78 resultados para sulfur chemiluminescence detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a measurement of the W boson mass using data corresponding to 4.3fb -1 of integrated luminosity collected with the D0 detector during Run II at the Fermilab Tevatron pp̄ collider. With a sample of 1677394 W→eν candidate events, we measure M W=80.367±0. 026GeV. This result is combined with an earlier D0 result determined using an independent Run II data sample, corresponding to 1fb -1 of integrated luminosity, to yield M W=80.375±0.023GeV. © 2012 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a search for the standard model (SM) Higgs boson produced in association with a Z boson in 9.7fb -1 of pp̄ collisions collected with the D0 detector at the Fermilab Tevatron Collider at √s=1.96TeV. Selected events contain one reconstructed Z→e +e - or Z→μ +μ - candidate and at least two jets, including at least one jet identified as likely to contain a b quark. To validate the search procedure, we also measure the cross section for ZZ production in the same final state. It is found to be consistent with its SM prediction. We set upper limits on the ZH production cross section times branching ratio for H→bb̄ at the 95% C.L. for Higgs boson masses 90≤M H≤150GeV. The observed (expected) limit for M H=125GeV is 7.1 (5.1) times the SM cross section. © 2012 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a search for the standard model Higgs boson in final states with a charged lepton (electron or muon), missing transverse energy, and two or three jets, at least one of which is identified as a b-quark jet. The search is primarily sensitive to WH→ νbb̄ production and uses data corresponding to 9.7fb -1 of integrated luminosity collected with the D0 detector at the Fermilab Tevatron pp̄ Collider at √s=1.96TeV. We observe agreement between the data and the expected background. For a Higgs boson mass of 125 GeV, we set a 95% C.L. upper limit on the production of a standard model Higgs boson of 5.2×σ SM, where σ SM is the standard model Higgs boson production cross section, while the expected limit is 4.7×σ SM. © 2012 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a measurement of the semileptonic mixing asymmetry for B0 mesons, asld, using two independent decay channels: B0→μ +D -X, with D -→K +π -π -; and B0→μ +D *-X, with D * -→D ̄0π -, D ̄0→ K +π - (and charge conjugate processes). We use a data sample corresponding to 10.4fb -1 of pp̄ collisions at √s=1.96TeV, collected with the D0 experiment at the Fermilab Tevatron collider. We extract the charge asymmetries in these two channels as a function of the visible proper decay length of the B0 meson, correct for detector-related asymmetries using data-driven methods, and account for dilution from charge-symmetric processes using Monte Carlo simulation. The final measurement combines four signal visible proper decay length regions for each channel, yielding asld=[0.68±0.45(stat)±0.14(syst)]%. This is the single most precise measurement of this parameter, with uncertainties smaller than the current world average of B factory measurements. © 2012 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A better understanding of the differential growth of upland rice (Oryza sativa L.) cultivars with increasing soil S availability could help improve rice yield under upland conditions. The objective of this study was to evaluate root and shoot growth and nutrition of upland traditional and modern rice cultivars as affected by S availability. The experimental design was completely randomized in a 3 (rates of S) × 3 (cultivars) factorial with four replications. Low availability of S in the soil reduces root and shoot development and the efficiency of N, P, and S uptake, as well as the concentration and content of these nutrients in rice cultivars. At 0 mg dm-3 of S, rice cultivars prioritize root growth over shoots, and the traditional cultivar does so with greater intensity. Our results suggested that more development of traditional cultivars under low S availability facilitates its adaptation in soils under this condition. On the other hand, the intermediate and modern cultivars are more responsive to S fertilization. Moreover, S fertilization allows significant increases in upland rice growth and must be considered in cropping systems aiming for high yields. © Soil Science Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Characterization by micro-Raman spectroscopy of polymeric materials used as nuclear track detectors reveals physico-chemical and morphological information on the material's molecular structure. In this work, the nuclear track detector poly(allyl diglycol carbonate), or Columbia Resin 39 (CR-39), was characterized