated before the second injection of GnRH and 7% with no detectable ovulation by 48 h after second GnRH. Maximal diameter of the ovulatory follicle varied by stage of estrous cycle, with cows in which Ovsynch was initiated at midcycle having the smallest follicles. In addition, milk production and serum progesterone concentration on the day of PGF(2 alpha) affected (P<0.05) size of the ovulatory follicle. Using these results we analyzed pregnancy rate at Days 28 and 98 after Al for cows (n=404) in which Ovsynch was initiated on known days of the estrous cycle. Pregnancy rate was lower for cows expected to ovulate larger follicles than those expected to ovulate smaller follicles (P<0.05; 32 vs 42%). Thus, although overall synchronization rate with Ovsynch was above, 85%, there were clear differences in response according to day of protocol initiation. Cows in which Ovsynch was initiated near midcycle had smaller ovulatory follicles and greater pregnancy rates. (C) 1999 by Elsevier B.V.
Resumo:
A regimen of progesterone plus estradiol (P&E) was used as a standard for ovarian synchronization to test the efficacy and evaluate the commercial application of ultrasound-guided follicle ablation as a non-steroidal alternative for ovulation synchronization in mares. Recipient mares at a private embryo transfer facility were at unknown stages of the estrous cycle at the start of the experiment on Day 1 when they were randomly assigned to an ablation group (n = 18-21 mares) or to a ME group (n = 20-21 mares). In the ablation group, mares were lightly sedated and all follicles > 10 mm were removed by transvaginal ultrasound-guided follicle aspiration. In the ME group, a combination of progesterone (150 mg) plus estradiol (10 mg) prepared in safflower oil was given daily (im) for 10 d. Two doses of prostaglandin FZ, (PGF, 10 mg/dose, im) were given 12 h apart on Day 5 in the ablation group, or a single dose on Day 10 in the ME group. Human chorionic gonadotropin (hCG, 2500 IU/mare, im) was given at a fixed time, 6 and 10 d after PGF treatment in the ablation and ME groups, respectively, with the expectation of a follicle > 30 mm at the time of treatment. In both the ablation and P&E groups, transrectal ultrasonography was done at the start of the study (Day 1) and again on the day of hCG treatment and daily thereafter to determine the presence of a CL, measure diameter of the largest follicle and detect ovulation. The mean interval from the start of the study and from PGF treatment to ovulation was shorter (P < 0.0001) in the ablation group (13.7 and 9.7 d, respectively) compared to the P&E group (22.3 and 13.2 d, respectively). Following fixed-day treatment with hCG after PGF treatment, the degree of ovulation synchronization was not different (P > 0.05) between the ablation and P&E groups within a 2-d (56 and 70%) or 4-d (83% and 90%) period. Although ultrasound-guided follicle ablation may not be practical in all circumstances, it excluded the conventional 10-d regimen of progesterone and estradiol and was considered an efficacious and feasible, non-steroidal alternative for ovulation synchronization in mares during the estrous cycle. (C 2007 Elsevier B.V. All rights reserved.
Resumo:
This paper describes a mathematical study about chaotic system and about the unified approach of chaos control via fuzzy control system based in Linear Matrix Inequality to design a controller which synchronizes the transmission/reception system. This system, that was based in Lorenz chaotic circuit, can be used for transmit signals in secure way.
Conception rates at ET in lactating dairy recipient cows after estrous or ovulation synchronization.