according to the fluence of alpha particles produced by a 226Ra source and chemical etching time. Therefore, damage of the CR-39 chemical structure due to the alpha-particle interaction with the detector was analyzed at the molecular level. It was observed that the ionization and molecular excitation of the CR-39 after the irradiation process entail cleavage of chemical bonds and formation of latent track. In addition, after the chemical etching, there is also loss of polymer structure, leading to the decrease of the group density C-O-C (∼888 cm-1), CH=CH (∼960 cm -1), C-O (∼1110 cm-1), C-O-C (∼1240 cm -1), C-O (∼1290 cm-1), C-O (∼1741 cm -1), -CH2- (∼2910 cm-1), and the main band -CH2- (∼2950 cm-1). The analyses performed after irradiation and chemical etching led to a better understanding of the CR-39 molecular structure and better comprehension of the process of the formation of the track, which is related to chemical etching kinetics. Copyright © 2013 Society for Applied Spectroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of inclusive jet and dijet production cross sections are presented. Data from LHC proton-proton collisions at √s=7 TeV, corresponding to 5.0 fb-1 of integrated luminosity, have been collected with the CMS detector. Jets are reconstructed up to rapidity 2.5, transverse momentum 2 TeV, and dijet invariant mass 5 TeV, using the anti-k T clustering algorithm with distance parameter R=0.7. The measured cross sections are corrected for detector effects and compared to perturbative QCD predictions at next-to-leading order, using five sets of parton distribution functions. © 2013 CERN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wavelength-integrated absorbance (WIA) and summation of absorbance (∑ lines) of different lines were evaluated to enhance sensitivity and determine B, P and S in medicinal plants by HR-CS FAAS. The lowest LOD for B (0.5mgL-1) and P (13.7mgL-1) was obtained by integration of lines 249.773nm (3pixels) and 247.620nm (5pixels), respectively. The ∑ lines for CS at 257.595nm and 257.958nm furnished LOD=30.5mgL-1, ca. 10% lower than the LOD obtained for the WIA using 257.595nm and 5pixels. Data showed the advantage of WIA over ∑ lines to improve sensitivity for all analytes. Under optimized conditions, calibration curves in the 1.0-100mgL-1 B and 50.0-2000mgL-1 P, S ranges were consistently obtained. Results obtained with the HR-CS FAAS method were in agreement at 98% and 95% confidence level with certified values for B and P, respectively. And results for S were in accordance to non-certified values. Concentrations of B, P, and S in 12 medicinal plants analyzed by the proposed method varied within the 19.4-34.5mgkg-1 B, 719-3910mgkg-1 P and 1469-7653mgkg-1 S ranges. © 2012 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of searches for new resonances decaying to a pair of massive vector bosons (WW, WZ, ZZ) are presented. All searches are performed using 5.0 fb-1 of proton-proton collisions, at TeV of center of mass energy, collected by the Compact Muon Solenoid detector at the Large Hadron Collider. No significant excess compared to the standard model background expectation is observed, and upper limits at 95% confidence level are set on the production cross section times the branching fraction of hypothetical particles decaying to a pair of vector bosons. The results are interpreted in the context of several benchmark models, such as the Randall-Sundrum gravitons, the Sequential Standard Model W′, and Technicolor. Graviton resonances in the Randall-Sundrum model with masses smaller than 940 GeV/c2, for coupling parameter k/MPl = 0.05 are excluded. Bulk (ADPS) Randall-Sundrum gravitons with masses smaller than 610 GeV/c2 are excluded, for k/MPl = 0.05. Sequential Standard Model W′ with masses smaller than 1143 GeV/c2 are excluded, as well as ρTC in the 167-687 GeV/c2 mass range, in Low Scale Technicolor models with M(πTC) = 3/4 M(ρTC) - 25 GeV/c2. © 2013 IOP Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compreendida por um dispositivo para determinação do espectro de substâncias sólidas e líquidas, com possibilidades de medições in vivo, e exibindo diversas vantagens sobre os dispositivos precedentes, que apresenta uma relação sinalruído excelente e comparável a uma câmara fotoacústica com microfone convencional com a grande vantagem de ser aberta. O dispositivo é composto por um detector transparente de radiação de Tantalato de Lítio, ao qual é acoplada, por contato físico, a amostra a ser analisada. Os eletrodos do detector são em formato de anel, sendo recobertos por uma camada de óxido de índio-estanho (ITO). Ao detector deve ser acoplado um amplificador eletrónico com elevada impedância de entrada.